Extension module - PSR-M-EF8-SDI8-SDO2-DO2-PI
1105523

Safe extension module with 8 safe inputs and 2  safe outputs, 2 reset inputs, 2 signal outputs, 4 clock outputs, TBUS interface, up to SIL 3, Cat. 4/PL e, pluggable Push-in terminal block, TBUS connector included

Maksuton lataus saatavilla. Ladattavat tiedostot

Tuotetiedot


The configurable and individually scalable PSRmodular safety system is a flexible safety solution for monitoring your machine or system. The safe extension module provides the system additional safe inputs and outputs as well as signal outputs.



Product type Safety device
Application Emergency stop
Light grid
Safety door
Safe shutdown
Insulation characteristics
Protection class III
Overvoltage category II
Times
Response time see user manual
Restart time min. 5 s (Boot time)
max. 10 s (Boot time)

Maximum power dissipation for nominal condition 5.88 W (with max. permissible load)
Nominal operating mode 100% operating factor
Interfaces DIN rail TBUS for connection to the master module, supplied as standard
Rated insulation voltage 250 V AC
Rated surge voltage/insulation Basic insulation 4 kV between 24 V power supply and I/Os to the housing
Supply
Designation A1/A2
Rated control circuit supply voltage US 19.2 V DC ... 28.8 V DC
Rated control circuit supply voltage US 24 V DC -20 % / +20 % (provide external protection, typically 8 A)
Rated control supply current IS typ. 40 mA (Outputs inactive)
typ. 55 mA (Outputs active, without load)
Power consumption at US typ. 0.96 W (Outputs inactive)
Inrush current < 9 A (Δt = 1 ms at Us)
Filter time typ. 5 ms (at A1 in the event of voltage dips at Us)
Protective circuit Serial protection against polarity reversal
Suppressor diode

Digital: IN1, IN2, IN3, IN4, IN5, IN6, IN7, IN8
Description of the input Safety-related digital inputs
EN 61131-2 type 1
Number of inputs 8
Input voltage range "0" signal 0 V DC ... 5 V DC
Input voltage range "1" signal 15 V DC ... 28.8 V DC
Input current range "0" signal < 1 mA
Filter time min. 3 ms ±2 ms (adjustable)
max. 250 ms ±2 ms (adjustable)
Test pulse rate ≥ 2x set filter time, min. Test pulse rate = 10 ms
Cable length max. 100 m (per input)
Max. permissible overall conductor resistance max. 1.2 kΩ (Input and reset circuit at US)
Protective circuit Suppressor diode
Current consumption typ. 8 mA (typically with US)
max. 10 mA (at a control voltage of 28.8 V DC)
Digital: Reset inputs (FBK1, FBK2)
Description of the input IEC 61131-2 type 3
Number of inputs 2
Input voltage range "0" signal 0 V DC ... 5 V DC
Input voltage range "1" signal 11 V DC ... 28.8 V DC
Input current range "0" signal < 1 mA
Filter time 250 ms ±2 ms (Test pulse rate > 500 ms)
Cable length max. 100 m (per input)
Max. permissible overall conductor resistance 1.2 kΩ (Input and reset circuit at US)
Protective circuit Suppressor diode
Current consumption typ. 10 mA (typically with US)
max. 13 mA (at a control voltage of 28.8 V DC)

Digital: O1A, O1B, O2A, O2B
Output description Safety-related digital outputs
PNP, OSSD
IEC 61131-2 type 0.5 (observe limiting continuous current)
Number of outputs 4 (can be used as 2 two-channel outputs)
Protective circuit Suppressor diode
Short-circuit protection Yes (self-limitation at 1.1 A)
Leakage current max. 500 µA
Cable length max. 100 m (per output)
Ohmic load min. 50 Ω (Observe limiting continuous current)
Max. capacitive load max. 680 nF
Max. inductive load max. 1.4 mH
Limiting continuous current 400 mA (per channel)
1.6 A (Total current of all safe digital outputs)
Inrush current max. 750 mA (Δt  1 s)
Nominal output voltage 24 V DC (Supply via A1)
Nominal output voltage range 18 V DC ... 27.6 V DC (US - 1.2 V)
Switching frequency max. 1/4 x tCycle [Hz]
Output voltage when switched off < 1.5 V
Test pulses < 80 µs (Test pulse width of low test pulses)
Test pulse rate for low test pulses > 2 x TCycle
< 20 µs (Test pulse width, high test pulse)
≥ 1.5 s (Test pulse rate, high test pulse)
Discharging circuit Yes, internal
Signal: MO1, MO2
Output description PNP, IEC 61131-2 Typ 0,1
non-safety-related
Number of outputs 2
Output voltage when switched off max. 0.1 V
Voltage 24 V DC (via A1)
Maximum inrush current 1.1 A (Δt = 3 s  at Us)
Limiting continuous current 100 mA (per channel)
200 mA (Total current of all digital signal outputs)
Leakage current max. 100 µA
Switching frequency max. 1/4 x tCycle [Hz]
Protective circuit Suppressor diode
Short-circuit protection Yes (self-limitation at 1.1 A)
Cable length max. 100 m (per output)
Clock: T1, T2, T3, T4
Output description PNP, IEC 61131-2 type 0.5
Number of outputs 4
Voltage 24 V DC (via A1)
Output voltage when switched off max. 0.1 V
Maximum inrush current 1.1 A (Δt = 3 s  at Us)
Limiting continuous current 100 mA (per channel)
400 mA (Total current of all outputs)
Leakage current max. 100 µA
Test pulses ≤ 220 µs (Test pulse duration)
Test pulse rate = 8 x tCycle [ms]
Protective circuit Suppressor diode
Short-circuit protection Yes (self-limitation at 1.1 A)
Cable length max. 100 m (per output)
Max. capacitive load max. 470 nF
Max. inductive load max. 2.4 mH
Discharging circuit Yes, internal

