Termination board - IBS PCI SC/I-T
2725260

PCI master controller board with electrical isolation

Downloads

Detalii despre produs




Notes on operation From item revision 15, the controller board will no longer be equipped with a NVRAM (Non-Volatile Random-Access-Memory) due to component discontinuation.
The fundamental functionality of the controller board is not affected. In applications that access the NVRAM, applicative countermeasures will have to be taken.
Utilization restriction
EMC note EMC: class A product, see manufacturer's declaration in the download area

Type PC card
Product type PC controller board
Set comprises 2732981 IBS PCI SC SYSKIT
2732994 IBS PCI SC SYSKIT E
Format Short plug-in card, 1-slot

Local diagnostics SC, HF, PF, BSA, FAIL INTERBUS Status display via LED
Transmission medium Copper
Maximum power dissipation for nominal condition max. 3.5 W
Supply
Supply voltage 5 V DC
Supply voltage range ± 5 % (including ripple)
Power supply connection Via PCI bus
Typical current consumption 0.7 A

Digital
Input name Digital inputs
Number of inputs 6 (EN 61131-2 type 1)
Connection technology FLK cable connector (14-pos.)
Nominal input voltage UIN 24 V DC

Digital
Output name Digital outputs
Connection technology FLK cable connector (14-pos.)
Number of outputs 2
Output voltage 24 V DC
Maximum output current per channel 0.5 A

Interrupts 1 IRQ, PnP
INTERBUS remote bus
Connection method 9-pos. D-SUB female connector, with electrical isolation
Transmission speed 500 kbps
Parameterization/operation/diagnostics
Connection method RS-232-C, Mini-DIN female
Transmission speed 500 kbps500 kbps 2 Mbps
Host system
Connection method PCI bus, 32 bit, 33 MHz, 5 V
Direct I/Os
Connection method 14-pos. FLK pin strip

Control system IBM-compatible PCs with PCI slot
Operating system Windows NT
Windows 2000
Windows XP
Windows 7 (64 bit)
Windows 8/10 (32 & 64 bit)
Venturcom RTX 5.x
Further types on request
Addressable areas
I/O 16 bytes I/O, PnP
INTERBUS-Master
Number of devices with parameter channel max. 126
Local diagnostics
Designation SC, HF, PF, BSA, FAIL
Monitored function INTERBUS
Optical representation Status display via LED

Functionality
Control system IBM-compatible PCs with PCI slot
System requirements
Configuration tool CMD from version 4.5x
Config+ from version 1.00 onwards
Diagnostics tool DIAG+ from version 1.0x
Application interface HFI
DDI
Driver Windows NT
Windows 2000
Windows XP
Windows 7 (64 bit)
Windows 8/10 (32 & 64 bit)
Venturcom RTX 5.x
Further types on request

Width 168 mm
Height 107 mm
Depth 20 mm
External dimensions
Width / Height / Depth 168 mm / 107 mm / 20 mm

Ambient conditions
Degree of protection IP20 (Must be installed in a device with IP20)
Ambient temperature (operation) 0 °C ... 55 °C (acc. to EN 60204-1)
Ambient temperature (storage/transport) -25 °C ... 75 °C (acc. to EN 60204-1)
Permissible humidity (operation) 75 % (on average, 85% infrequently, non-condensing)
Air pressure (operation) 860 hPa ... 1080 hPa (up to 2000 m above sea level)
Air pressure (storage/transport) 660 hPa ... 1080 hPa (up to 3000 m above sea level)

Mounting type In the host system

Număr articol 2725260
Unitate de ambalare 1 Bucată
Cantitate minimă pentru comandă 1 Bucată
Cod produs DREABA
Pagina de catalog Pagina 54 (C-6-2019)
GTIN 4017918185121
Greutate pe bucată (inclusiv ambalajul) 166,2 g
Greutate pe bucată (fără ambalaj) 126,1 g
Cod tarifar vamal 84733020
Țara de origine DE


ECLASS

ECLASS-9.0 27242208
ECLASS-10.0.1 27242208
ECLASS-11.0 27242208

ETIM

ETIM 8.0 EC001423

UNSPSC

UNSPSC 21.0 32151700

cUL Recognized

ID de înregistrare: FILE E 140324

UL Recognized

ID de înregistrare: FILE E 140324

cULus Recognized


REACh SVHC Lead 7439-92-1
Hexahydromethylphthalic anhydride
China RoHS Environmentally Friendly Use Period = 50 years
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads”

Avantajele dumneavoastră

Access to high-level language applications via HFI
INTERBUS parameter channel (PCP) supported
Access to INTERBUS system data and controller data via visualization stations
Compatible driver
Parameterization and diagnostics with Diag+
Installation of several cards in a PC with monitoring of multiple INTERBUS lines
External 24 V DC power supply