The midspan injectors connect Ethernet devices without PoE (e.g., switches) to PoE-capable end devices (e.g., IP cameras). As power sourcing equipment (PSE), the injector supplies the required power to a powered device (PD) via the data cable. The injector and end device negotiate the electrical power requirements autonomously.
INJ 1100-T
-
Injector
2703009
PoE injector, 30 W, two RJ45 jacks, 10/100/1000 Mbps, DIN rail mounting, IP20, expanded temperature range of -40°C ... 75°C, potential separation
Product details
Dimensional drawing |
|
Width | 30.2 mm |
Height | 130 mm |
Depth | 120 mm |
Note on application | |
Note on application | Only for industrial use |
Utilization restriction | |
CCCex note | Use in potentially explosive areas is not permitted in China. |
Color (Housing) | light gray (RAL 7035) |
Material (Housing) | Plastic |
Flammability rating according to UL 94 | V0 |
Mounting type | DIN rail mounting |
Mounting position | vertical |
Basic functions | PSE/Midspan, compliant with IEEE 802.3af, at |
Data: Power over Ethernet | |
Serial transmission speed | 10/100/1000 Mbps |
Frequency range | 125 MHz |
Connection method | RJ45 jack |
Note on the connection method | CAT5e |
No. of channels | 1 |
Pin assignment | 1:1 |
Transmission length | 100 m (including patch cables) |
Output nominal voltage | 54 V DC (PoE) |
Output power | 30 W |
Maximum output power | 40 W (UL) |
Data: Ethernet | |
Connection method | RJ45 jack |
Note on the connection method | CAT5e |
Product type | Injector |
MTTF | 2342 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
1167 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) | |
467 Years (SN 29500 standard, temperature 40°C, operating cycle 100%) |
Electrical isolation | VCC // FE // PoE |
Maximum power dissipation for nominal condition | 7 W (at 18 V DC) |
5 W (24 V DC ... 48 V DC) | |
Test voltage data interface/power supply | 500 V (50 Hz, 1 min.) |
Supply | |
Supply voltage range | 18 V DC ... 57 V DC |
Nominal supply voltage | 24 V DC (SELV/PELV, restrictions for ATEX applications) |
48 V DC | |
Max. current consumption | 2.1 A |
1.4 A (24 V DC, Ex areas in accordance with UL-HazLoc) | |
0.7 A (48 V DC, Ex areas in accordance with UL-HazLoc) | |
Power consumption | ≤ 40 W |
Protective circuit | Reverse polarity protection |
Function | |
Current | ≤ 2 A |
Supply | |
Connection method | Push-in connection |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 2.5 mm² |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 2.5 mm² |
Single conductor/terminal point, rigid | 0.2 mm² ... 2.5 mm² |
Single-wire/terminal point, flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section, flexible [AWG] | 20 ... 12 |
Stripping length | 10.00 mm |
Ambient conditions | |
Degree of protection | IP20 (Manufacturer's declaration) |
Ambient temperature (operation) | -40 °C ... 65 °C (75°C, observe derating) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Altitude | ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation) |
≤ 2000 m (Restrictions for ATEX applications) | |
Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
Air pressure (operation) | 80 kPa ... 110 kPa (Restrictions for ATEX applications) |
CE | |
Certificate | CE-compliant |
ATEX | |
Identification | II 3G Ex ec nC IIC T4 Gc |
Certificate | PxCIF19ATEX2703009X |
Note | Please follow the special installation instructions in the documentation! |
UL, USA/Canada | |
Identification | Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4 |
Class I, Div. 2, Groups A, B, C, D | |
UL, USA | |
Certificate | UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4 |
UL, Canada | |
Certificate | CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16 |
Corrosive gas test | |
Identification | ISA-S71.04-1985 G3 Harsh Group A |
