The modular 3-phase hybrid motor starter with reversing function and current monitoring provides the following functions: - Forward running - Reverse running - Motor overload protection Additional advantages are provided by using the DIN rail connector adapter (Item No. 2203861): - Power can also be supplied via the DIN rail connector by a system power supply (e. g., QUINT4-SYS...) or via the PCB connector IMC 1,5/ 5-ST-3,81, Item No. 1857919 - Optional relay module (e. g., EM-2RSC/21AU-R/L-P, Item No. 2908701) provides additional status information Thanks to the internal interlocking circuit and load wiring, wiring expense is reduced to a minimum.
    
  
  ELR H5-I-PT- 24DC/500AC-9-P02
   - 
  Hybrid motor starter
    
      1160740
      
      
    
  
      Modular hybrid motor starter for starting and reversing motors incl. motor protection and rotary field monitoring, input: 24 V DC, output: 3~, 500 V AC, 9 A, connection method: Push-in connection
Product details
| Product type | Hybrid motor starters | 
| Product family | CONTACTRON | 
| Operating mode | 100% operating factor | 
| Number of phases | 3 | 
| Motor starter type | Reversing starter | 
| Switching frequency | ≤ 2 Hz (Load-dependent) | 
| Switching frequency | ≤ 2 Hz (Load-dependent) | 
| Maximum power dissipation | 7 W | 
| Minimum power dissipation | 0.88 W | 
| Coordination type | 1 | 
| Supply | |
| Rated control circuit supply voltage US | 24 V DC | 
| Control supply voltage range | 19.2 V DC ... 30 V DC | 
| Rated control supply current IS | 60 mA | 
| Protective circuit | Surge protection | 
| Reverse polarity protection; Parallel polarity protection diode | |
| Insulation characteristics | |
| Rated insulation voltage | 550 V | 
| Rated surge voltage | 6 kV | 
| Overvoltage category | III | 
| Degree of pollution | 2 | 
| Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit | Safe isolation (IEC 60947-1) | 
| Isolation characteristics between the control input and control supply voltage to auxiliary circuit | Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC | 
| Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC | |
| Emergency tripping | |
| Operate threshold | > 60 A | 
| Response time | < 0.5 s | 
| Control | |
| Input name | Control input right/left | 
| Rated actuating voltage UC | 24 V DC | 
| Triggering voltage range | 19.2 V DC ... 30 V DC | 
| Rated actuating current IC | 7 mA | 
| Switching threshold | 9.6 V (“0” signal) | 
| 19.2 V (“1” signal) | |
| Typical turn-off time | < 30 ms | 
| Protective circuit | Reverse polarity protection | 
| AC output | |
| Rated operating voltage Ue | 500 V AC | 
| Operating voltage range | 42 V AC ... 550 V AC | 
| Rated operating current Ie | 9 A (AC-51) | 
| 7 A (AC-53a) | |
| Mains frequency | 50/60 Hz | 
| Load current range | 1.5 A ... 9 A | 
| Trigger characteristic in acc. with IEC 60947-4-2 | Class 10 (≤ 3 A) | 
| Class 10A (> 3 A) | |
| Cooling time | 20 min (for auto reset) | 
| Leakage current | 0 mA | 
| Protective circuit | Surge protection; Varistor | 
| Acknowledge output | |
| Note | Confirmation: floating change-over contact, signal contact | 
| Contact switching type | 1 changeover contact | 
| Switching capacity in accordance with IEC 60947-5-1 | 2 A (24 V (DC13)) | 
| Control circuits | |
| Connection method | Push-in connection | 
| Stripping length | 10 mm | 
| Conductor cross-section rigid | 0.2 mm² ... 2.5 mm² | 
| Conductor cross-section flexible | 0.2 mm² ... 2.5 mm² | 
| Conductor cross-section AWG | 24 ... 14 | 
| Load circuit | |
| Connection method | Push-in connection | 
| Stripping length | 10 mm | 
| Conductor cross-section rigid | 0.2 mm² ... 2.5 mm² | 
| Conductor cross-section flexible | 0.2 mm² ... 2.5 mm² | 
| Conductor cross-section AWG | 24 ... 14 | 
| Status display | LED (yellow) | 
| Operating voltage display | Green LED | 
| Error indication | Red LED | 
| Width | 22.5 mm | 
| Height | 107.5 mm | 
| Depth | 114 mm | 
| Flammability rating according to UL 94 (Housing) | V0 (Housing) | 
| Ambient conditions | |
| Degree of protection | IP20 | 
| Ambient temperature (operation) | -25 °C ... 70 °C (observe derating) | 
| Ambient temperature (storage/transport) | -40 °C ... 80 °C | 
| Altitude | ≤ 2000 m | 
| UKCA | |
| Certificate | UKCA-compliant | 
| UL data | |
| Horsepower ratings | 2 hp (208 V AC) | 
| 2 hp (230 V AC) | |
| 2 hp (240 V AC) | |
| 5 hp (480 V AC) | |
| Standards/regulations | |
| Standards/regulations | EN 60947-1 | 
| EN 60947-4-2 | |
| Mounting type | DIN rail mounting | 
| Assembly note | alignable, for spacing see derating | 
| Mounting position | vertical (horizontal DIN rail, motor output below) | 
| Item number | 1160740 | 
| Packing unit | 1 pc | 
| Minimum order quantity | 1 pc | 
| Note | Made to order (non-returnable) | 
| Sales key | CK7 | 
| Product key | DK7424 | 
| GTIN | 4063151168667 | 
| Weight per piece (including packing) | 303.6 g | 
| Weight per piece (excluding packing) | 303.6 g | 
| Customs tariff number | 85371098 | 
| Country of origin | DE | 
ECLASS
| ECLASS-13.0 | 27370905 | 
| ECLASS-15.0 | 27370905 | 
ETIM
| ETIM 9.0 | EC001037 | 
UNSPSC
| UNSPSC 21.0 | 25173900 | 
| EU RoHS | |
| Fulfills EU RoHS substance requirements | Yes | 
| Exemption | 7(a), 7(c)-I | 
| China RoHS | |
| Environment friendly use period (EFUP) | 
              EFUP-50
               An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required. 
             | 
          
