The DALI extension module supplements the Catan product family with a powerful lighting control system for 4 independent DALI lines. It supports the DALI-2 standard including multi-master function for integrating DALI sensors. It has an integrated bus power supply. The DiiA certification guarantees compatibility with all certified DALI products. It also offers 8 digital outputs, which can alternatively be used for the digital input or counter function. The device is Cradle to Cradle Certified® at bronze level.
CATAN DALI MM4 DOI8
-
Data interface
1371363
Extension module for Catan controller. 4 DALI lines, DALI-2, multi-master, integrated DALI power supply unit, 8 DOIs. Local override operation via Catan Control Panel. Connection to the Catan controller via Single Pair Ethernet.
Докладно про виріб
| Dimensions without display connected | |
| Width | 89.7 mm |
| Height | 60.7 mm |
| Length | 107.6 mm |
| Horizontal pitch | 6 Div. (DIN rail housing in accordance with DIN 43871) |
| Dimensions with display connected | |
| Width | 89.7 mm |
| Height | 68 mm |
| Length | 107.6 mm |
| Note on application | |
| Note on application | Only for industrial use |
| Number of interfaces | 4 |
| Connection method | Push-in connection |
| Fieldbus: DALI | |
| Designation | DALI |
| No. of channels | 4 |
| Supply voltage | typ. 16 V DC (Bus voltage) |
| Output current | 230 mA (guaranteed) |
| 250 mA (maximum) | |
| Current carrying capacity | max. 190 mA (per channel) |
| Transmission speed | 1200 bps |
| Type of protection | Bus protected up to 250 V AC, maximum |
| Extension bus (link bus) | |
| Number of interfaces | 2 (for extension modules) |
| Connection method | Push-in connection |
| Note on the connection method | Single Pair Ethernet (SPE) 10BASE-T1L, shielded |
| Transmission speed | 10 Mbps |
| Transmission length | max. 350 m (between two devices) |
| Connection for Catan Control Panel | |
| Number of interfaces | 1 |
| Connection method | USB 2.0 full speed, socket type C |
| Transmission speed | max. 12 Mbps |
| Digital: Digital input (DOI) | |
| Input name | “Digital input” function |
| Input information | Connect the contact to ground. |
| Recommendation: If you use sensitive contacts such as reed contacts, connect a series resistor of at least 100 Ω in series. | |
| Connection method | Push-in connection |
| Connection technology | 2-conductor |
| Input current (Contact) | 1 mA |
| Input resistance range (“0” signal) | > 27 kΩ |
| Input resistance range (“1” signal) | < 1 kΩ |
| Counter: Digital input (DOI) | |
| Input name | Counter inputs |
| Input frequency | max. 100 Hz |
| Resolution | 1 Impulse |
| Digital: Digital output (DOI) | |
| Output name | Digital outputs with “Digital input” function (DOI) |
| Note on output | To obtain a valid voltage level for a logical "0" signal at the output, use a load resistor <1 kΩ. |
| You can parameterize each digital output for the “Digital input” function. | |
| Connection method | Push-in connection |
| Connection technology | 2-conductor |
| Number of outputs | 8 |
| Protective circuit | Short-circuit protection |
| Overload protection | |
| Protection against incorrect DC connection (max. 30 V) | |
| Output current | max. 500 mA |
| Observe derating! Sum of the output currents up to 45°C: 4 A, derating up to 50°C: reduction by 0.2 A per Kelvin | |
| Nominal output voltage | 24 V DC |
| Output current when switched off | max. 1.4 mA |
| Nominal load, ohmic | 12 W (48 Ω) |
| Permissible cable length | max. 30 m (For compliance with the requirements in accordance with CE and to ensure compliance with the EMC Directive) |
| Reverse voltage resistance to short pulses | Reverse voltage proof |
| Behavior with overload | Auto restart |