Power over Ethernet | |
Identification | IEEE 802.3af |
IEEE 802.3at |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
FCC Part 15B Class A | |
CISPR 22 | |
Electrostatic discharge | |
Standards/regulations | EN 61000-4-2 |
Electrostatic discharge | |
Contact discharge | ± 6 kV (Test Level 3) |
Discharge in air | ± 8 kV (Test Level 3) |
Indirect discharge | ± 6 kV |
Comments | Criterion B |
Electromagnetic HF field | |
Standards/regulations | EN 61000-4-3 |
Electromagnetic HF field | |
Frequency range | 80 MHz ... 3 GHz (Test Level 3) |
Field intensity | 10 V/m |
Comments | Criterion A |
Fast transients (burst) | |
Standards/regulations | EN 61000-4-4 |
Fast transients (burst) | |
Input | ± 2.2 kV (1 minute) |
Signal | ± 2.2 kV (1 minute) |
Comments | Criterion B |
Surge current load (surge) | |
Standards/regulations | EN 61000-4-5 |
Surge current load (surge) | |
Input | ± 0.5 kV |
Signal | ± 1 kV (Data line, asymmetrical) |
± 2 kV (I/O cable on field side only, asymmetric) | |
Comments | Criterion B |
Conducted interference | |
Standards/regulations | EN 61000-4-6 |
Conducted interference | |
Frequency range | 0.15 MHz ... 80 MHz |
Comments | Criterion A |
Voltage | 10 V |
Emitted interference | |
Standards/regulations | EN 61000-6-4 |
Comments | Class A, industrial applications |
Emitted interference | |
Standards/regulations | EN 61000-6-3 |
Comments | Class B, domain of use: residential and small commercial |
Criteria | |
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Functionality | |
Basic functions | PSE/Midspan, compliant with IEEE 802.3af, at |
Item number | 2703009 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Product key | DNC351 |
Catalog page | Page 345 (C-6-2019) |
GTIN | 4055626462974 |
Weight per piece (including packing) | 432.4 g |
Weight per piece (excluding packing) | 338.18 g |
Customs tariff number | 85044083 |
Country of origin | DE |
ECLASS
ECLASS-13.0 | 19170112 |
ETIM
ETIM 9.0 | EC001128 |
UNSPSC
UNSPSC 21.0 | 43223300 |
EU RoHS | |
Fulfills EU RoHS substance requirements | Yes |
Exemption | 6(c), 7(a), 7(c)-I |
China RoHS | |
Environment friendly use period (EFUP) |
EFUP-50
An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required.
|
EU REACH SVHC | |
REACH candidate substance (CAS No.) | Lead (CAS: 7439-92-1) |
SCIP | 13ffeeb7-1634-4db8-acfb-4ec14abf0c82 |
Compatible products
-
FL CRIMPTOOL - Assembly tool 2744869
-
FL ISOLATOR 100-RJ/RJ - Network isolator 2313931
-
FL ISOLATOR 1000-RJ/RJ - Network isolator 2313915
-
FL ISOLATOR 100-M12 - Network isolator 2902985
-
NBC-R4AC-R4AC-IE8A/.../... - Patch cable 1411854
-
NBC-R4AC/10G-R4AC/10G-94F/2,0 - Patch cable 1408360
-
NBC-R4AC/10G-R4AC/10G-94F/3,0 - Patch cable 1408365
-
NBC-R4ACS/1,0-93B/R4ACS - Patch cable 1112817
-
NBC-R4ACS/2,0-93B/R4ACS - Patch cable 1112820
-
FL CAT5 PATCH 0,3 - Patch cable 2832250
-
FL CAT5 PATCH 0,5 - Patch cable 2832263
-
FL CAT5 PATCH 1,0 - Patch cable 2832276
-
FL CAT5 PATCH 1,5 - Patch cable 2832221
-
FL CAT5 PATCH 2,0 - Patch cable 2832289
-
FL CAT5 PATCH 3,0 - Patch cable 2832292
-
VS-08-RJ45-10G/Q - RJ45 connector 1419001
-
VS-PN-RJ45-5-Q/IP20 - RJ45 connector 1658435
-
VS-08-RJ45-5-Q/IP20 - RJ45 connector 1656725
-
VS-08-RJ45-5-Q/IP20 BK - RJ45 connector 1658008
-
VS-CABLE-STRIP-VARIO - Stripping tool 1657407
-
SZF 0-0,4X2,5 - Screwdriver 1204504
-
MICROFOX-SP - Diagonal cutter 1212488
-
VS-OE-OE-94F/... - Data cable 1417359
-
FL DIN RA - DIN rail adapter 2891053
Your advantages
Extended temperature range of -40 °C ... +75 °C
Extended supply voltage range of 18 V DC ... 57 V DC, redundant
Electrical isolation of the internal power supply unit for protection against short circuits on the PoE side
10/100/1000 Mbps
Frequently searched
Phoenix Contact GmbH & Co. KG
Flachsmarktstraße 8, D-32825 Blomberg