PLC-PT-TR/INV
-
Switching amplifier
1395232
The inverter module with Push-in connection inverts the signals of ground switching NPN transistor outputs into positive switching PNP outputs, as well as signals from PNP into NPN switching signals.
Detalhes dos produtos
Notes on operation | The PLC-ATP separating plate should be installed for safe isolation between adjacent modules |
Notes on operation | At least one functional insulation against adjacent modules is complied with in the support rail direction. If the application has higher requirements on the insulation (basic or reinforced insulation), then these must be realized through suitable measures (e. g., partition plates). |
Notes on operation | This item is intended to be used exclusively as a supplied part for further processing by industry, trade, or other companies with expertise in the field of EMC. |
Product type | Solid-state relay module |
Product family | PLC-INTERFACE |
Operating mode | 100% operating factor |
Insulation characteristics | |
Overvoltage category | II |
Pollution degree | 2 |
Rated insulation voltage | 50 V DC |
Rated surge voltage | 0.5 kV |
Supply | |
Supply voltage UVcc | 24 V DC |
Supply voltage range | 20 V DC ... 30 V DC |
Typical input current at UN | 6 mA |
Protective circuit | Surge protection |
Surge voltage protection | > 33 V |
Transmission frequency | 15 kHz |
NPN | |
Switching threshold "1" signal voltage | ≤ 5 V (at UVcc) |
Switching threshold "0" signal, voltage | ≥ 15 V (at UVcc) |
Min. voltage input signal | -2 V |
Max. voltage input signal | 26 V |
PNP | |
Switching threshold "1" signal voltage | ≥ 19 V |
Switching threshold "0" signal, voltage | ≤ 9 V |
Min. voltage input signal | -2 V |
Max. voltage input signal | 26 V |
Continuous load current | 200 mA (OUT1/OUT2) |
Leakage current | < 1 mA |
Residual voltage | < 1 V |
Transmission frequency | 15 kHz |
Surge voltage protection | > 33 V |
Protective circuit | Surge protection |
Connection method | Push-in connection |
Stripping length | 8 mm |
Conductor cross section rigid | 0.14 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible (2 conductors with same cross section) | 0.5 mm² ... 1 mm² (TWIN ferrule with plastic sleeve) |
Conductor cross section AWG | 26 ... 14 |
Width | 6.2 mm |
Height | 80 mm |
Depth | 94 mm |
Ambient conditions | |
Degree of protection | IP20 (Device) |
Degree of protection (Installation location) | IP54 (Installation location) |
Ambient temperature (operation) | -25 °C ... 60 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Altitude | ≤ 2000 m |
Standards/regulations | DIN EN 60664-1 |
Mounting type | DIN rail mounting |
Assembly note | in rows with zero spacing |
Mounting position | any |
N.º de artigo | 1395232 |
Pcs./Emb | 10 Unidade |
Quantidade mínima de pedido | 1 Unidade |
Chave comercial | DK6 |
Chave de produto | DK6223 |
GTIN | 4063151776879 |
Peso por unidade (inclusive embalagem) | 29,15 g |
Peso por unidade (excluindo embalagem) | 26,95 g |
Número do imposto alfandegário | 85365019 |
País de origem | DE |
ECLASS
ECLASS-13.0 | 27371604 |
ETIM
ETIM 9.0 | EC001504 |
EU RoHS | |
Cumpre os requisitos de substância segundo a Diretiva RoHS | Sim |
isenções tanto quanto conhecido | 7(a), 7(c)-I |
China RoHS | |
Environment friendly use period (EFUP) |
EFUP-50
Uma lista de declaração de acordo com a RoHS da China relativa a artigos encontra-se na área de transferências do respetivo artigo, em "Declaração do fabricante". Para todos os artigos com EFUP-E não é emitida nem necessária uma tabela de declaração de acordo com a RoHS da China.
|
EU REACH SVHC | |
Nota sobre as substâncias candidatas ao REACH (n.º CAS) | Lead (n.º CAS: 7439-92-1) |
SCIP | bf2786a3-da31-44ce-9c65-0dfa90e0d324 |
Phoenix Contact S.A.
Sintra Business Park, Edifício n°1 Zona Industrial da Abrunheira, sala 0M, 2710-089 SINTRA