FL SWITCH 2208 - Industrial Ethernet Switch
2702327

Managed Switch 2000, 8 RJ45 ports 10/100 Mbps, PROFINET Conformance-Class B, Extended temperature range

Free Download available. Downloads

Product Details




Dimensional drawing
Width 45 mm
Height 130 mm
Depth 119 mm

General Support by phone or on-site (fee is charged)
Utilization restriction
EMC note EMC: class A product, see manufacturer's declaration in the download area

Housing material Polycarbonate fiber reinforced

Mounting type DIN rail mounting

Ethernet (RJ45)
Connection method RJ45
Note on the connection method Auto negotiation and autocrossing
Transmission speed 10/100 Mbps
Transmission physics Copper
Transmission length 100 m (per segment)
Signal LEDs Data receive, link status
No. of channels 8 (RJ45 ports)

Digital
Output name Alarm output

Type Book type
Product type Switch
Product family Managed Switch 2000
MTTF 494.02 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
235.18 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
29.73 Years (SN 29500 standard, temperature 70°C, operating cycle 100%)
Special properties Extended temperature range
Signal delay ≥ 6.5 µs (Store and Forward mode, 10/100 Mbps, depending on the frame size)
Insulation characteristics
Protection class III (VDE 0106)
Degree of pollution 2
Switch functions
Diagnostic functions RMON History
LLDP (Link Layer Discovery Protocol)
SNMP-Traps
N:1-Portmirroring
ACD (Address Conflict Detection)
SysLog
CRC-Surveillance
Basic functions Store-and-forward switch, complies with IEEE 802.3
Signal contact control voltage typ. 24 V DC
PROFINET conformance class Conformance-Class B
PROFINET device function PROFINET device
Fast Startup
Filter functions Quality of Service (8 priority classes)
Class of Service
DiffServ/DSCP
Port-Priorisierung
VLAN (up to 32 VLANs)
IGMP Snooping/Querier (v1/v2)
Auto-Query-Port
Extended Multicast Filtering
IP parameterization DHCP-Client
DHCP Option 82 (Relay Agent)
DHCP server (pool-based, port-based)
BootP
DCP (Discovery and Configuration Protocol)
MAC address table 8k
Management Web-based management (HTTP/HTTPS)
Role-based user management (LDAP, RADIUS)
SNMPv1/v2/v3
Command-line interface (Telnet, SSH)
Redundancy MRP (Media Redundancy Protocol)
RSTP (Rapid Spanning Tree Protocol)
FRD (Fast Ring Detection)
Large Tree Support
LACP (Link Aggregation Control Protocol)
PROFINET S2 system redundancy
Status and diagnostic indicators LEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (Link/Activity and Speed)
Additional functions Transmission of MMS and GOOSE (IEC 61850-8-1)
Transmission of Modbus/TCP
Time synchronization SNTP (Simple Network Time Protocol)
Security functions
Port security MAC-based, RADIUS (IEEE 802.1X), MAC Authentication Bypass
Basic functions Store-and-forward switch, complies with IEEE 802.3

Local diagnostics US1/2 Supply voltage US1, US2 Green LED
FAIL Div. LED red
LINK Link status Green LED
Maximum power dissipation for nominal condition 4.95 W (US = Min, Tamb = Max, DOI = Max)
Test voltage 500 V DC
Test section for one minute 500 V DC
Transmission medium Copper
Supply
Supply voltage (DC) 24 V DC (redundant)
Supply voltage range 12 V DC ... 57 V DC
Power supply connection via COMBICON, max. conductor cross section 1.5 mm²
Residual ripple 3.6 VPP (within the permitted voltage range)
Max. current consumption 1.3 A (US = Min, Tamb = Max, DOI = Max)
Typical current consumption 185 mA (at US = 24 V DC and 25 °C ambient temperature)
Current consumption 190 mA
Function
Signal contact control voltage typ. 24 V DC

Connection method Push-in spring connection
Note on the connection method Use only copper connecting cables providing the permitted temperature range (-40 °C ... 75 °C).
Conductor cross section, rigid 0.25 mm² ... 1.5 mm²
Conductor cross section, flexible 0.25 mm² ... 1.5 mm²
Conductor cross section AWG 24 ... 16
Stripping length 9 mm

