ANT-DIR-868-01
-
Antenna
2702137
Directional antenna for mast or panel mounting, frequency band: 868 MHz, gain: 3.5 dBi, circular polarized, degree of protection: IP67, shockproof: IK06, seawater-resistant, connection: N (female), incl. mounting bracket and mast clamps, ATEX and IECEx approval
Detalhes dos produtos
| Note on application | |
| Note on application | Only for industrial use |
| Utilization restriction | |
| CCCex note | Use in potentially explosive areas is not permitted in China. |
| Scope of supply | included mounting bracket and mast clamps |
| Radiation characteristics | Directional |
| Gain | 3.5 dBi |
| Vertical beamwidth | 90 ° |
| Horizontal beamwidth | 135 ° |
| Polarization | Circular clockwise |
| Frequency band | 868 MHz |
| Frequency range | 865 MHz ... 870 MHz |
| Impedance | 50 Ω |
| Maximum capacity | 10.00 W |
| Voltage standing wave ratio VSWR in a 50 Ω system | ≤ 2.00 |
| Connection technology | |
| Connection method | N (female) |
| Outside diameter | 25 mm ... 85 mm (Mast) |
| Safety data | |
| Input voltage Ui | max. 30 V |
| Input current Ii | max. 600 mA |
| Input power Pi | 0.89 W (Maximum HF input power, 29.5 dBm, group IIC) |
| 1.54 W (Maximum HF input power, 31.9 dBm, group IIB) | |
| 2.63 W (Maximum HF input power, 34.2 dBm, group IIA) | |
| Max. internal inductance Li | negligible |
| Max. internal capacitance Ci | negligible |
| Dimensional drawing |
|
| Width | 80 mm |
| Height | 100 mm |
| Length | 35 mm |
| External dimensions | |
| Outside diameter | 25 mm ... 85 mm (Mast) |
| Material (Radom) | PC |
| Material (Holder) | Stainless steel V2A |
| Material (Mast clamp) | Stainless steel V2A |
| Flammability rating according to UL 94 | V0 |
| Other resistance | salt water resistant |
| Ambient conditions | |
| Degree of protection | IP67 |
| Impact strength | IK06 |
| Ambient temperature (operation) | -40 °C ... 75 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Air pressure (operation) | 80 kPa ... 110 kPa |
| Wind velocity | 220 km/h |
| CE | |
| Certificate | CE-compliant |
| ATEX | |
| Identification | II 1G Ex ia IIC T6 Ga |
| Certificate | IBExU14ATEX1116 X |
| Note | Please follow the special installation instructions in the documentation! |
| IECEx | |
| Identification | Ex ia IIC T6 Ga |
| Certificate | IECEx IBE 14.0039X |
| Electronic devices in rail vehicles | |
| Shock (operation) | In accordance with EN 50125-3, positioning profile: “away from the rails” |
| Vibration (operation) | In accordance with EN 50125-3, positioning profile: “away from the rails” |
| Other resistance | salt water resistant |
| Standards/specifications | EN 60079-0 |
| EN 60079-11 | |
| EN 60079-26 | |
| Note | Explosion protection |
| Standards/specifications | EN 50155 |
| Note | Railway application |
| Standards/specifications | EN 45545-2 |
| NFPA 130 | |
| BS 6853 | |
| Note | Fire protection on railway vehicles |
| Mounting type | Panel mounting |
| Mast mounting | |
| Assembly note | Outdoors and indoors |
| N.º de artigo | 2702137 |
| Pcs./Emb | 1 Unidade |
| Quantidade mínima de pedido | 1 Unidade |
| Chave comercial | DNC |
| Chave de produto | DNC6A2 |
| GTIN | 4055626006512 |
| Peso por unidade (inclusive embalagem) | 519,2 g |
| Peso por unidade (excluindo embalagem) | 519,2 g |
| Número do imposto alfandegário | 85177100 |
| País de origem | PL |
ECLASS
| ECLASS-13.0 | 19070105 |
| ECLASS-15.0 | 19070105 |
ETIM
| ETIM 9.0 | EC001698 |
UNSPSC
| UNSPSC 21.0 | 43223100 |
| EU RoHS | |
| Cumpre os requisitos de substância segundo a Diretiva RoHS | Sim |
| isenções tanto quanto conhecido | 6(c) |
| China RoHS | |
| Environment friendly use period (EFUP) |
EFUP-25
Uma lista de declaração de acordo com a RoHS da China relativa a artigos encontra-se na área de transferências do respetivo artigo, em "Declaração do fabricante". Para todos os artigos com EFUP-E não é emitida nem necessária uma tabela de declaração de acordo com a RoHS da China.
|
| EU REACH SVHC | |
| Nota sobre as substâncias candidatas ao REACH (n.º CAS) | Lead (n.º CAS: 7439-92-1) |
| SCIP | 93e5b86f-e1d4-44c9-a447-32f8cfaa62e1 |
Produtos compatíveis
-
-
RAD-PIG-RSMA/N-1 - Antenna cable 2903264
-
RAD-PIG-RSMA/N-2 - Antenna cable 2903265
-
RAD-PIG-RSMA/N-3 - Antenna cable 2903266
-
RAD-PIG-RSMA/N-5 - Antenna cable 2702140
-
CN-UB-70DC-6-BB - Surge protection device 2803166
-
RAD-ADP-N/F-N/F - Adapter 2867843
-
BAR-ANT-N-N-EX - Antenna barrier 2702198
-
NBC-COX-CNM/0.5-M/COX-CNM - Coaxial cable 1340122
-
NBC-COX-CNM/3.0-L/COX-CNM - Coaxial cable 1340123
-
NBC-COX-CNM/5.0-L/COX-CNM - Coaxial cable 1340124
-
NBC-COX-CNM/10.0-L/COX-CNM - Coaxial cable 1340125
-
NBC-COX-CNM/15.0-L/COX-CNM - Coaxial cable 1340126
-
NBC-COX-CNM/30.0-L/COX-CNM - Coaxial cable 1340127
-
RAD-ADP-RSMA/M-RSMA/F-90 - Adapter 2904790
-
RAD-SPL-2-N/N - Antenna splitter 2702293
-
RAD-TAPE-SV-19-3 - Weather protection tape 2903182
Vantagens
Ideally suited for stationary or linear mobile 868 MHz applications
For applications in reflective environments
For use in potentially explosive areas
Resistant to salt water
Pesquisado com frequência
Phoenix Contact S.A.
Sintra Business Park, Edifício n°1 Zona Industrial da Abrunheira, sala 0M, 2710-089 SINTRA