DEK-OV- 12DC/ 24DC/ 10 - Solid-state relay terminal block
2961749

Power solid-state relay terminal block, input: DC voltage, output: DC voltage, input voltage: 12 V DC


Product Details




Order information: The housing is open on one side. The appropriate cover is D-DEK 1,5 GN (2716949).
Note on application Use of EB 80-DIK... bridges in the DEK terminal blocks: Absorption of humidity from the ambient air as well as an unfavorable tolerance between a larger number of DEK terminal blocks and the EB 80-DIK... bridge may cause (minor) expansion of the DEK housing. When the EB 80-DIK... bridges are used, therefore, it is recommended that these be disconnected after about 10 to 12 DEK terminal blocks and a wire bridge to the next DEK terminal block be inserted in their place.

Product type Solid-state relay module
Product family DEK
Application Output function
Operating mode 100% operating factor
Insulation characteristics
Insulation Basic insulation
Insulation characteristics: Standards/regulations
Insulation Basic insulation
Overvoltage category III
Pollution degree 2

Test voltage (Input/output) 2.5 kV AC (Input/output)

Nominal input voltage UN 12 V DC
Input voltage range in reference to UN 0.8 ... 1.2
Input voltage range 9.6 V DC ... 14.4 V DC
Switching threshold "0" signal in reference to UN ≤ 0.4
Switching threshold "1" signal in reference to UN ≥ 0.8
Typical input current at UN 4.7 mA
Typical response time 250 µs
Typical turn-off time 800 µs
Operating voltage display Yellow LED
Protective circuit Reverse polarity protection
Surge protection
Transmission frequency 100 Hz

Contact type 1 N/O contact
Design of digital output electronic
Output voltage range 5 V DC ... 30 V DC
Limiting continuous current 10 A (see derating curve)
Surge current 100 A (t = 20 ms)
Voltage drop at max. limiting continuous current < 50 mV
Output circuit 3-conductor, ground-referenced
Protective circuit Reverse polarity protection
Surge protection

Connection method Screw connection
Stripping length 8 mm
Screw thread M3
Conductor cross section solid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 14
Tightening torque 0.5 Nm

Width 6.2 mm
Height 80 mm
Depth 56 mm

Ambient conditions
Ambient temperature (operation) -20 °C ... 60 °C
Ambient temperature (storage/transport) -20 °C ... 70 °C

Standards/regulations
Standards/regulations IEC 60947-5-1

Mounting type DIN rail mounting
Assembly instructions in rows with zero spacing
Mounting position any

Item number 2961749
Packing unit 1 pc
Minimum order quantity 1 pc
Sales Key C05
Product Key CK61D2
Catalog Page Page 443 (C-5-2019)
GTIN 4017918927943
Weight per Piece (including packing) 25.34 g
Weight per Piece (excluding packing) 25.34 g
Customs tariff number 85364190
Country of origin CN


ECLASS

ECLASS-9.0 27371604
ECLASS-10.0.1 27371604
ECLASS-11.0 27371604

ETIM

ETIM 8.0 EC001504

UNSPSC

UNSPSC 21.0 39122300

cUL Recognized

Approval ID: FILE E 238705

UL Recognized

Approval ID: FILE E 238705

EAC

Approval ID: TR_TS_D_00573_c

cULus Recognized


REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads”

Compatible Products

Your advantages

EB-DIK insertion bridges
Actuator version available
Labeling and mounting with user-friendly modular terminal blocks
Wear-free switching of up to 24 V DC/10 A or 240 V AC/800 mA
Integrated output protective circuit
Electrical isolation between input and output at up to 2.5 kVrms
Zero voltage switch at AC output
Integrated input circuit
Status indicator