FL SWITCH APL 2212-4A-221
-
Industrial Ethernet Switch
1718554
12-Port Ethernet-APL Field switch, Zone 2 mountable, Ex ‘ic’ APL ports, four uplink ports, Power Class A ports
Transferência gratuita disponível.
Downloads
Detalhes dos produtos
| Dimensional drawing |
|
| Width | 150 mm |
| Height | 215 mm |
| Depth | 127 mm |
| Note on dimensions | Depth when installed on a NS 35/15 DIN rail |
| Note on application | |
| Note on application | Only for industrial use |
| Utilization restriction | |
| EMC note | EMC: class A product, see manufacturer's declaration in the download area |
| Housing material | Die-cast aluminum |
| PC |
| Mounting type | DIN rail mounting |
| Panel mount | |
| Useable DIN rail type | NS 35/15 |
| NS 35/15 |
| Ethernet (RJ45) | |
| Number of interfaces | 2 |
| Connection method | RJ45 |
| Note on the connection method | Auto negotiation and autocrossing |
| Transmission speed | 10/100 Mbps |
| Transmission physics | Copper |
| Transmission length | 100 m (per segment) |
| Signal LEDs | Data receive, link status |
| No. of channels | 2 (RJ45 ports) |
| Ethernet (SFP) | |
| Number of interfaces | 2 |
| Connection method | SFP |
| Note on the connection method | Full duplex |
| Transmission speed | 100/1000 Mbps (full duplex) |
| Transmission physics | FO |
| Transmission length | Depending on the SFP module used |
| No. of channels | 2 (SFP ports) |
| Ethernet (APL) | |
| Connection method | Screw connection |
| Note on the connection method | APL, full duplex |
| Transmission speed | 10 Mbps |
| Transmission physics | Copper |
| No. of channels | 12 (APL ports) |
| Power Source Equipment (PSE) Port: Class A | |
| Power Class | SPAA |
| Note | Each port configurable via software |
| Output nominal voltage | ≥ 9.6 V DC |
| Output current | ≥ 55.56 mA |
| Output power | ≥ 0.54 W |
| Product type | Switch |
| MTTF | 83.26 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
| 42.17 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) | |
| 10.29 Years (SN 29500 standard, temperature 55°C, operating cycle 100%) | |
| Special properties | Zone 2 mountable |
| Ex ‘ic’ APL ports | |
| four uplink ports | |
| Insulation characteristics | |
| Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
| Overvoltage category | II |
| Degree of pollution | 2 |
| Switch functions | |
| Diagnostic functions | RMON History |
| LLDP (Link Layer Discovery Protocol) | |
| SNMP-Traps | |
| N:1-Portmirroring | |
| ACD (Address Conflict Detection) | |
| SysLog | |
| CRC-Surveillance | |
| Filter functions | Quality of Service (8 priority classes) |
| Class of Service | |
| DiffServ/DSCP | |
| Port prioritization | |
| VLAN (up to 32 VLANs) | |
| IGMP Snooping/Querier (v1/v2) | |
| Auto-Query-Port | |
| Extended Multicast Filtering | |
| IP parameterization | DHCP client |
| DHCP Option 82 (Relay Agent) | |
| DHCP server (pool-based, port-based) | |
| BootP | |
| DCP (Discovery and Configuration Protocol) | |
| MAC address table | 8k |
| Management | Web-based management (HTTP/HTTPS) |
| Role-based user management (LDAP, RADIUS) | |
| SNMPv1/v2/v3 | |
| Redundancy | MRP (Media Redundancy Protocol) |
| RSTP (Rapid Spanning Tree Protocol) | |
| Large Tree Support | |
| LACP (Link Aggregation Control Protocol) | |
| PROFINET S2 system redundancy | |
| Time synchronization | SNTP (Simple Network Time Protocol) |
| Power consumption | 8 W (No-load) |
| max. 20.9 W (12 Class A ports at max. load (22 V DC supply voltage at 70°C)) | |
| Maximum power dissipation for nominal condition | 14 W (12 Class A ports at max. load (22 V DC supply voltage at 70°C)) |
| Test section | Supply Voltage/spurs 1500 V ACrms |
| 100BASE-T / Spurs 1500 V ACrms | |
| SFP / Spurs 1500 V ACrms | |
| Spurs / Earth Ground (Housing) 500 V ACrms | |
| Block of Spurs / Block of Spurs 500 V ACrms | |
| Supply / 100BASE-T 2000 V ACrms | |
| 100BASE-T / 100BASE-T 2000 V ACrms | |
| Supply / SFP 1500 V ACrms | |
| Supply | |
| Supply voltage (DC) | 24 V DC (redundant) |
| Supply voltage range | 22 V DC ... 30 V DC (redundant) |
| Max. current consumption | 1 A |
| Power supply | |
| Connection method | Screw connection |
| pluggable | yes |
| Conductor cross-section, rigid | 0.2 mm² ... 2.5 mm² |
| Conductor cross-section, flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross-section AWG | 24 ... 12 |
| Stripping length | 7 mm |
| Ambient conditions | |
| Degree of protection | IP20 |
| Ambient temperature (operation) | -40 °C ... 70 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Altitude | 2000 m (maximum) |
| Permissible humidity (operation) | 0 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
