AC charging controller - EV-CC-AC1-M3-CBC-RCM-ETH
1018701

AC charging controller in accordance with IEC 61851-1, client or stand-alone, Modbus/TCP via Ethernet, connection for RFID reader and energy meter via RS-485, DC residual current monitoring, connector release in the event of power failure

Descărcare gratuită disponibilă. Descărcări

Detalii despre produs


Mode 3 controller for charging electric vehicles in accordance with IEC 61851-1 for charging case B and C with integrated DC residual current monitoring and Ethernet communication interface.



Product type AC charging controller
Application AC charging controller for private and commercial applications (EU/CN)
Operating mode Stand-Alone
Client
Charging mode Mode 3, Case B + C
Insulation characteristics
Overvoltage category II

Type of charging current AC
Current consumption < 3 W (No-load)
Power consumption < 10 W
Locking release in the event of mains failure Integrated release function of the locking actuator for disconnection of Infrastructure Plug and Infrastructure Socket Outlet
Measuring current transducer
Connection method Connector
Diameter of measuring coil 15 mm
Measuring range: Residual current
Rated frequency fn ≤ 2000 Hz
Nominal differential current ± 300 mA
Residual current IΔn 30 mA (AC)
6 mA (DC)
Rated current In 32 A (Three-phase, 4x6 mm²)
48 A (Single-phase)
Tripping time for IΔn < 180 ms
Response time for 2 x IΔn < 70 ms
Tripping time for 5xIΔn < 20 ms
Supply
Supply voltage 230 V
Supply voltage range 100 V AC ... 240 V AC (nominal voltage range)
Nominal power consumption < 3 W (No-load)
Power consumption < 10 W (maximum)
Frequency range 50 Hz ... 60 Hz

Digital
Number of digital inputs 5
Description of the input Digital input
Nominal current IN ≤ 4 mA
Nominal input voltage UN 12 V
Input voltage range 0 V ... 3 V (Off)
Input voltage range U2 9 V ... 15 V (On)

Digital
Output name 4 digital outputs
Connection technology Screw connection
Maximum output voltage 30 V
Maximum output current 0.2 A (Total current for all outputs; internally supplied)
Maximum output current per channel 0.6 A (Per output; externally supplied)
Switching
Output name Relay output C1.2
Minimum switching capacity 4000 VA
Maximum switching voltage 250 V AC (External supply)
Max. switching current 16 A
Switching
Output name Motor switching output
Maximum switching voltage 12 V (Internal supply)
Max. switching current 1 A (maximum)

Conductor connection
Connection method Screw connection
Conductor cross section solid 0.2 mm² ... 4 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 12
Conductor connection
Connection method Screw connection
Conductor cross section solid 0.14 mm² ... 1.5 mm²
Conductor cross section flexible 0.2 mm² ... 1 mm²
Conductor cross section AWG 26 ... 16

Interface Ethernet (1x)
RS-485
Interface RS-485 2-wire
Bus system RS-485
Connection method Screw connection
Number of interfaces 1 (for energy measurement device and RFID reader)
Number of supported devices 2
Transmission speed range 4.8 kbps ... 115.2 kbps (adjustable)
Protocols supported Modbus/RTU (Master)
RS-485
Interface Ethernet
Connection method RJ45 jack
Number of interfaces 1
Serial transmission speed 10/100 Mbps
Transmission length 100 m
Protocols supported Modbus/TCP

Charging controllers
Number of charging points 1

Status display 5x LEDs

Desen dimensional
Width 162 mm
Height 90 mm
Depth 61.00 mm

Ambient conditions
Degree of protection IP20
Ambient temperature (operation) -25 °C ... 60 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Altitude < 2000 m
Permissible humidity (operation) 30 % ... 95 % (non-condensing)

Conformity/Approvals
Conformance CE-compliant

Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Housing DIN 43880
Noise emission EN 61000-6-3
Noise immunity EN 61000-6-2
Immunity to the discharge of static electricity EN 61000-4-2: 8 kV air, 4 kV contact discharge
Immunity to electromagnetic fields EN 61 000-4-3, 80---1000 MHz, 10 V/m
Immunity to conducted high frequency EN 61 000-4-6, 0.15...80 MHz, 10 V
Immunity to fast transients (Burst) EN 61 000-4-4: 2 kV AC mains input, 1 kV data cable

Standards
Standards/regulations IEC 61851-1

Mounting type DIN rail mounting
Mounting position any

Număr articol 1018701
Unitate de ambalare 1 Bucată
Cantitate minimă pentru comandă 1 Bucată
Cod produs XWBBCA
Pagina de catalog Pagina 60 (C-7-2019)
GTIN 4055626503691
Greutate pe bucată (inclusiv ambalajul) 538,3 g
Greutate pe bucată (fără ambalaj) 538,3 g
Cod tarifar vamal 85371098
Țara de origine DE


ECLASS

ECLASS-9.0 27144703
ECLASS-10.0.1 27144703
ECLASS-11.0 27144703

ETIM

ETIM 8.0 EC002889

UNSPSC

UNSPSC 21.0 39121800

China RoHS Environmentally Friendly Use Period = 50 years
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads”