The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration.
Notes on operation
FE not connected to metal parts that can be touched, no protective function
Order information:
Lock nut is included in the scope of delivery
Mounting type
Rear mounting (M16 x 1.5, XL version, with flat nut, tightening limitation)
Product type
Circular connectors (device side)
Application
Power
Sensor type
Power
Number of positions
5
Connection profile
4+FE
No. of cable outlets
1
Shielded
no
Coding
L
Thread type
M12
Insulation characteristics
Overvoltage category
III
Degree of pollution
3
Material Housing
GD-Zn
Material Housing surface
Ni
Material Molding compound
PUR (potted)
Flammability rating according to UL 94
V0
Seal material
FKM
Contact material
CuZn
Contact surface material
Au
Contact carrier material
PA
Conductor material
Tin-plated Cu litz wires
Rated voltage in acc. with IEC 61076-2-101
63 V
Rated surge voltage
1.5 kV
Rated surge voltage
1.5 kV AC/DC
Nominal voltage UN
63 V DC
Nominal current IN
16 A
Test voltage
1.5 kV
Test voltage Core/Core
6 kV
Conductor connection
Connection method
Individual wires
Contact connection type
Socket
Conductor cross-section
2.5 mm²
Mechanical data
Insertion/withdrawal cycles
> 100
Connection 1
Head design
Socket
Head cable outlet
straight
Head thread type
M12
Head locking type
Standard
Coding
L
Connection 2
Head design
free cable end
Cable length
0.2 m
Cable type
PEX litz wire
Signal type/category
Power
Single wire, color
brown 1, white 2, blue 3, black 4, pink FE
Cable cross section
2.5 mm²
Conductor material
Tin-plated Cu litz wires
AWG signal line
14
Material wire insulation
PE-X
Test voltage Core/Core
6 kV
Halogen-free
according to IEC 60754-1
Flame resistance
in acc. with UL FT-2
Other resistance
Hydrolysis-resistant
Ambient temperature (operation)
-40 °C ... 105 °C (cable, fixed installation)
-25 °C ... 105 °C (Cable, flexible installation)
Ambient conditions
Degree of protection
IP65
IP67
Ambient temperature (operation) (male connector/female connector)
-25 °C ... 85 °C (Plug / socket)
-40 °C ... 85 °C (without mechanical actuation)
Ambient temperature (operation) (Cable, flexible installation)
-25 °C ... 105 °C (Cable, flexible installation)
Ambient temperature (operation) (Cable, fixed installation)