Engine starter - PB IP 400 ME-ELR 2-3A 2734772

Module electronics, two-channel electronic motor starter, PROFIBUS-DP connection, electronic motor monitoring can be used to switch on/off a three-phase asynchronous motor

Product Details




Digital: Digital inputs
Number of inputs 4
Connection method M12 connector, (A-coded)
Connection technology 3, 4-wire
Number of positions 5
Input voltage 24 V DC (US1)
Input voltage range "0" signal -30 V ... 5 V (binary "0")
Input voltage range "1" signal 13 V ... 30 V (binary "1")
Filter time 3 ms
Typical input current per channel approx. 5 mA (for US1 = 24 V)

Utilization restriction
EMC note EMC: class A product, see manufacturer's declaration in the download area
Environmental Product Compliance
China RoHS Environmentally Friendly Use Period = 50 years
China RoHS For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Supply: Module electronics
Connection method POWER-COMBICON
Designation Terminal strip X13 and X15
Number of positions 2
Permissible conductor cross section 1.5 mm2 ... 4 mm2
Pg screw connection Pg16R
Supply voltage 24 V DC (US1)
Supply voltage range 20 V DC ... 30 V DC (including ripple)
Supply current typ. 0.17 A (at US1 = 24 V; plus current of digital inputs/outputs)
Ripple Permissible ripple 3.6 Vpp within the permissible voltage range
Max. current carrying capacity 16 A
Derating From 30°C 0.1A/K

Technical data
Drill hole spacing 386 mm

Dimensional drawing
The figure shows the product with lower part of the housing
Width 355 mm
Height 180 mm
Depth 100 mm
Drill hole spacing 386 mm
Note on dimensions Module electronics without lower part

Diagnostic messages
Diagnostics Mains failure, phase failure
Message Error message in the diagnostic code (bus) and display via the LED ERR on the module
Diagnostics Motor connector not plugged in, motor temperature exceeded, thermistor line short-circuited
Message Error message in the diagnostic code (bus) and display via the LED ERR on the module
Diagnostics Sensor supply failure
Message Error message in the diagnostic code (bus) and display via the LED ERR on the module
Diagnostics Overcurrent
Message Error message in the diagnostic code (bus) and display via the LED ERR on the module
Diagnostics Output stage cannot be controlled
Message Error message in the diagnostic code (bus) and display via the LED ERR on the module
Diagnostics Short-circuit or overload of the digital outputs
Message Message in the diagnostic code
Diagnostics Module error during self test
Message Message to the master

Housing material

PROFIBUS interface
Connection method M12 connector, B-coded
Designation connection point M12 connector; X30 (IN) and X31 (OUT)
Number of positions 5
Permissible conductor cross section 0.25 mm2 ... 0.75 mm2 (flexible)

Mounting type Wall mounting

Degree of protection IP54
Ambient temperature (operation) -20 °C ... 55 °C (non-condensing)
Note Notes on operation Line protection for the network supply line, max. 20 A. Observe derating of the POWER-COMBICON connector
Note Notes on operation Permitted network type TN network, TT network, IT network available on request
Air pressure (operation) 86 kPa ... 106 kPa (up to 2000 m above sea level)
Air pressure (storage/transport) 86 kPa ... 106 kPa (up to 2000 m above sea level)
Ambient temperature (storage/transport) -25 °C ... 75 °C
Permissible humidity (operation) 4 % ... 100 % (non-condensing)
Permissible humidity (storage/transport) 75 % (slight temporary condensation may sometimes appear on the housing)

Protection class I (МЭК 61140, EN 61140, VDE 0140-1)
Noise emission Test of emitted interference, housing, in acc. with EN 50081-2:1993 EN 55011:1991 class A
Air clearances and creepage distances
Air clearances and creepage distances according to EN 50178: 1998

Type Stand-Alone
Type Electronic motor starter
Diagnostics messages Mains failure, phase failure Error message in the diagnostic code (bus) and display via the LED ERR on the module
Diagnostics messages Motor connector not plugged in, motor temperature exceeded, thermistor line short-circuited Error message in the diagnostic code (bus) and display via the LED ERR on the module
Diagnostics messages Sensor supply failure Error message in the diagnostic code (bus) and display via the LED ERR on the module
Diagnostics messages Overcurrent Error message in the diagnostic code (bus) and display via the LED ERR on the module
Diagnostics messages Output stage cannot be controlled Error message in the diagnostic code (bus) and display via the LED ERR on the module
Diagnostics messages Short-circuit or overload of the digital outputs Message in the diagnostic code
Diagnostics messages Module error during self test Message to the master


Order Key 2734772
Packing unit 1 pc
Minimum order quantity 1 pc
Note Made to Order (non-returnable)
Catalog Page Page 432 (AX-2009)
GTIN 4017918911881
Weight per Piece (including packing) 3,340.0 GRM
Weight per Piece (excluding packing) 3,260.0 GRM
Customs tariff number 85389091