Ambient conditions
Degree of protection IP20
Ambient temperature (operation) -40 °C ... 70 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Permissible humidity (operation) 10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing)
Shock (operation) 30g (EN 60068-2-27)
Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz
Air pressure (operation) 80 kPa ... 110 kPa up to 2000 m above mean sea level (Without derating)
Air pressure (storage/transport) 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating)

Free from substances that could impair the application of coating Yes

Shipbuilding approval Tested in accordance with IEC 60945 and IACS E10
ATEX
Identification  II 3 G Ex ec IIC T4 Gc
Certificate DEMKO 16 ATEX 1709X
IECEx
Identification Ex ec IIC T4 Gc
Certificate IECEx ULD 16.0018 X
UL, USA / Canada
Identification cULus
UL Ex, USA / Canada
Identification Class I, Division 2, Groups A, B, C, and D, T4
Class I, Zone 2, AEx ec IIC T4
Ex ec IIC T4 Gc X
Certificate E366272
Note UL 60079-0 Ed. 6 / UL 60079-7 Ed. 5, CSA 22.2 No. 60079-0 Ed. 3 / CSA C22.2 No. 60079-7 Ed. 2
EAC Ex
Identification 2Ex e IIC T4 Gc X
Certificate RU C-DE.HB49.B.00118/21
The following continue to apply for EAC Ex:
Identification При монтаже использовать походящий допущенный корпус со степенью защиты не ниже IP66.
На корпусе/шкафу управления должна быть размещена предупреждающаяя надпись, запрещающая открывать корпус или шкаф во взрывоопасной зоне.
Эксплуатация устройства допускается только при условии, что все оптические порты заняты подключенными устройствами или закрыты прилагаемыми заглушками.
CCC / China-Ex
Identification Ex ec IIC T4 Gc
Certificate 2022122310115629
Corrosive gas test
Identification ISA S71.04.2013 G3 Harsh Group A
UKCA Ex (UKEX)
Identification  II 3 G Ex ec IIC T4 Gc
Certificate PxCIMA22UKEX2702910X
DNV GL data
Temperature B
Humidity B
Vibration A
EMC B
Enclosure Required protection according to the Rules shall be provided upon installation on board

Conformance with EMC directives EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B
EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion A
EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A
EN 61000-6-2 EN 61000-4-5 (surge) Criterion B
EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A
EN 61000-6-2 EN 61000-6-4 (interference) Class A
EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Noise emission EN 61000-6-4
Noise immunity EN 61000-6-2

Status display LEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (Link/Activity and Speed)

Item number 2702327
Packing unit 1 pc
Minimum order quantity 1 pc
Product Key DNN121
Catalog Page Page 306 (C-6-2019)
GTIN 4055626128931
Weight per Piece (including packing) 396.1 g
Weight per Piece (excluding packing) 230 g
Customs tariff number 85176200
Country of origin DE


ECLASS

ECLASS-9.0 19170106
ECLASS-10.0.1 19170401
ECLASS-11.0 19170401

ETIM

ETIM 8.0 EC000734

UNSPSC

UNSPSC 21.0 43222600

EAC

Approval ID: RU*-DE.*.B.00741/19

DNV GL

Approval ID: TAA00000YV

LR

Approval ID: LR22250919TA

NK

Approval ID: TA19464M

BV

Approval ID: 48146/A1 BV

UL Listed

Approval ID: FILE E 238705

cUL Listed

Approval ID: FILE E 238705

BSH

Approval ID: Nr. 966

RINA

Approval ID: ELE162721XG

ABS

Approval ID: 21-2066186-PDA

cUL Listed

Approval ID: FILE E 366272

UL Listed

Approval ID: FILE E 366272

IECEx

Approval ID: IECEx ULD 16.0018X

ATEX

Approval ID: DEMKO 16 ATEX 1709X

cULus Listed

cULus Listed


REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads”

Your advantages

DHCP client, DHCP server (pool-based and port-based), DHCP option 82
Ambient temperature -40 °C ... 70 °C
VLANs
MRP (client and manager)
RSTP
Web-based management, SNMP
Configuration memory
Slim design
Easy and fast startup and commissioning with the FL NETWORK MANAGER software
Suitable for PROFINET and EtherNet/IP™ networks