Connection technology
pluggable yes
Conductor connection
Connection method Push-in connection
Conductor cross section solid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross-section AWG 24 ... 16
Stripping length 10 mm

Status display 1 x LED (green), 2 x LED (orange)
12 x LED (yellow)
2 x LED (green, red)
Operating voltage display 1 x green LED
Error indication 2 x LED (red)

Width 22.61 mm
Height 107.74 mm
Depth 113.6 mm

Housing material Polyamide PA non-reinforced

Safety data
Stop category 0
Safety data: EN ISO 13849
Performance level (PL) e (2-channel wiring)
d (1-channel wiring)
Safety data: IEC 61508 - High-demand for 2-channel wiring
Equipment type Type B
Safety Integrity Level (SIL) 3
Probability of a hazardous failure per hour (PFHD) 5.67 x 10-9
Proof test interval 240 Months
Duration of use 240 Months
Integrity requirement IEC 61508 - High-demand for 1-channel wiring
Equipment type Type B
Safety Integrity Level (SIL) 2
Probability of a hazardous failure per hour (PFHD) 5.67 x 10-9
Proof test interval 240 Months
Duration of use 240 Months

Ambient conditions
Degree of protection IP20
Min. degree of protection of inst. location IP54
Ambient temperature (operation) -10 °C ... 55 °C (observe derating)
Ambient temperature (storage/transport) -20 °C ... 85 °C
Maximum altitude ≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport) 95 % (non-condensing)
Max. permissible relative humidity (operation) 95 % (non-condensing)
Shock 10g for Δt = 16 ms (continuous shock, 1000 shocks in each space direction)
Vibration (operation) 10 Hz ... 150 Hz, 2g

CE
Certificate CE-compliant

Mounting type DIN rail mounting
Assembly instructions Observe derating
Mounting position vertical or horizontal

Tuotenumero 1105523
Pakkausyksikkö 1 Kappaletta
Vähimmäistilausmäärä 1 Kappaletta
Tuoteavain DNA362
Tuotekoodi DNA362
GTIN 4055626988313
Paino kappaletta kohti (sis. pakkauksen) 176,5 g
Paino kappaletta kohti (ilman pakkausta) 141 g
Tullitariffinumero 85371098
Alkuperämaa IT


ECLASS

ECLASS-9.0 27371819
ECLASS-10.0.1 27371819
ECLASS-11.0 27371819

ETIM

ETIM 8.0 EC001449

UNSPSC

UNSPSC 21.0 39122200

UL Listed

Hyväksyntätunnus: FILE E 238705

cUL Listed

Hyväksyntätunnus: FILE E 238705

EAC

Hyväksyntätunnus: RU*-DE*B.00606/20

Functional Safety

Hyväksyntätunnus: Z10 029429 0013

cULus Listed


China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Yhteensopivat tuotteet



Edut

Cost-effective safety solution with a high level of adaptability to individual requirements
Fast startup, thanks to easy hardware and software configuration
Machine downtimes minimized with comprehensive, easy-to-understand diagnostics
Tool-free and time-saving installation thanks to Push-in technology
Narrow housing width of just 22.6 mm
Up to Cat. 4/PL e in accordance with ISO 13849-1, SIL 3 in accordance with IEC 62061, SIL 3 in accordance with IEC 61508
Suitable for elevator applications in accordance with EN 81-20