Axioline E, IO-Link master and digital I/O device, PROFINET, M12 connector, D-coded, IO-Link ports Class A: 4, connection method: M12 connector, A-coded, connection technology: 3-conductor, Digital inputs at pin 2 for class A ports: 4, 24 V DC, connection technology: 3-conductor, Digital inputs: 8, 24 V DC, connection technology: 4-conductor, Digital outputs: 8, 24 V DC, 500 mA, connection technology: 3-conductor, degree of protection: IP65/IP67/IP69
I/O systems
Inline, Communication module, M-Bus master; Transmission speed: 300 Baud ... 19200 Baud; transmission speed in the local bus: 500 kbps; degree of protection: IP20; for the connection of M-Bus devices; Scope of supply: including Inline connectors and marking fields
Axioline Smart Elements, Digital input module, Digital inputs: 4, 48 V DC ... 60 V DC, connection technology: 2-conductor, in accordance with IEC 61850-3, degree of protection: IP20
Inline, Digital output terminal, Digital outputs: 4, 24 V DC, connection technology: 3-conductor, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connector and labeling field
Axioline P, Analog input module, Passive analog inputs: 8 (HART), 0 mA ... 20 mA, 4 mA ... 20 mA, connection technology: 2-conductor, transmission speed in the local bus: 100 Mbps, HART functionality, intrinsically safe, degree of protection: IP20, including bus base module and Axioline P connectors
Inline segment terminal block, complete with accessories (connector and labeling field), 24 V DC, with fuse and diagnostics
Axioline F, Bus coupler, PROFIBUS DP, D-SUB-9 female connector, Extreme conditions version, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connector
Axioline F, Digital output module, Digital outputs: 4, 21 V, connection technology: 2-conductor, Solenoid drive, Extreme conditions version, intrinsically safe, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors
PLCnext Control Extension, Function module, Left alignment, Protective function, Measurement of the grid parameters, Event logging; BO0 ... BO4: 5;, Input voltage range: 380 V AC...998 V AC (50/60 Hz, nominal voltage); degree of protection: IP20; Connection to the controller via the PMP app (download from the PLCnext Store); Supported controller: AXC F 2152, AXC F 3152
Axioline F, Backplane, 4 slots for Axioline Smart Elements, transmission speed in the local bus: 100 Mbps, degree of protection: IP20