Special function module - AXL SE INC1 ASYM
1182185

Axioline Smart Elements, Position detection module, Incremental encoder input: 1, Asymmetrical encoder, Digital inputs: 2, 24 V DC, degree of protection: IP20

Este produto precisa de outros produtos para a operação. Acessórios necessários

Detalhes dos produtos


You can integrate Axioline Smart Elements into systems with the Smart Element interface. This Smart Element detects the positions of incremental encoders.



Desenho cotado
Width 14.9 mm
Height 62.2 mm
Depth 62 mm

Utilization restriction
EMC note EMC: class A product, see manufacturer's declaration in the download area

Color traffic grey A RAL 7042

Smart Element interface
No. of channels 1
Connection method Card edge connector
Transmission speed See system in which you use the Smart Element.
Start time until ready to operate < 500 ms

Module
ID code (hex) none

Digital
Input name Digital inputs
Description of the input EN 61131-2, type 3
Number of inputs 2 (DI Ref, DI L)
Connection method Push-in connection
Connection technology 1-conductor
Input voltage range "0" signal -3 V DC ... 5 V DC
Input voltage range "1" signal 11 V DC ... 30 V DC
Nominal input voltage UIN 24 V DC
Nominal input current at UIN 3 mA
Protective circuit Transient protection; Suppressor diode
Encoder
Number of inputs 1 (A, B, Z)
Input name Incremental encoder input
Encoder signals Asymmetrical encoder
Cable length < 30 m (Shielded cable)

Type modular
Product type I/O component
Mounting position See the system in which the Smart Element is used.
Insulation characteristics
Overvoltage category II (IEC 60664-1)
Pollution degree 2 (EN 60664-1)

Encoder
5 V encoder supply
Number 1 (+5 V)
Nominal output voltage 5 V DC
Voltage range 5 V DC ... 5.5 V DC
Current carrying capacity max. 300 mA
Protective circuit Short-circuit protection; Electrical and thermal
Overload protection
Transient protection; Suppressor diode
Number 1 (+24 V)
Nominal output voltage 24 V DC
Voltage range 19.2 V DC ... 30 V DC
Current carrying capacity max. 500 mA
Protective circuit Short-circuit protection; Electrical (from approx. 600 mA)
Overload protection
Transient protection; Suppressor diode
Number 1 (A, B, Z)
Designation Asymmetrical incremental encoder
Input frequency max. 300 kHz
Potentials: Communications power supply of the Smart Elements (USE)
Supply voltage using card edge connectors
Current draw max. 40 mA
Potentials: I/O supply (UP)
Supply voltage 24 V DC (using card edge connectors)
Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current draw max. 700 mA
typ. 512 mA
Current consumption min. 11 mA (without connected peripherals)
Power consumption max. 21 W (of which 1.55 W internal losses)
Power consumption min. 264 mW
Protective circuit Surge protection; See the system in which the Smart Element is used.
Reverse polarity protection; Polarity protection diode

Connection technology
Connection name I/O
Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline Smart Elements” user manual.
Conductor connection
Connection method Push-in connection
Conductor cross section solid 0.25 mm² ... 1.5 mm²
Conductor cross section flexible 0.25 mm² ... 1.5 mm²
Conductor cross section AWG 24 ... 16
Conductor cross section flexible, with ferrule without plastic sleeve 0.25 mm² ... 1.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve 0.25 mm² ... 1.5 mm²
Stripping length 8 mm
I/O
Connection method Push-in connection
Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline Smart Elements” user manual.
Conductor cross section, rigid 0.25 mm² ... 1.5 mm²
Conductor cross section, flexible 0.25 mm² ... 1.5 mm²
Conductor cross section AWG 24 ... 16
Conductor cross section, flexible, with ferrule, with plastic sleeve 0.25 mm² ... 1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve 0.25 mm² ... 1.5 mm²
Stripping length 8 mm

Ambient temperature (operation) -25 °C ... 60 °C
Degree of protection IP20
Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Permissible humidity (operation) 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)

Protection class III (IEC 61140, EN 61140, VDE 0140-1)

Mounting type Smart Element slot
Mounting position See the system in which the Smart Element is used.

N.º de artigo 1182185
Pcs./Emb 1 Unidade
Quantidade mínima de pedido 1 Unidade
Chave comercial DRI
Chave de produto DRIB61
GTIN 4063151218379
Peso por unidade (inclusive embalagem) 38,44 g
Peso por unidade (excluindo embalagem) 35 g
Número do imposto alfandegário 85389091
País de origem DE


ECLASS

ECLASS-9.0 27242604
ECLASS-10.0.1 27242604
ECLASS-11.0 27242604

ETIM

ETIM 8.0 EC001599

UNSPSC

UNSPSC 21.0

UL Listed

Approval ID: FILE E 238705

cUL Listed

Approval ID: FILE E 238705

cULus Listed


REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads”

Produtos compatíveis




Vantagens

Acquisition of digital signals from asymmetrical incremental encoders (A, B, Z)
Acquisition of pulses of up to 300 kHz
Evaluating linear or rotary axes
Power supply for 5 V or 24 V encoder
1 input can be used for referencing
Latch function for quick buffering of positions
32-bit register to output the measured increments
Device rating plate stored