UL Recognized
ID de certificação: FILE E 118976Tensão nominal UN | Corrente nominal IN | Secção transversal American Wire Gauge | Secção transversal mm2 | |
---|---|---|---|---|
Power | 600 V | 16 A | - 14 | |
Control | 600 V | 10 A | - 14 |
Contact insert, number of positions: 8+24+PE, size: B10, power contacts: 8, control contacts: 24, Pin, Crimp connection, 230 V, 16 A, 0.5 mm2 ... 4 mm2, application: Power/signal
General | For housing HC-B10, power contacts: CK 2,5-ED, control contacts: CK 1,6-ED (crimp contacts not included in scope of delivery) |
General | Connectors may be operated only when there is no load/voltage. |
Assembly note | To ensure correct use, installation in housing with IP54 protection or better is required |
Product type | Contact insert with a fixed no. of positions |
Series | HC-K |
Application | Power/signal |
Type | B10 |
Number of positions | 32 |
Connection profile | 8+24+PE |
Contact numbering | 1 - 8 (power contacts) |
1 - 24 (control contacts) | |
No. of power contacts | 8 |
No. of control contacts | 24 |
Contact material type | turned |
Insulation characteristics | |
Overvoltage category | III |
Degree of pollution | 3 |
Dimensional drawing |
|
Width | 34 mm |
Height | 36 mm |
Length | 64 mm |
Drill hole distance, horizontal | 57 mm |
Mechanical characteristics | |
Contact diameter | 2.5 mm |
Connection technology | |
Connection technology | Crimp connection (power contacts) |
Crimp connection (Signal contacts) | |
Conductor connection | |
Conductor cross section | 0.5 mm² ... 4 mm² (power contacts) |
0.14 mm² ... 2.5 mm² (control contacts) | |
Connection cross section AWG | 20 ... 12 (power contacts) |
26 ... 14 (control contacts) | |
Tightening torque | 0.8 Nm ... 1.2 Nm (PE connection) |
0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing) | |
Stripping length of the individual wire | 7.5 mm (Power) |
8 mm (Signal 0.14 mm² ... 1.5 mm²) | |
6 mm (Signal 2.5 mm²) |
Rated voltage (III/3) | 230 V (Power contacts wire-ground) |
160 V | |
400 V (Power contacts wire-wire) | |
Rated voltage for power contacts | 230/400 V |
Rated surge voltage | 4 kV (power contacts) |
2.5 kV (control contacts) | |
Rated current | 16 A (power contacts) |
10 A (control contacts) |
Mechanical data | |
Insertion/withdrawal cycles | ≥ 500 |
Flammability rating according to UL 94 | V0 |
Contact material | Cu alloy |
Contact carrier material | PC |
Material of contact surface, power contact | Ag (alternat. Au) |
Material of contact surface, control contact | Ag (alternatively Au) |
Standards/regulations | PC |
PC |
Ambient conditions | |
Ambient temperature (operation) (Operation) | -40 °C ... 125 °C (including heating up of contacts) |
Testing | |
Standards/regulations | PC: Fire protection in rail vehicles - requirement set R22 acc. to DIN EN 45545-2 (Risk level HL1 - HL2) |
PC: Fire protection in rail vehicles - requirement set R23 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
N.º de artigo | 1636318 |
Pcs./Emb | 1 Unidade |
Quantidade mínima de pedido | 1 Unidade |
Chave comercial | AF7 |
Chave de produto | AF7ABA |
GTIN | 4046356011457 |
Peso por unidade (inclusive embalagem) | 54,1 g |
Peso por unidade (excluindo embalagem) | 52,7 g |
Número do imposto alfandegário | 85366990 |
País de origem | CN |
ECLASS-13.0 | 27440205 |
ETIM 9.0 | EC000438 |
UNSPSC 21.0 | 39121500 |
Tensão nominal UN | Corrente nominal IN | Secção transversal American Wire Gauge | Secção transversal mm2 | |
---|---|---|---|---|
Power | 600 V | 16 A | - 14 | |
Control | 600 V | 10 A | - 14 |
EU RoHS | |
Cumpre os requisitos de substância segundo a Diretiva RoHS | Sim (Sem regras de exceção) |
China RoHS | |
Environment friendly use period (EFUP) |
EFUP-E
Nenhuma substância perigosa acima dos valores-limite
|
EU REACH SVHC | |
Nota sobre as substâncias candidatas ao REACH (n.º CAS) | Nenhuma substância numa proporção superior a 0,1 % em massa |