Managed Switch 2000, 6 RJ45 ports 10/100/1000 Mbps, 2 SFP ports 100/1000 Mbps, degree of protection: IP20, PROFINET Conformance-Class B, PROFINET mode preset, PROFINET status LEDs


Product Details




Transmission medium Copper
FO
Test voltage 500 V DC
Test section for one minute 500 V DC
Maximum power dissipation for nominal condition 6.46 W (US = max, Tamb = max)
Local diagnostics US1/2 Supply voltage US1, US2 Green LED
FAIL Div. LED red
LNK/ACT Link status Green LED
SPD Data transmission speed Green/orange LED
BF Bus errors LED red
SF Group error LED red
Function
Signal contact control voltage typ. 24 V DC
Supply
Supply voltage 24 V DC (redundant)
Typical current consumption 260 mA (at US = 24 V DC and 25 °C ambient temperature)
Power supply connection Via COMBICON, max. conductor cross section 2.5 mm2
Supply voltage range 19.2 V DC ... 32 V DC
Max. current consumption 350 mA (US = min, Tamb = max)
Residual ripple 3.6 VPP (within the permitted voltage range)

Height 110 mm
Width 128 mm
Depth 69 mm

Status display LEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (link/activity and speed), PROFINET status LEDs (BF, SF)

Material base plate Die-cast aluminum, corrosion-resistant
Housing material Stainless steel 1.4301

Ethernet (RJ45)
Transmission length 100 m (per segment)
No. of channels 6 (RJ45 ports)
Note on the connection method Auto negotiation and autocrossing
Connection method RJ45
Transmission speed 10/100/1000 Mbps
Signal LEDs Data receive, link status
Transmission physics Copper
SFP module
Transmission length up to 80 km (depending on the SFP module used)
No. of channels 2 (SFP ports)
Connection method SFP ports
Transmission speed 100/1000 Mbps (full duplex)
Signal LEDs Data receive, link status
Transmission physics Depending on the SFP module
Number of interfaces 2

Mounting type DIN rail

Conformity/Approvals
Noxious gas test ISA S71.04.2013 G3 Harsh Group A
UL, Canada CSA C22.2 NO. 61010-1-12, Ed. 3
UL, USA UL 61010-1, Ed. 3

Noise emission EN 61000-6-4
Conformance with EMC directives EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B
EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion A
EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A
EN 61000-6-2 EN 61000-4-5 (surge) Criterion A
EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A
EN 61000-6-2 EN 61000-6-4 (interference) Class A
EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A
Noise immunity EN 61000-6-2
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU

Air pressure (operation) 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating)
Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz
Ambient temperature (operation) -40 °C ... 70 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Degree of protection IP20
Air pressure (storage/transport) 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating)
Shock (operation) 30g (EN 60068-2-27)
Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing)
Permissible humidity (operation) 10 % ... 95 % (non-condensing)

Conductor cross section AWG 24 ... 16
Stripping length 10 mm
Note on the connection method Use only copper connecting cables providing the permitted temperature range (-40 °C ... 75 °C).
Conductor cross section, flexible 0.2 mm2 ... 2.5 mm2
Connection method Push-in spring connection
Conductor cross section, rigid 0.2 mm2 ... 1.5 mm2

General Support by phone or on-site (fee is charged)
Utilization restriction
EMC note EMC: class A product, see manufacturer's declaration in the download area
Environmental Product Compliance
REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Free from substances that could impair the application of coating Yes

Type Block design
Special properties PROFINET mode preset, PROFINET status LEDs
MTTF 357.82 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
191.24 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
25.65 Years (SN 29500 standard, temperature 70°C, operating cycle 100%)
Switch functions
Redundancy MRP (Media Redundancy Protocol)
RSTP (Rapid Spanning Tree Protocol)
FRD (Fast Ring Detection)
Large Tree Support
LACP (Link Aggregation Control Protocol)
Signal contact control voltage typ. 24 V DC
Additional functions Jumbo frames (Max. 9,600 bytes)
Transmission of MMS and GOOSE (IEC 61850-8-1)
Basic functions Store-and-forward switch, complies with IEEE 802.3
Diagnostic functions RMON History
LLDP (Link Layer Discovery Protocol)
SNMP-Traps
N:1-Portmirroring
ACD (Address Conflict Detection)
SysLog
CRC-Surveillance
Management Web-based management (HTTP/HTTPS)
Role-based user management
SNMPv1/v2/v3
Command-line interface (Telnet, SSH)
MAC address table 8k
Status and diagnostic indicators LEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (link/activity and speed), PROFINET status LEDs (BF, SF)
Time synchronization SNTP (Simple Network Time Protocol)
PROFINET device function PROFINET device
Fast Startup
IP parameterization DHCP-Client
DHCP Option 82 (Relay Agent)
DHCP server (pool-based, port-based)
BootP
DCP (Discovery and Configuration Protocol)
Filter functions Quality of Service (8 priority classes)
Class of Service
DiffServ/DSCP
Port-Priorisierung
VLAN (up to 32 VLANs)
IGMP Snooping/Querier (v1/v2)
Auto-Query-Port
Extended Multicast Filtering
PROFINET conformance class Conformance-Class B
Insulation characteristics
Protection class III (VDE 0106)
Degree of pollution 2


