The terminal is designed for use within an Inline station. It provides a 24 V supply voltage to the main circuit (UM) and automatically supplies power for the 24 V segment circuit (US). The terminal has protection against polarity reversal and surge voltage. The internal fuse protects the main and segment circuits. This terminal has an LED for bus diagnostics. It occupies two input data bits, which indicate the availability of the supply voltage and the status of the fuse.
IB IL 24 PWR IN/2-F-D-PAC
-
Feed-in module
2862152
Inline power terminal block, complete with accessories (connector and labeling field), 24 V DC, with fuse (Main and segment voltage) and diagnostics
Transferência gratuita disponível.
Downloads
Detalhes dos produtos
Dimensional drawing |
|
Width | 12.2 mm |
Height | 119.8 mm |
Depth | 71.5 mm |
Note on application | |
Note on application | Only for industrial use |
Utilization restriction | |
CCCex note | Use in potentially explosive areas is not permitted in China. |
Inline local bus | |
Number of interfaces | 2 |
Connection method | Inline data jumper |
Transmission speed | 500 kbps |
Module | |
ID code (dec.) | 190 |
ID code (hex) | BE |
Length code (hex) | C2 |
Length code (dec) | 194 |
Process data channel | 2 bit |
Input address area | 2 bit |
Output address area | 0 bit |
Register length | 2 bit |
Required parameter data | 1 Byte |
Required configuration data | 4 Byte |
Product type | I/O component |
Product family | Inline |
Type | modular |
Number of plugs | 1 |
Operating mode | Process data mode with 2 bits |
Special properties | 24 V DC |
UM, US | |
With fuse (UM, US) | |
With diagnostics | |
Insulation characteristics | |
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Maximum power dissipation for nominal condition | 0.7 W |
Test section | 7.5 V supply (bus logics)/24 V supply (I/O) 500 V AC 50 Hz 1 min |
24 V supply (I/O) / functional ground 500 V AC 50 Hz 1 min | |
7.5 V supply (bus logic)/functional ground 500 V AC 50 Hz 1 min | |
Protective circuit | Surge protection; Suppressor diode |
Reverse polarity protection; Parallel polarity protection diode | |
Overload protection, short-circuit protection in the main and segment circuits; Fuse 5x20 with 6.3 A slow-blowFuses with other values can also be used. The maximum fuse value is 6.3 A.For fuses with a value greater than 2 A, only slow-blow fuses may be used. | |
Fuse | SI 5 x 20 6, 300 AT (in scope of delivery) |
Supply | |
I/O voltage | 24 V DC |
I/O voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Residual ripple | ± ±5 % |
Max. current consumption | 4 A |
Typical current consumption | 30 mA |
Potentials: Communications power (UL) | |
Supply voltage | 7.5 V DC (via voltage jumper) |
Current draw | max. 25 mA |
Power consumption | max. 0.19 W |
Potentials: Main circuit supply (UM) | |
Supply voltage | 24 V DC (via Inline connector) |
Supply voltage range | 19.2 V ... 30 V (including all tolerances, including ripple) |
Current draw | typ. 4 A (nominal value) |
Potentials: Segment circuit supply (US) | |
Supply voltage | 24 V DC |
Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw | typ. 4 A (nominal value) |
Connection technology | |
Connection name | Inline connector |
Conductor connection | |
Connection method | Spring-cage connection |
Conductor cross section rigid | 0.08 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.08 mm² ... 1.5 mm² |
Conductor cross section AWG | 28 ... 16 |
Stripping length | 8 mm |
Inline connector | |
Connection method | Spring-cage connection |
Conductor cross section, rigid | 0.08 mm² ... 1.5 mm² |
Conductor cross section, flexible | 0.08 mm² ... 1.5 mm² |
Conductor cross section AWG | 28 ... 16 |
Stripping length | 8 mm |
Ambient conditions | |
Degree of protection | IP20 |
Ambient temperature (operation) | -25 °C ... 55 °C |
Ambient temperature (storage/transport) | -25 °C ... 85 °C |
Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Mounting type | DIN rail mounting |
N.º de artigo | 2862152 |
Pcs./Emb | 1 Unidade |
Quantidade mínima de pedido | 1 Unidade |
Chave comercial | DRI |
Chave de produto | DRI121 |
GTIN | 4017918894641 |
Peso por unidade (inclusive embalagem) | 88,633 g |
Peso por unidade (excluindo embalagem) | 44 g |
Número do imposto alfandegário | 85389099 |
País de origem | DE |
ECLASS
ECLASS-13.0 | 27242610 |
ETIM
ETIM 9.0 | EC001600 |
UNSPSC
UNSPSC 21.0 | 32151600 |
EU RoHS | |
Cumpre os requisitos de substância segundo a Diretiva RoHS | Sim |
isenções tanto quanto conhecido | 7(a), 7(c)-I |
China RoHS | |
Environment friendly use period (EFUP) |
EFUP-50
Uma lista de declaração de acordo com a RoHS da China relativa a artigos encontra-se na área de transferências do respetivo artigo, em "Declaração do fabricante". Para todos os artigos com EFUP-E não é emitida nem necessária uma tabela de declaração de acordo com a RoHS da China.
|
EU REACH SVHC | |
Nota sobre as substâncias candidatas ao REACH (n.º CAS) | Lead (n.º CAS: 7439-92-1) |
SCIP | 1fabced0-b1d9-4502-81ef-7b6b98b7e70e |
Produtos compatíveis
Vantagens
Supply of the 24 V main voltage UM
Provision of the 24 V segment voltage US
Main and segment circuits protected by an internal fuse