APP-LIC-WATER-FUNCTIONS-VISU - Licença
1270956

Licença para a utilização da biblioteca Water Functions Visu. Water Functions Visu oferece, adicionalmente à biblioteca de blocos de funções Water Functions, a funcionalidade remota e objetos de visualização para a indústria de água e de águas residuais.

Download gratuito disponível. Downloads

Detalhes do produto








Produtos compatíveis



Perguntas frequentes


Existe um tutorial de hardware que explique as funções do CAPAROC?

video thumbnail of faq answer

Sim, há um tutorial de hardware para ajudá-lo a começar a usar o CAPAROC.... Ver mais

Sim, há um tutorial de hardware para ajudá-lo a começar a usar o CAPAROC.

Ver menos

How many circuit breaker modules can I connect downstream of an infeed module?

CAPAROC PM S-R: 20 circuit breaker modules
CAPAROC PM IOL: 20 channels
CAPAROC PM PN: 16 circuit breaker modules
CAPAROC PM EIP: 16 circuit breaker modules
CAPAROC PM MB: 16 circuit breaker modules
CAPAROC PM EC: 16 circuit breaker modules


The channel LED flashes yellow twice every 4 seconds. What does this mean?

This means that the internal communication to the power module is interrupted or faulty.
Check that the modules are mounted correctly and that there is no gap between the modules. If communication is still disrupted, check the side contacts of the... Ver mais

This means that the internal communication to the power module is interrupted or faulty.
Check that the modules are mounted correctly and that there is no gap between the modules. If communication is still disrupted, check the side contacts of the first module (left) that is flashing, if they are bent, either too far into the module, not centered in the housing opening or otherwise damaged, replace the module.

Ver menos

Can I block the setting of the set currents?

The currents can be locked in different ways:
1. Programming lock: press the PWR button on the power module for > 3 seconds, the PWR LED flashes yellow 3 x, the settings are now locked. Pressing it again for > 3 seconds causes the LED to fla... Ver mais

The currents can be locked in different ways:
1. Programming lock: press the PWR button on the power module for > 3 seconds, the PWR LED flashes yellow 3 x, the settings are now locked. Pressing it again for > 3 seconds causes the LED to flash green 3 times and unlocks it again.
2. The lock can also be set and released via the communication interface; the operating lock can also be set here, which prevents operation and settings on the device. The lock can then only be released via the interface.

Ver menos