| Shock (operation) | 15g (IEC 600868-2-27) |
| Vibration (operation) | 1g, according to EN 60068-2-6 |
| ATEX | |
| Identification | II 3(3)G Ex ic ec [ic] IIC T4 Gc |
| II (3) D [Ex ic Dc] IIIC | |
| Certificate | U 25 ATEX 3482X |
| IECEx | |
| Identification | Ex ic ec [ic] IIC T4 Gc |
| [Ex ic Dc] IIIC | |
| Certificate | IECEx UL 25.0071X |
| UL, USA/Canada | |
| Identification | Ind. Cont. Eq. E238705 also Listed |
| Ind. Cont. Eq. for haz. loc. E196811 | |
| Install in: Class I, Div. 2, Groups A, B, C, D T4 | |
| Nonincendive field wiring outputs for: Class I, Div. 2, Groups A, B, C, D; Class II, Div. 2, Groups F, G; Class III, Div. 2 haz. loc. | |
| Class I, Zone 2, AEx ic ec [ic] IIC T4 Gc, [AEx ic Dc] IIIB | |
| Ex ic ec [ic] IIC T4 Gc X | |
| [Ex ic Dc] IIIC X | |
| CCC Ex | |
| Identification | Ex ic ec [ic] IIC T4 Gc |
| [Ex ic Dc] IIIC | |
| INMETRO | |
| Identification | Ex ic ec [ic] IIC T4 Gc |
| [Ex ic Dc] IIIC | |
| Certificate | DNV 26.0115 X |
| Safety data | |
| Max. output voltage Uo | 13.23 V |
| Max. output current Io | 341.6 mA |
| Max. output power Po | 1.23 W |
| Safety-related maximum voltage Um | 60 V |
| IIC: Max. external inductivity Lo / Max. external capacitance Co | 0.14 mH / 0.5 µF |
| IIB/IIIB: Max. external inductivity Lo / Max. external capacitance Co | 1.2 mH / 1.5 µF |
| IIA: Max. external inductivity Lo / Max. external capacitance Co | 2.39 mH / 1.8 µF |
| Safety data | |
| IIC: Max. external inductivity Lo / Max. external capacitance Co | 0.14 mH / 0.5 µF |
| IIB, IIIC/IIIB: Max. external inductivity Lo / Max. external capacitance Co | 1.2 mH / 1.5 µF |
| IIA: Max. external inductivity Lo / Max. external capacitance Co | 2.39 mH / 1.8 µF |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU (Test requirements for NE 21, IEC 61326-7 also considered as per the APL EMC specifications) |
| Conformance with EMC directives | EN 61000-6-2 EN 61000-4-2 (ESD) Criterion A, ±6 kV contact discharge, ±8 kV air discharge |
| EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion A, Field intensity: 10 V/m | |
| EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A, supply lines: ±2 kV, signal/data lines: ±1 kV | |
| EN 61000-6-2 EN 61000-4-5 (surge) Criterion A, ±1 kV supply line L-PE; ±1 kV supply line N-PE; ±1 kV shielded I/O signal lines for metallic enclosure devices | |
| EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A, 10 Vrms | |
| EN 61000-6-2 IEC 61000-4-16 (common mode disturbances) Criterion A: 10V (10 kHz to 150 kHz) | |
| EN 61000-6-4 EN 55011 (emitted interference) Class A | |
| Noise immunity | EN 61000-6-2 |
| Noise emission | |
| Standards/regulations | EN 61000-6-4 |
| N.º de artigo | 1718554 |
| Pcs./Emb | 1 Unidade |
| Quantidade mínima de pedido | 1 Unidade |
| Chave comercial | DNN |
| Chave de produto | DNN128 |
| GTIN | 4067923269330 |
| Peso por unidade (inclusive embalagem) | 2 473 g |
| Peso por unidade (excluindo embalagem) | 2 177,4 g |
| Número do imposto alfandegário | 85176200 |
| País de origem | US |
ECLASS
| ECLASS-13.0 | 19170401 |
| ECLASS-15.0 | 19170401 |
ETIM
| ETIM 10.0 | EC000734 |
| EU RoHS | |
| Cumpre os requisitos de substância segundo a Diretiva RoHS | Sim |
| isenções tanto quanto conhecido | 6(c), 7(a), 7(c)-I |
| China RoHS | |
| Environment friendly use period (EFUP) |
EFUP-10
Uma lista de declaração de acordo com a RoHS da China relativa a artigos encontra-se na área de transferências do respetivo artigo, em "Declaração do fabricante". Para todos os artigos com EFUP-E não é emitida nem necessária uma tabela de declaração de acordo com a RoHS da China.
|
| EU REACH SVHC | |
| Nota sobre as substâncias candidatas ao REACH (n.º CAS) | Lead (n.º CAS: 7439-92-1) |
| 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol (n.º CAS: 79-94-7) | |
Produtos compatíveis
-
DT-LAN-CAT.6+ - Surge protection device 2881007
-
E/NS 35 N - End bracket 0800886
-
FL SFP FX - Media module 2891081
-
FL SFP LX - Media module 2891767
-
FL SFP SX - Media module 2891754
-
FL SFP SX2 - Media module 2702397
-
FL SFP FX SM - Media module 2891082
-
FL SFP FE WDM20-A - Media module 2702437
-
TTC-6P-3-APL-24DC-UT-I - Surge protection device 1635592
-
TTC-6P-3-APL-EX-24DC-UT-I - Surge protection device 1635587
Vantagens
Redundant power connections
APL-managed switch
Top-down wiring terminations
PROFINET-managed switch
Connects to Ex ic devices in Zone 2 hazardous locations using 2-WISE, FISCO, or intrinsically safe entity parameters
Global approvals
MRP and S2 PROFINET System Redundancy
Pesquisado com frequência
Phoenix Contact S.A.
Sintra Business Park, Edifício n°1 Zona Industrial da Abrunheira, sala 0M, 2710-089 SINTRA