| EU REACH SVHC | |
| REACH candidate substance (CAS No.) | Lead (CAS: 7439-92-1) | 
| SCIP | fb1a1644-7e14-4732-bc87-4233f365184e | 
Compatible products
- 
    
      
BRIDGE-PT 1 - Bridge 1161777
 - 
    
      
BRIDGE-PT 2 - Bridge 2904490
 - 
    
      
BRIDGE-PT 3 - Bridge 2904491
 - 
    
      
BRIDGE-PT 4 - Bridge 2904492
 - 
    
      
BRIDGE-PT 5 - Bridge 2904493
 - 
    
      
BRIDGE-PT 6 - Bridge 2904494
 - 
    
      
BRIDGE-PT 7 - Bridge 2904495
 - 
    
      
BRIDGE-PT 8 - Bridge 2904496
 - 
    
      
BRIDGE-PT 9 - Bridge 2904497
 - 
    
      
BRIDGE-PT 10 - Bridge 2904498
 - 
    
      
BRIDGE-PT 1-1M - Bridge 1161778
 - 
    
      
BRIDGE-PT-2-1M - Bridge 1049407
 - 
    
      
BRIDGE-PT-3-1M - Bridge 1049408
 - 
    
      
BRIDGE-PT-4-1M - Bridge 1049409
 - 
    
      
BRIDGE-PT-5-1M - Bridge 1049413
 - 
    
      
BRIDGE-PT-2-2M/0,3M - Bridge 1107649
 - 
    
      
BRIDGE-PT-3-2M/0,3M - Bridge 1107650
 - 
    
      
BRIDGE-PT-4-2M/0,3M - Bridge 1107644
 - 
    
      
US-EMLP (15X5) - Plastic label 0828790
 - 
    
      
UC-EMLP (15X5) - Plastic label 0819301
 - 
    
      
ELR-TBUS-22,5-P - DIN rail bus connector 2908702
 - 
    
      
QUINT4-SYS-PS/1AC/24DC/2.5/SC - Power supply 2904614
 - 
    
      
ME 17,5 TBUS 1,5/ 5-ST-3,81 GN - DIN rail bus connector 2709561
 - 
    
      
EM-2RSC/21AU-R/L-P - Extension module 2908701
 - 
    
      
EM-2RPT/21AU-R/L-P - Extension module 2909573
 - 
    
      
PSR-MC38-2NO-1DO-24DC-SC - Safety relays 1009831
 - 
    
      
PSR-MC38-2NO-1DO-24DC-PI - Safety relays 1009832
 - 
    
      
PSR-TBUS - DIN rail bus connector 2890425
 - 
    
      
MC 1,5/ 5-ST-3,81 - PCB connector 1803604
 - 
    
      
IMC 1,5/ 5-ST-3,81 - PCB connector 1857919