DEK-OV- 5DC/240AC/800 - Solid-state relay terminal block
2964623

Power solid-state relay terminal block, input: 5 V DC, output: 10 - 253 V AC/800 mA, terminal block width: 6.2 mm


Product Details




Order information: The housing is open on one side. The appropriate cover is D-DEK 1,5 GN (2716949).
Note on application Use of EB 80-DIK... bridges in the DEK terminal blocks: Absorption of humidity from the ambient air as well as an unfavorable tolerance between a larger number of DEK terminal blocks and the EB 80-DIK... bridge may cause (minor) expansion of the DEK housing. When the EB 80-DIK... bridges are used, therefore, it is recommended that these be disconnected after about 10 to 12 DEK terminal blocks and a wire bridge to the next DEK terminal block be inserted in their place.

Product type Solid-state relay module
Product family DEK
Application Output function
Operating mode 100% operating factor
Insulation characteristics
Insulation Basic insulation
Insulation characteristics: Standards/regulations
Insulation Basic insulation
Overvoltage category III
Pollution degree 2

Test voltage (Input/output) 2.5 kV AC (50 Hz, 1 min., input/output)

Nominal input voltage UN 5 V DC
Input voltage range in reference to UN 0.8 ... 1.2
Input voltage range 4 V DC ... 6 V DC
Switching threshold "0" signal in reference to UN ≤ 0.4
Switching threshold "1" signal in reference to UN ≥ 0.8
Typical input current at UN 10.2 mA
Typical response time < 10 ms
Typical turn-off time < 10 ms
Operating voltage display Yellow LED
Protective circuit Reverse polarity protection; Polarity protection diode
Surge protection
Transmission frequency 10 Hz

Contact type 1 N/O contact
Design of digital output electronic
Output voltage range 10 V AC ... 253 V AC (50/60 Hz)
Limiting continuous current 0.8 A (see derating curve)
Maximum inrush current 30 A (t = 10 ms)
Min. load current 10 mA
Leakage current 1.2 mA
Surge current 30 A (t = 10 ms)
Phase angle cos phi min 0.5
Max. load value 4.5 A2s
Peak offstate voltage 600 V (Periodic peak reverse voltage)
Voltage drop at max. limiting continuous current ≤ 1 V
Output circuit 2-conductor floating, zero voltage switch
Protective circuit RCV circuit; RCV circuit

Connection method Screw connection
Stripping length 8 mm
Screw thread M3
Conductor cross section solid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 14
Tightening torque 0.5 Nm

Width 6.2 mm
Height 80 mm
Depth 56 mm

Ambient conditions
Ambient temperature (operation) -20 °C ... 60 °C
Ambient temperature (storage/transport) -20 °C ... 70 °C

Standards/regulations
Standards/regulations IEC 60947-5-1

Mounting type DIN rail mounting
Assembly instructions in rows with zero spacing
Mounting position any

Item number 2964623
Packing unit 1 pc
Minimum order quantity 1 pc
Sales Key C05
Product Key CK61D2
Catalog Page Page 443 (C-5-2019)
GTIN 4017918130909
Weight per Piece (including packing) 21.071 g
Weight per Piece (excluding packing) 21.071 g
Customs tariff number 85364190
Country of origin CN


ECLASS

ECLASS-9.0 27371604
ECLASS-10.0.1 27371604
ECLASS-11.0 27371604

ETIM

ETIM 8.0 EC001504

UNSPSC

UNSPSC 21.0 39122300

EAC

Approval ID: TR_TS_D_00573_c

EAC

Approval ID: RU*C-DE.*08.B.00010

REACh SVHC Lead 7439-92-1
Hexahydromethylphthalic anhydride
China RoHS Environmentally Friendly Use Period = 50 years
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads”

Compatible Products

Your advantages

EB-DIK insertion bridges
Actuator version available
Labeling and mounting with user-friendly modular terminal blocks
Wear-free switching of up to 24 V DC/10 A or 240 V AC/800 mA
Integrated output protective circuit
Zero voltage switch at AC output
Status indicator
Integrated input circuit
Electrical isolation between input and output at up to 2.5 kVrms