| Behavior at voltage switch-off | The output follows the power supply without delay |
| Product family | Catan |
| Installation location | indoor use |
| Mounting position | horizontal |
| Alternative mounting positions are possible, but can lead to a reduction in thermal performance. | |
| Special properties | Multi-master-capable |
| Insulation characteristics | |
| Overvoltage category | II (IEC 60664-1, EN 60664-1) |
| Pollution degree | 2 (IEC 60664-1, EN 60664-1) |
| Supply: | |
| Designation | Supply |
| Supply voltage | 24 V DC |
| Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Current consumption | max. 5.1 A |
| Please refer to the “Additional data” section in the data sheet. | |
| Electrical isolation/isolation of the voltage ranges | |
| Test voltage: Extension bus/communications | 500 V AC, 50 Hz, 1 min |
| Test voltage: Logic/functional ground | 500 V AC, 50 Hz, 1 min |
| Test voltage: | 500 V AC, 50 Hz, 1 min |
| Test voltage: | 1.5 kV AC, 50 Hz, 1 min |
| Test voltage: DALI/functional ground | 1.5 kV AC, 50 Hz, 1 min |
| Test voltage: | 1.5 kV AC, 50 Hz, 1 min |
| Connection technology | |
| Connection name | Connections 1 ... 19 (DALI) |
| Connections 1 ... 19 (DALI) | |
| Connection method | Push-in connection |
| Conductor cross-section, rigid | 0.2 mm² ... 4 mm² (Conductor connection with open terminal point) |
| 0.5 mm² ... 4 mm² (Push-in connection) | |
| Conductor cross-section, flexible | 0.2 mm² ... 4 mm² |
| Conductor cross-section AWG | 24 ... 12 |
| Conductor cross-section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 2.5 mm² |
| Conductor cross-section, flexible, with ferrule, without plastic sleeve | 0.25 mm² ... 2.5 mm² |
| 0.25 mm² ... 2.5 mm² | |
| Conductor cross-section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 2.5 mm² |
| Nominal cross section | 4 mm² |
| Stripping length | 10 mm |
| Connections 31 ... 62 (power supply, link bus, digital outputs) | |
| Connection method | Push-in connection |
| Conductor cross-section, rigid | 0.2 mm² ... 1.5 mm² (Conductor connection with open terminal point) |
| 0.34 mm² ... 1.5 mm² (Push-in connection) | |
| Conductor cross-section, flexible | 0.5 mm² ... 1.5 mm² |
| Conductor cross-section AWG | 24 ... 16 |
| Conductor cross-section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 1.5 mm² |
| Conductor cross-section, flexible, with ferrule, without plastic sleeve | 0.25 mm² ... 1.5 mm² |
| 0.25 mm² ... 1.5 mm² | |
| Conductor cross-section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 1.5 mm² |
| Nominal cross section | 1.5 mm² |
| Stripping length | 10 mm |
| Ambient conditions | |
| Ambient temperature (operation) | -5 °C ... 50 °C (up to 3000 m above mean sea level) |
| Degree of protection | IP20 |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 58 kPa ... 106 kPa (up to 4500 m above mean sea level) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
| Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
| Mounting type | DIN rail mounting (in accordance with DIN EN 60715) |
| Mounting position | horizontal |
| Артикул | 1371363 |
| Пакувальна одиниця | 1 Шт. |
| Мінімальний обсяг замовлення | 1 Шт. |
| Код виробу | DRHAFA |
| GTIN | 4063151727895 |
| Країна походження | Інформація про країну походження надається разом з доставкою. |
ECLASS
| ECLASS-13.0 | 27242604 |
| ECLASS-15.0 | 27242604 |
ETIM
| ETIM 9.0 | EC001599 |
Сумісна продукція
Переваги
Space and cost savings thanks to highly flexible I/O configurability
Integration of a large number of DALI devices (max. 256 ballasts and 252 sensors)
Startup and maintenance with plug-in display for local operation
High-performance extension bus also enables distributed installation