Sensor/actuator terminal block - PTIO 1,5/S/4
3244452

Sensor/actuator terminal block, nom. voltage: 250 V, nominal current: 13.5 A, connection method: Push-in connection, Rated cross section: 1.5 mm2, cross section: 0.14 mm2 - 1.5 mm2, mounting type: NS 35/7,5, NS 35/15, color: gray


Product Details




Product type Sensor/actuator terminal block
Number of connections 5
Number of rows 4
Potentials 4
Insulation characteristics
Overvoltage category III
Degree of pollution 3

Rated surge voltage 4 kV
Maximum power dissipation for nominal condition 0.56 W

Service Entrance yes
Number of connections per level 2
Nominal cross section 1.5 mm²
Stripping length 8 mm ... 10 mm
Internal cylindrical gage A1 / B1
Connection in acc. with standard IEC 60947-7-1
Conductor cross section solid 0.14 mm² ... 1.5 mm²
Cross section AWG 26 ... 14
Conductor cross section flexible 0.14 mm² ... 1.5 mm²
Conductor cross section, flexible [AWG] 26 ... 14
Flexible conductor cross section flexible (ferrule, w/o plastic sleeve) 0.14 mm² ... 1.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve) 0.14 mm² ... 1 mm² Using the AI-S 1-8 TQ ferrule, Item No. 1200293, is recommended
Nominal current 13.5 A
Maximum load current 13.5 A
Nominal voltage 250 V
Nominal cross section 1.5 mm²
Connection cross sections directly pluggable
Conductor cross section solid 0.25 mm² ... 1.5 mm²
Flexible conductor cross section flexible (ferrule, w/o plastic sleeve) 0.34 mm² ... 1.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve) 0.34 mm² ... 1 mm²

Width 3.5 mm
End cover width 2.2 mm
Height 40 mm
Height NS 35/15 48.5 mm
Height NS 35/7,5 41.5 mm
Length 90.8 mm

Color gray
Flammability rating according to UL 94 V0
Insulating material group I
Insulating material PA
Static insulating material application in cold -60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
Relative insulation material temperature index (Elec., UL 746 B) 130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
Surface flammability NFPA 130 (ASTM E 162) passed
Specific optical density of smoke NFPA 130 (ASTM E 662) passed
Smoke gas toxicity NFPA 130 (SMP 800C) passed

Surge voltage test
Test voltage setpoint 4.8 kV
Result Test passed
Short-time withstand current 1.5 mm² 0.18 kA
Result Test passed
Power-frequency withstand voltage
Test voltage setpoint 1.5 kV
Result Test passed

Mechanical data
Open side panel Yes

Mechanical strength
Result Test passed
Attachment on the carrier
DIN rail/fixing support NS 35
Test force setpoint 1 N
Result Test passed
Test for conductor damage and slackening
Rotation speed 10 rpm
Revolutions 135
Conductor cross section/weight 0.14 mm² / 0.2 kg
1.5 mm² / 0.4 kg
Result Test passed

Aging
Temperature cycles 192
Result Test passed
Needle-flame test
Time of exposure 30 s
Result Test passed
Oscillation/broadband noise
Specification DIN EN 50155 (VDE 0115-200):2008-03
Spectrum Service life test category 2, bogie-mounted
Frequency f1 = 5 Hz to f2 = 250 Hz
ASD level 6.12 (m/s²)²/Hz
Acceleration 3.12g
Test duration per axis 5 h
Test directions X-, Y- and Z-axis
Result Test passed
Shocks
Specification DIN EN 50155 (VDE 0115-200):2008-03
Pulse shape Half-sine
Acceleration 30g
Shock duration 18 ms
Number of shocks per direction 3
Test directions X-, Y- and Z-axis (pos. and neg.)
Result Test passed
Ambient conditions
Ambient temperature (operation) -60 °C ... 105 °C (max. short-term operating temperature RTI Elec.)
Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient temperature (assembly) -5 °C ... 70 °C
Ambient temperature (actuation) -5 °C ... 70 °C
Permissible humidity (storage/transport) 30 % ... 70 %

Connection in acc. with standard IEC 60947-7-1

Mounting type NS 35/7,5
NS 35/15

Item number 3244452
Packing unit 1 pc
Minimum order quantity 50 pc
Sales Key B02
Product Key BE2218
Catalog Page Page 41 (C-1-2019)
GTIN 4046356735872
Weight per Piece (including packing) 8.239 g
Weight per Piece (excluding packing) 8.239 g
Customs tariff number 85369010
Country of origin PL


ECLASS

ECLASS-9.0 27141128
ECLASS-10.0.1 27141128
ECLASS-11.0 27141128

ETIM

ETIM 8.0 EC000900

UNSPSC

UNSPSC 21.0

CSA

Approval ID: 13631
Approval Specification Data
Nominal Voltage UN Nominal Current IN Cross Section AWG Cross Section mm2
Use group B
300 V 10 A 26 - 14
Use group C
150 V 15 A 26 - 14
Use group D
300 V 10 A 26 - 14

EAC

Approval ID: RU C-DE.BL08.B.00644

cULus Recognized

Approval ID: E60425
Approval Specification Data
Nominal Voltage UN Nominal Current IN Cross Section AWG Cross Section mm2
Use group B
300 V 15 A 26 - 14
Use group C
150 V 15 A 26 - 14
Use group D
300 V 10 A 26 - 14

China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Compatible Products


  1. Plug-in bridge FBS 2-3,5 - 3213014

    Max. current carrying capacity
    17.5 A
  2. Plug-in bridge FBS 3-3,5 - 3213027

    Max. current carrying capacity
    17.5 A
  3. Plug-in bridge FBS 4-3,5 - 3213030

    Max. current carrying capacity
    17.5 A
  4. Plug-in bridge FBS 5-3,5 - 3213043

    Max. current carrying capacity
    17.5 A
  5. Plug-in bridge FBS 10-3,5 - 3213056

    Max. current carrying capacity
    17.5 A
  6. Plug-in bridge FBS 20-3,5 - 3213069

    Max. current carrying capacity
    17.5 A
  7. Plug-in bridge FBS 50-3,5 - 3000706

    Max. current carrying capacity
    17.5 A
  8. Plug-in bridge FBS 2-3,5 BU - 3213086

    Max. current carrying capacity
    17.5 A
  9. Plug-in bridge FBS 3-3,5 BU - 3213099

    Max. current carrying capacity
    17.5 A
  10. Plug-in bridge FBS 4-3,5 BU - 3213109

    Max. current carrying capacity
    17.5 A
  11. Plug-in bridge FBS 5-3,5 BU - 3213112

    Max. current carrying capacity
    17.5 A
  12. Plug-in bridge FBS 10-3,5 BU - 3213125

    Max. current carrying capacity
    17.5 A
  13. Plug-in bridge FBS 20-3,5 BU - 3213138

    Max. current carrying capacity
    17.5 A
  14. Plug-in bridge FBS 50-3,5 BU - 3000708

    Max. current carrying capacity
    17.5 A
  15. Plug-in bridge FBS 2-3,5 GY - 3213153

    Max. current carrying capacity
    17.5 A
  16. Plug-in bridge FBS 3-3,5 GY - 3213167

    Max. current carrying capacity
    17.5 A
  17. Plug-in bridge FBS 4-3,5 GY - 3213180

    Max. current carrying capacity
    17.5 A
  18. Plug-in bridge FBS 5-3,5 GY - 3213183

    Max. current carrying capacity
    17.5 A
  19. Plug-in bridge FBS 10-3,5 GY - 3213196

    Max. current carrying capacity
    17.5 A
  20. Plug-in bridge FBS 20-3,5 GY - 3213206

    Max. current carrying capacity
    17.5 A
  21. Plug-in bridge FBS 50-3,5 GY - 3000707

    Max. current carrying capacity
    17.5 A
  22. End cover D-PTIO 1,5/S/4 - 3244588

