Data cable preassembled - VS-FSDBPS-OE-93G-LI/1,0 1419135

Assembled EtherCAT® cable, shielded, star quad, AWG 22 stranded (7-wire), RAL 6018 (yellow-green), M12 flush-type socket, 4-pos. on free conductor end, length: 1 m


Product Details




Shielded yes
UL AWM Style 21694
Cable length 1 m
Cable weight 67 kg/km
Electrical properties
Wave impedance 100 Ω ±15 Ω (at 100 MHz)
Test voltage Core/Shield 2000 V (50 Hz, 1 min.)
Nominal voltage, cable 600 V
Coupling resistance ≤ 20.00 mΩ/m (at 10 MHz)
Loop resistance ≤ 120.00 Ω/km
Cable insulation resistance ≥ 500 MΩ*km
Test voltage Core/Core 2000 V (50 Hz, 1 min.)
Signal speed 0.66 c
Signal runtime 5.3 ns/m
Cable structure
External sheath, color green RAL 6018
green RAL 6018
Outer sheath, material PVC
PVC
External cable diameter 6.5 mm ±0.2 mm
Single wire, color White, yellow, blue, orange
Wire diameter incl. insulation 1.55 mm
Cable structure 1x4xAWG22/7; SF/TQ
Cable abbreviation 2YY(ST)CY
Thickness, outer sheath approx. 0.9 mm
Optical shield covering 85 %
Shielding Aluminum-coated foil, tinned copper braided shield
Cable type PROFINET PVC stranded CAT5
PROFINET PVC stranded CAT5
Signal type/category PROFINET CAT5 (IEC 11801), 100 Mbps
EtherCAT® CAT5 (IEC 11801), 100 Mbps
EtherCAT® CAT5 (IEC 11801:2002), 100 Mbps
EtherCAT® CAT5 (IEC 11801), 100 Mbps
Conductor structure signal line 7x 0.25 mm
Overall twist Star quad
AWG signal line 22
Material wire insulation PE
Material, inner sheath PVC
Cable type (abbreviation) 93B
Conductor material Tin-plated Cu litz wires
Mechanical properties
Minimum bending radius, fixed installation 3 x D
Minimum bending radius, flexible installation 7 x D
Attenuation
Damping 2.1 dB (with 1 MHz)
4 dB (at 4 МHz)
6.3 dB (at 10 MHz)
8 dB (at 16 MHz)
9 dB (at 20 МHz)
11.4 dB (at 31.25 МHz)
16.5 dB (at 62.5 МHz)
21.3 dB (at 100 MHz)
Near end crosstalk attenuation (NEXT) 80 dB (with 1 MHz)
76 dB (at 4 МHz)
70 dB (at 10 MHz)
65 dB (at 16 MHz)
63 dB (at 20 МHz)
60 dB (at 31.25 МHz)
55 dB (at 62.5 МHz)
50 dB (at 100 MHz)
Ambient conditions
Ambient temperature (operation) -40 °C ... 70 °C (cable, flexible installation)
-40 °C ... 70 °C (cable, fixed installation)
Resistance to oil Resistant to oil to a limited extent
Flame resistance according to UL 1685 (CSA FT 4)
Other resistance UV resistant According to UL 1581, Section 1200

Insertion/withdrawal cycles ≥ 100
Header 1
Type Flush-type socket, straight

Transmission medium Copper
Rated surge voltage 2.5 kV
Nominal current IN 4 A (Plug/socket in accordance with IEC 61076-2-101, cable technical data is to be observed)
Contact resistance ≤ 3 mΩ
Insulation resistance ≥ 100 MΩ
Nominal voltage UN 250 V

Contact material CuZn
Contact surface material Ni/Au
Sealing material FKM
Flammability rating according to UL 94 V0
Contact carrier material PA 6.6

Signal type/category EtherCAT® CAT5 (IEC 11801:2002), 100 Mbps
EtherCAT® CAT5 (IEC 11801), 100 Mbps
Bus system EtherCAT®

Ambient temperature (operation) -25 °C ... 85 °C (Plug / socket)
-40 °C ... 85 °C (without mechanical actuation)
Degree of protection IP67 (When plugged in)
IP65 (When plugged in)
IP65/IP67

Notes on operation The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration.
Safety note
Safety note WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
• WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
• WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product.
• The products are suitable for applications in plant, controller, and electrical device engineering.
• When operating the connectors in outdoor applications, they must be separately protected against environmental influences.
• Assembled products may not be manipulated or improperly opened.
• Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products).
• When using the product in direct connection with third-party manufacturers, the user is responsible.
• For operating voltages > 50 V AC, conductive connector housings must be grounded
• Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards.
• Observe the corresponding technical data. You will find information:
o On the product
o On the packing label
o In the supplied documentation
o Online at phoenixcontact.com/products under the product
• Only use tools recommended by Phoenix Contact
• Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products
• Ensure that the protective or functional ground has been properly connected.
• VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector
• The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12).

Standards/specifications IEC 61076-2-101

Number of positions 4
Coding D - data
Insulation characteristics
Overvoltage category II
Degree of pollution 3


Order Key 1419135
Packing unit 1 pc
Minimum order quantity 1 pc
Sales Key ABQ
Catalog Page Page 385 (C-4-2015)
GTIN 4046356540582
Weight per Piece (including packing) 90.6 GRM
Weight per Piece (excluding packing) 90.6 GRM
Customs tariff number 85444290
Country of origin DE



EAC


REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
China RoHS For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”


Your advantages

Pre-assembled with cables in various standard lengths for immediate use
Customer-specific assemblies and cable lengths can be supplied
Sealed on the cable side for optimum tightness of seal
Cable designs for all common networks and fieldbuses
For high transmission safety: shield connection to the housing with optional EMC nut