AXL F DO4/3 AC 1F
-
Digital module
2702068
Axioline F, Digital output module, Digital outputs: 4 (Triac outputs with zero voltage switch), 230 V AC, 2 A, connection technology: 3-conductor, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors
Free download available.
Downloads
Product details
Dimensional drawing |
|
Width | 53.6 mm |
Height | 126.1 mm |
Depth | 54 mm |
Note on dimensions | The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715). |
Note on application | |
Note on application | Only for industrial use |
Axioline F local bus | |
Number of interfaces | 2 |
Connection method | Bus base module |
Transmission speed | 100 Mbps |
Module | |
Input address area | 0 Byte |
Output address area | 1 Byte |
Required parameter data | 1 Byte |
Required configuration data | 6 Byte |
Digital: | |
Output name | Digital outputs |
Connection method | Push-in connection |
Connection technology | 3-conductor |
Number of outputs | 4 (Triac outputs with zero voltage switch) |
Protective circuit | External protection required; I2t-value (a half-wave): 340 A2s |
Output voltage | 230 V AC |
Maximum output current per module | 8 A (provide external protection) |
Nominal output voltage | 230 V AC |
Output voltage range | 24 V AC ... 230 V AC -20 % / +15 % (50/60 Hz) |
Load min. | 5.1 kΩ (at 230 V) |
Output voltage when switched off | see diagram |
Nominal load, ohmic | max. 460 W (at nominal voltage) |
Switching frequency | max. 100 per second (with ohmic load) |
Reverse voltage resistance to short pulses | Reverse voltage proof |
Behavior with overload | Output may be damaged |
Signal delay | max. 10 ms (at 50 Hz) |
Product type | I/O component |
Product family | Axioline F |
Type | block modular |
Mounting position | any (observe temperature and current derating) |
Scope of supply | including bus base module and Axioline F connectors |
Maximum power dissipation for nominal condition | 8.6 W |
Potentials: Axioline F local bus supply (UBus) | |
Supply voltage | 5 V DC (via bus base module) |
Current draw | max. 120 mA |
Potentials: Supply for digital output modules (UO) | |
Supply voltage | 230 V AC |
Supply voltage range | 12 V AC ... 253 V AC (including all tolerances, including ripple, 50 ... 60 Hz) |
Current draw | max. 8 A (provide external protection) |
Protective circuit | Surge protection; Varistor 275 V |
Electrical isolation/isolation of the voltage ranges | |
Test voltage: I/Os / logic | 4 kV |
5 kV | |
Test voltage: I/O/functional ground | 4 kV |
5 kV | |
Test voltage: I/O area AC / PE | 4 kV |
Connection technology | |
Connection name | Axioline F connector |
Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. When selecting the cables, please note that in the case of a small conductor cross section and high current, the terminal point temperature may be up to 30 K above the ambient temperature. |
Conductor connection | |
Connection method | Push-in connection |
Conductor cross section rigid | 0.5 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.5 mm² ... 1.5 mm² |
Conductor cross section AWG | 20 ... 16 |
Stripping length | 8 mm |
Axioline F connector | |
Connection method | Push-in connection |
Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. When selecting the cables, please note that in the case of a small conductor cross section and high current, the terminal point temperature may be up to 30 K above the ambient temperature. |
Conductor cross section, rigid | 0.5 mm² ... 1.5 mm² |
Conductor cross section, flexible | 0.5 mm² ... 1.5 mm² |
Conductor cross section AWG | 20 ... 16 |
Stripping length | 8 mm |
Ambient conditions | |
Ambient temperature (operation) | -25 °C ... 60 °C (max. 2 A/channel for panel mounting on horizontal DIN rail; max. 1 A/channel for any mounting position) |
-25 °C ... 50 °C (max. 2 A/channel for any mounting position) | |
Degree of protection | IP20 |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
Mounting type | DIN rail mounting |
Mounting position | any (observe temperature and current derating) |
Item number | 2702068 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Sales key | DRI |
Product key | DRI232 |
Catalog page | Page 78 (C-6-2019) |
GTIN | 4046356933087 |
Weight per piece (including packing) | 239 g |
Weight per piece (excluding packing) | 239 g |
Customs tariff number | 85389091 |
Country of origin | DE |
ECLASS
ECLASS-13.0 | 27242604 |
ETIM
ETIM 9.0 | EC001599 |
UNSPSC
UNSPSC 21.0 | 32151600 |
EU RoHS | |
Fulfills EU RoHS substance requirements | Yes |
Exemption | 7(a), 7(c)-I |
China RoHS | |
Environment friendly use period (EFUP) |
EFUP-50
An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required.
|
EU REACH SVHC | |
REACH candidate substance (CAS No.) | Lead (CAS: 7439-92-1) |
SCIP | 369c1169-1d51-42a9-a9fa-0bb458d9fcfa |
Compatible products
Your advantages
4 digital outputs
Connection of actuators in 2- and 3-conductor technology
Device rating plate stored
Diagnostic and status indicators