  23. DIN rail perforated NS 35/ 7,5 PERF 2000MM - 0801733

  24. Mounting material PT-IL - 3208090

  25. DIN rail, unperforated NS 35/ 7,5 UNPERF 2000MM - 0801681

  26. Actuation tool ST-BW 0 - 1200135

  27. DIN rail perforated NS 35/ 7,5 WH PERF 2000MM - 1204119

  28. Marker for terminal blocks UCTU-TM (3,5X7) - 0803666

  29. DIN rail, unperforated NS 35/ 7,5 WH UNPERF 2000MM-VPE 10 - 1204122

  30. Cover segment DS-PTIO 1,5/S - 1045987

  31. DIN rail, unperforated NS 35/ 7,5 AL UNPERF 2000MM - 0801704

  32. Ferrule AI-S 1 - 8 TQ - 1200293

  33. DIN rail perforated NS 35/ 7,5 ZN PERF 2000MM - 1206421

  34. DIN rail, unperforated NS 35/ 7,5 ZN UNPERF 2000MM - 1206434

  35. DIN rail, unperforated NS 35/ 7,5 CU UNPERF 2000MM-VPE 10 - 0801762

  36. End cap NS 35/ 7,5 CAP - 1206560

  37. DIN rail perforated NS 35/15 PERF 2000MM - 1201730

  38. DIN rail, unperforated NS 35/15 UNPERF 2000MM - 1201714

  39. DIN rail perforated NS 35/15 WH PERF 2000MM - 0806602

  40. DIN rail, unperforated NS 35/15 WH UNPERF 2000MM-VPE 10 - 1204135

  41. DIN rail, unperforated NS 35/15 AL UNPERF 2000MM - 1201756

  42. DIN rail perforated NS 35/15 ZN PERF 2000MM - 1206599

  43. DIN rail, unperforated NS 35/15 ZN UNPERF 2000MM - 1206586

  44. DIN rail, unperforated NS 35/15 CU UNPERF 2000MM-VPE 10 - 1201895

  45. End cap NS 35/15 CAP - 1206573

  46. DIN rail, unperforated NS 35/15-2,3 UNPERF 2000MM-VPE 10 - 1201798

  47. Test plugs MPS-MT - 0201744

  48. Insulating sleeve MPS-IH WH - 0201663

  49. Insulating sleeve MPS-IH RD - 0201676

  50. Insulating sleeve MPS-IH BU - 0201689

  51. Insulating sleeve MPS-IH YE - 0201692

  52. Insulating sleeve MPS-IH GN - 0201702

  53. Insulating sleeve MPS-IH GY - 0201728

  54. Insulating sleeve MPS-IH BK - 0201731

  55. Software PROJECT COMPLETE - 1050453

  56. End clamp CLIPFIX 35 - 3022218

  57. End clamp CLIPFIX 35-5 - 3022276

  58. End clamp E/NS 35 N - 0800886

  59. Test plugs PS-3,5 - 3031010

  60. Spacer plate DP PS-3,5 - 3031011

  61. Test plugs PS-3,5/E - 3031012

  62. Zack Marker strip, flat ZBF 3,5:UNBEDRUCKT - 0829392

  63. Zack Marker strip, flat ZBF 3,5 CUS - 0829394

  64. Zack Marker strip, flat ZBF 3,5,LGS:FORTL.ZAHLEN - 0801406

  65. Zack Marker strip, flat ZBF 3,5,QR:FORTL.ZAHLEN - 0801407

  66. Marker for terminal blocks UCT-TMF 3,5 - 0829486

  67. Marker for terminal blocks UCT-TMF 3,5 CUS - 0829644

  68. Crimping pliers CRIMPFOX CENTRUS 6S - 1213144

  69. Crimping pliers CRIMPFOX CENTRUS 10S - 1213154

  70. Crimping pliers CRIMPFOX CENTRUS 6H - 1213146

  71. Crimping pliers CRIMPFOX CENTRUS 10H - 1213156

  72. Crimping pliers CRIMPFOX 10S - 1212045

  73. Crimping pliers CRIMPFOX 6H - 1212046

  74. Crimping pliers CRIMPFOX 2,5-M - 1212719

  75. Crimping pliers CRIMPFOX 6-M - 1212720

  76. Crimping pliers CRIMPFOX 6 - 1212034

  77. Crimping pliers CRIMPFOX 6T - 1212037

  78. Crimping pliers CRIMPFOX 6T-F - 1212038

  79. Crimping pliers CRIMPFOX 6S-F - 1212043

  80. Crimping pliers CRIMPFOX-M - 1212072

  81. Zack marker strip ZB 3,5:UNBEDRUCKT - 0829414

  82. Zack marker strip ZB 3,5 CUS - 0829415

  83. Zack marker strip ZB 3,5,LGS:FORTL.ZAHLEN - 0801404

  84. Zack marker strip ZB 3,5,QR:FORT.ZAHLEN - 0801405

  85. Marker for terminal blocks UCT-TM 3,5 - 0829484

  86. Marker for terminal blocks UCT-TM 3,5 CUS - 0829581

  87. Sensor/actuator terminal block PTIO-IN 2,5/4-PE OG - 3244481


Your advantages

The compact design and front connection enable wiring in a confined space
In addition to the testing facility in the double function shaft, all terminal blocks provide an additional test connection
The Push-in connection terminal blocks are characterized by the system features of the CLIPLINE complete system and by easy and tool-free wiring of conductors with ferrules or solid conductors