Order Key 1089135
Packing unit 1 pc
Minimum order quantity 1 pc
Note Made to Order (non-returnable)
GTIN 4055626891880
Weight per Piece (including packing) 797.2 GRM
Weight per Piece (excluding packing) 650.0 GRM
Customs tariff number 85176200
Country of origin DE



BSH

UL Listed

cUL Listed

PROFINET

BV

cULus Listed


Compatible Products


  1. Parameterization memory SD FLASH 512MB - 2988146

  2. Parameterization memory SD FLASH 2GB - 2988162

  3. Configuration memory FL SD FLASH/MRM - 2700270

  4. Network management software FL NETWORK MANAGER BASIC - 2702889

  5. Drivers and interfaces FL SNMP OPC SERVER V3 - 2701139

  6. Mounting rail adapter FL DIN RA - 2891053

  7. Protective cap FL RJ45 PROTECT CAP - 2832991

  8. End block E/NS 35 N - 0800886

  9. Patch cable FL CAT5 PATCH 0,5 - 2832263

  10. Patch cable FL CAT5 PATCH 1,0 - 2832276

  11. Patch cable FL CAT5 PATCH 2,0 - 2832289

  12. Data cable preassembled NBC-R4AC/10G-R4AC/10G-94F/2,0 - 1408360

  13. Data cable preassembled NBC-R4AC/10G-R4AC/10G-94F/3,0 - 1408365

  14. Data cable preassembled NBC-R4AC/1,0-93B/R4AC - 1408968

  15. Data cable preassembled NBC-R4AC/2,0-93B/R4AC - 1408969

  16. Data cable preassembled NBC-R4AC/5,0-93B/R4AC - 1408970

  17. PCB plug FKCN 2,5/ 2-ST GY7035 BD:1-2 - 1082048

  18. PCB plug FKCN 2,5/ 4-ST GY7035 BD:1-4 - 1082059

  19. SFP module FL SFP FX - 2891081

  20. SFP module FL SFP FX SM - 2891082

  21. SFP module FL SFP SX - 2891754

  22. SFP module FL SFP SX2 - 2702397

  23. SFP module FL SFP LX10-B - 1025401

  24. SFP module FL SFP LX - 2891767

  25. SFP module FL SFP LX40 - 1113081

  26. SFP module FL SFP LH - 2989912

  27. SFP module FL SFP WDM10-SET - 2702442

  28. SFP module FL SFP FE WDM20-SET - 2702439

  29. SFP module FL SFP GT - 2989420

  30. Data cable preassembled FOC-LC:PA-SC:PA-OM2:D01/1 - 1115607

  31. Data cable preassembled FOC-LC:PA-SC:PA-OM2:D01/2 - 1115605

  32. Data cable preassembled FOC-LC:PA-LC:PA-OM2:D01/1 - 1115633

  33. Data cable preassembled FOC-LC:PA-LC:PA-OM2:D01/2 - 1115634

  34. Data cable preassembled FOC-LC:PA-ST:PA-OM2:D01/1 - 1115588

  35. Data cable preassembled FOC-LC:PA-ST:PA-OM2:D01/2 - 1115587

  36. Data cable preassembled FOC-LC:PA-SC:PA-OM4:D01/1 - 1115601

  37. Data cable preassembled FOC-LC:PA-SC:PA-OM4:D01/2 - 1115600

  38. Data cable preassembled FOC-LC:PA-LC:PA-OM4:D01/1 - 1115625

  39. Data cable preassembled FOC-LC:PA-LC:PA-OM4:D01/2 - 1115624

  40. Data cable preassembled FOC-LC:PA-LC:PA-OS2:D01/1 - 1115636

  41. Data cable preassembled FOC-LC:PA-LC:PA-OS2:D01/2 - 1115629

  42. Data cable preassembled FOC-LC:PA-ST:PA-OS2:D01/1 - 1115596

  43. Data cable preassembled FOC-LC:PA-ST:PA-OS2:D01/2 - 1115595

  44. Data cable preassembled FOC-LC:PA-SC:PA-OS2:D01/1 - 1115618

  45. Data cable preassembled FOC-LC:PA-SC:PA-OS2:D01/2 - 1115617


Your advantages

Configuration memory
Web-based management, SNMP
PROFINET mode preset
RSTP
DHCP client, DHCP server (pool-based and port-based), DHCP option 82
VLANs
MRP (client and manager)
-40°C ... +70°C ambient temperature