Current transducer - MCR-S-1/5-UI-DCI-NC 2814715

MCR current transducer, programmable and configurable, for measuring direct, alternating and distorted currents, input current 0...0.2 to 0...11 A, unconfigured

Product Details




Signal
Output name Voltage output / current output
Configurable/programmable Yes, unconfigured
Voltage output signal 0 V ... 10 V
Voltage output signal 2 V ... 10 V
Voltage output signal -10 V ... 10 V
Voltage output signal 0 V ... 5 V
Voltage output signal 1 V ... 5 V
Voltage output signal -5 V ... 5 V
Voltage output signal 10 V ... 0 V
Voltage output signal 10 V ... 2 V
Voltage output signal 10 V ... -10 V
Voltage output signal 5 V ... 0 V
Voltage output signal 5 V ... 1 V
Voltage output signal 5 V ... -5 V
Current output signal 0 mA ... 20 mA
Current output signal 4 mA ... 20 mA
Current output signal 20 mA ... 0 mA
Current output signal 20 mA ... 4 mA
Load/output load voltage output > 10 kΩ
Load/output load current output < 500 Ω
Switching
Output name No switching output

Measurement
Description of the input Current measuring input
Number of inputs 3
Configurable/programmable Yes, unconfigured
Input current range 0 A ... 11 A (AC/DC)
Current measuring range 0 A ... 1 A (AC/DC)
Current measuring range 0 A ... 5 A (AC/DC)
Current measuring range 0 A ... 10 A (AC/DC)
Setting range for min. input current 0 A ... 200 mA
Setting range for max. input current 0 A ... 11 A
Impulse form AC, DC or distorted currents
Overload capacity 2 x IN (continuous)
Surge strength 20 x IN (1 s)
Frequency measuring range 15 Hz ... 400 Hz
Connection method Screw connection
Operate threshold 2 % (of measuring range nominal value 1/5/10 A)
Signal
Configurable/programmable Yes

Utilization restriction
EMC note EMC: class A product, see manufacturer's declaration in the download area
Environmental Product Compliance
REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
China RoHS For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Rated insulation voltage 300 V AC (to earth)
Maximum power dissipation for nominal condition 2.2 W
Test voltage output/power supply 500 V (50 Hz, 1 min.)
Test voltage input/output 4 kV (50 Hz, 1 min.)
Test voltage input/power supply 4 kV (50 Hz, 1 min.)
Step response (10-90%) 330 ms (with AC)
Step response (10-90%) 40 ms (with DC)
Temperature coefficient, typical < 0.025 %/K
Maximum transmission error < 0.5 % (of nominal range value under nominal conditions)
Supply
Supply voltage range 20 V DC ... 30 V DC
Max. current consumption < 40 mA (without load)

Dimensional drawing
Width 22.5 mm
Height 99 mm
Depth 114.5 mm

Status display Green LED

Color green
Housing material Polyamide PA non-reinforced

Mounting type DIN rail mounting
Mounting position any

CE
Identification CE-compliant
UL, USA/Canada
Identification Class I, Zone 2, AEx nA nC IIC T4, Ex nA nC IIC T4 Gc X
Identification Class I, Div. 2, Groups A, B, C and D or Non-Hazardous Locations Only

Low Voltage Directive Conformance with Low Voltage Directive
Electromagnetic compatibility Conformance with EMC directive
Noise emission EN 61000-6-4
Noise immunity EN 61000-6-2

Degree of protection IP20
Ambient temperature (operation) -20 °C ... 60 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Altitude < 2000 m

Connection method Screw connection
Stripping length 8 mm
Screw thread M3
Conductor cross section solid 0.2 mm2 ... 2.5 mm2
Conductor cross section flexible 0.2 mm2 ... 2.5 mm2
Conductor cross section AWG 24 ... 14

Insulation characteristics
Overvoltage category III
Degree of pollution 2


Order Key 2814715
Packing unit 1 pc
Minimum order quantity 1 pc
Sales Key CK4
Catalog Page Page 230 (C-5-2019)
GTIN 4017918169275
Weight per Piece (including packing) 190.3 GRM
Weight per Piece (excluding packing) 134.1 GRM
Customs tariff number 85437090



UL Recognized

cUL Recognized

EAC

cULus Recognized

cULus Listed

UL Listed

cUL Listed


Your advantages

True r.m.s. value measurement
Device can be set via DIP switches or MCR/PI-CONF-WIN configuration software
3-way isolation