Controller - ILC 191 ME/INC
2700075

Inline controller with integrated pulse/direction/PWM interface, RS-485/RS-422, fast counters, and incremental encoder inputs, with programming options according to IEC 61131-3

Downloads

Product Details


The ILC 191 ME/INC modular small-scale controller for the Inline I/O system is at the heart of Easy Automation. The new ILC 1X1 series is characterized by its support for the Modbus/TCP and PROFINET Ethernet-based protocols. A new feature is the support for an optional SD card. The controller already has 8 digital inputs and 4 outputs, a two-channel pulse/direction/PWM interface, an integrated RS-232 interface and RS-485/RS-422 interface, a two-channel fast counter with a cut-off frequency of up to 200 kHz, and two incremental encoder inputs for asymmetrical incremental encoders.



Utilization restriction
EMC note EMC: class A product, see manufacturer's declaration in the download area

Type Inline format with alignable I/Os
Product type Controller
Display
Diagnostics display No

Transmission medium Copper
Maximum power dissipation for nominal condition max. 8.4 W
Supply
Supply voltage 24 V DC
Supply voltage range 19.2 V DC ... 30 V DC
Residual ripple ± 5 %
Typical current consumption 350 mA
Real-time clock
Realtime clock Yes
Description realtime clock Integrated (rechargeable battery buffered)
Potentials
Supply voltage 7.5 V DC ±5 %
max. 0.8 A DC (observe derating)
Potentials
Supply voltage 24 V DC -15 % / +20 %
Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
0.5 A DC (observe derating)
Potentials
Supply voltage 24 V DC -15 % / +20 % (according to EN 61131-2)
Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
max. 8 A DC (sum of UM + US)
Current draw max. 8 A DC
Potentials
Supply voltage 24 V DC -15 % / +20 % (according to EN 61131-2)
Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
max. 8 A (sum of UM + US)
Current draw max. 8 A DC

Encoder
Input name Encoder input
Number of inputs 2 (3-coil, asymmetrical)
Input voltage range "1" signal 5 V DC ... 24 V DC
Digital
Input name Digital inputs
Description of the input EN 61131-2 type 1 NPN/PNP
Number of inputs 8
Connection method Inline potential distributor
Connection technology 2-, 3-, 4-conductor
Input voltage range -0.5 V ... 30 V
Input voltage range "0" signal -0.5 V ... 5 V
Input voltage range "1" signal 15 V ... 30 V
Typical response time min. 3 ms
Counter
Input name Counter input for 24 V signals
Number of inputs 2
Input voltage range "1" signal 5 V DC ... 24 V DC
Input frequency 200 kHz

Digital
Output name Digital outputs
Connection method Spring-cage connection
Connection technology 2-, 3-, 4-conductor
Number of outputs 4
Output voltage 24 V DC
Maximum output current per channel 500 mA
Pulse direction
Output name Pulse directional output for 5 V signals
Number of pulse direction outputs 2 (can be used as an alternative to pulse width modulation)
Output voltage 5 V
Limit frequency 150 kHz

Inline connector
Connection method Spring-cage connection
Conductor cross section, rigid 0.08 mm² ... 1.5 mm²

Web server yes
Ethernet 10Base-T/100Base-TX
Bus system RJ45
Number of interfaces 2
Connection method RJ45 jack
Transmission speed 10/100 Mbps
INTERBUS local bus (master)
Number of interfaces 1
Connection method Inline data jumper
Transmission speed 500 kBaud / 2 MBaud (can be switched)
Parameterization/operation/diagnostics
Bus system RS-232
Number of interfaces 1
Connection method 6-pos. MINI DIN socket (PS/2)
Transmission speed max. 115.2 kbps
Transmission physics Copper
No. of channels 1
RS-422/-485
Bus system RS-485/-422
Number of interfaces 1
Connection method 4-pos. for full duplex
2-pos. for half duplex

Processor Altera Nios II 64 MHz
Retentive data storage 48 kByte (NVRAM)
IEC 61131 runtime system
Program memory 1 Mbyte
Data storage 1 Mbyte
Number of control tasks 8
INTERBUS-Master
Amount of process data max. 4096 Bit (INTERBUS)
Number of supported devices max. 128
Number of local bus devices that can be connected max. 63 (observe current consumption)
Number of devices with parameter channel max. 24
Number of supported branch terminals with remote bus branch max. 3
Modbus/TCP-Client
Amount of process data max. 32768 Bit (internal Modbus /TCP client)
Number of Modbus/TCP clients max. 16 later than FW 4.42
PROFINET
Device function PROFINET device
Function
Diagnostics display No
Controller redundancy No
Safety function No

Functionality
Programming languages supported Programming in acc. with IEC 61131-3
System requirements
Engineering tool PC Worx
PC Worx Express
Configuration tool Config+ Version 1.01 or later
Diagnostics tool DIAG+
Runtime system eCLR
Application interface OPC

Width 164 mm
Height 136.8 mm
Depth 71.5 mm

Color green

Ambient conditions
Degree of protection IP20
Ambient temperature (operation) -25 °C ... 55 °C
Ambient temperature (storage/transport) -25 °C ... 85 °C
Permissible humidity (operation) 10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport) 10 % ... 95 % (according to DIN EN 61131-2)
Shock 25g, Criterion 1, according to IEC 60068-2-27
Vibration (operation) 5g
Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)

Conformance with EMC directives Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, all interfaces 1 kVCriterion B, all interfaces 2 kV
Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, supply lines DC: 0.5 kV/0.5 kV (symmetrical/asymmetrical), fieldbus cable shield 1 kV
Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
Noise emission test in accordance with EN 61000-6-4/IEC 61000-6-4 EN 55011 Class A
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU

Mounting type DIN rail mounting

Item number 2700075
Packing unit 1 pc
Minimum order quantity 1 pc
Sales Key DRAAAA
Product Key DRAAAA
Catalog Page Page 82 (C-6-2017)
GTIN 4046356479103
Weight per Piece (including packing) 607.8 g
Weight per Piece (excluding packing) 450 g
Customs tariff number 85371091
Country of origin DE


ECLASS

ECLASS-9.0 27242207
ECLASS-10.0.1 27242207
ECLASS-11.0 27242207

China RoHS Environmentally Friendly Use Period = 50 years
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads”

Your advantages

Web server, FTP server, and Flash file system
Integrated fast counters and incremental encoder inputs
Integrated pulse/direction/PWM interface
Integrated RS-485/RS-422 interface
Numerous protocols supported such as: HTTP, FTP, SNTP, SNMP, SMTP, SQL, MySQL, etc.
Modbus/TCP server
Large program memory and data storage (1024 kB/1024 kB)
Modbus/TCP-Client
PROFINET-Device
HTML 5
Free engineering with PC Worx Express (IEC 61131-3)