The CATAN DOI8 UOI8 UI8 extension module is housed in a compact DIN rail-mounted housing with an overall width of just 6 HP. It expands a Catan controller by 8 universal inputs, 8 universal outputs, and 8 digital outputs, which can alternatively be used for the digital input or counter function. The universal inputs are suitable for temperature sensors, 0 V ... 10 V interfaces, or as counters, among other things. The universal outputs can be used as 0 V ... 10 V interfaces, for example for controlling valves and fans.
CATAN DOI8 UOI8 UI8
-
Input/output module
1818583
Extension module for Catan controller. 8 universal inputs, 8 universal and 8 digital outputs. Local override operation via Catan Control Panel. Connection to the Catan controller via Single Pair Ethernet.
Product details
| Dimensions without display connected | |
| Width | 89.7 mm |
| Height | 60.7 mm |
| Length | 107.6 mm |
| Horizontal pitch | 6 Div. (DIN rail housing in accordance with DIN 43871) |
| Dimensions with display connected | |
| Width | 89.7 mm |
| Height | 68 mm |
| Length | 107.6 mm |
| Note on application | |
| Note on application | Only for industrial use |
| Extension bus (link bus) | |
| Number of interfaces | 2 (for extension modules) |
| Connection method | Push-in connection |
| Note on the connection method | Single Pair Ethernet (SPE) 10BASE-T1L, shielded |
| Transmission speed | 10 Mbps |
| Transmission length | max. 350 m (between two devices) |
| Connection for Catan Control Panel | |
| Number of interfaces | 1 |
| Connection method | USB 2.0 full speed, socket type C |
| Transmission speed | max. 12 Mbps |
| Analog: Universal input | |
| Input name | Analog current inputs |
| Current input signal | 0 mA ... 20 mA |
| 4 mA ... 20 mA | |
| Tolerance, absolute (mA) | max. 0.05 mA (The measurement requires an external parallel resistor of 68 Ω.) |
| Resolution (current) | 0.01 mA |
| Protective circuit | Surge protection |
| Analog: Universal input | |
| Input name | Analog voltage inputs |
| Voltage input signal | 0 V ... 10 V |
| Input resistance of voltage input | > 5 MΩ |
| Tolerance, absolute (V) | max. 3 mV |
| Resolution (voltage) | 1 mV |
| Protective circuit | Surge protection |
| Analog: Universal input | |
| Input name | Analog temperature inputs |
| Usable sensor type (RTD) | Pt 1000 |
| Temperature range | -100 °C ... 500 °C |
| Tolerance, absolute | max. 0.5 K |
| Temperature resolution | 0.1 K |
| Analog: Universal input | |
| Input name | Analog temperature inputs |
| Usable sensor type (RTD) | Ni 1000 |
| LG-Ni 1000 | |
| Temperature range | -50 °C ... 250 °C |
| Tolerance, absolute | max. 0.5 K |
| Temperature resolution | 0.1 K |
| Analog: Universal input | |
| Input name | Analog temperature inputs |
| Usable sensor type (TC) | NTC 10k (e.g., also 10K3A1) |
| NTC 20k (e.g., also 20K6A1) | |
| NTC 10k Pre (e.g., also 10K4A1) | |
| Temperature range | -30 °C ... 150 °C (NTC 10k) |
| -15 °C ... 150 °C (NTC 20k) | |
| Tolerance, absolute | max. 0.5 K (Line resistance max. 2 Ω (30 m copper cable with d = 0.8 mm)) |
| Temperature resolution | 0.1 K |
| Analog: Universal input | |
| Input name | Analog resistance inputs |
| Tolerance, relative | max. 0.1 % (for resistances >200 Ω) |
| Resistance range | 0 Ω ... 10 kΩ |
| Resolution (resistance) | 0.01 Ω |
| Analog: Universal input | |
| Input name | Analog resistance inputs |
| Tolerance, relative | max. 1 % (for resistances >200 Ω) |
| Resistance range | 0 Ω ... 180 kΩ |
| Resolution (resistance) | 0.1 Ω |
| Digital: Universal input | |
| Input name | Digital inputs |
| Description of the input | EN 61131-2 type 2 and 3 |
| Input voltage range "0" signal | -3 V DC ... 5 V DC (An open input always provides a 0 signal.) |
| Input voltage range "1" signal | 11 V DC ... 30 V DC |
| Nominal input voltage UIN | 24 V DC |
| Digital: Universal input | |
| Input name | Floating contacts |
| Input information | Connect the contact to ground. |
| Description of the input | Open/closed contact |
| Input current | 2 mA |
| Input resistance range | > 27 kΩ |
| Digital: Digital input (DOI) | |
| Input name | “Digital input” function |
| Input information | Connect the contact to ground. |
| Recommendation: If you use sensitive contacts such as reed contacts, connect a series resistor of at least 100 Ω in series. | |
| Connection method | Push-in connection |
| Connection technology | 2-conductor |
| Input current | 1 mA |
| Input resistance range | > 27 kΩ |
| Digital: Universal output | |
| Input name | Digital inputs |
| Input information | You can parameterize each universal output as a digital input. See ““Digital input” function” table. |
| Counter: Universal input | |
| Input name | Counter inputs |
| Input frequency | max. 20 Hz (Signal is debounced) |
| Resolution | 1 Impulse |
| Counter: Digital input (DOI) | |
| Input name | Counter inputs |
| Input frequency | max. 100 Hz |
| Resolution | 1 Impulse |
| Analog: Universal output | |
| Output name | Analog voltage outputs |
| Operating mode | Sink and source |
| Output current (per channel) | max. 10 mA (Sum of the output currents in sink operating mode: < 60 mA) |
| Resolution (voltage) | 1 mV |
| Voltage output signal | 0 V ... 10 V |
| Tolerance, absolute (V) | max. 25 mV (typ.) |
| Digital: Digital output (DOI) | |
| Output name | Digital outputs with “Digital input” function (DOI) |
| Note on output | To obtain a valid voltage level for a logical "0" signal at the output, use a load resistor <1 kΩ. |
| You can parameterize each digital output for the “Digital input” function. | |
| Connection method | Push-in connection |
| Connection technology | 2-conductor |
| Number of outputs | 8 |
| Protective circuit | Short-circuit protection |
| Overload protection | |
| Protection against incorrect DC connection (max. 30 V) | |
| Output current | max. 500 mA |
| Nominal output voltage | 24 V DC |
| Output current when switched off | max. 1.4 mA |
| Nominal load, ohmic | 12 W (48 Ω) |
| Permissible cable length | max. 30 m (For compliance with the requirements in accordance with CE and to ensure compliance with the EMC Directive) |
| Reverse voltage resistance to short pulses | Reverse voltage proof |
| Behavior with overload | Auto restart |
| Behavior at voltage switch-off | The output follows the power supply without delay |
| Digital: Universal output | |
| Output name | Digital outputs |
| Note on output | The technical data is identical to the data of the digital outputs with “Digital input” function (DOI). |
| Product family | Catan |
| Installation location | indoor use |
| Mounting position | horizontal |
| Alternative mounting positions are possible, but can lead to a reduction in thermal performance. | |
| Insulation characteristics | |
| Overvoltage category | II (IEC 60664-1, EN 60664-1) |
| Pollution degree | 2 (IEC 60664-1, EN 60664-1) |
| Supply: | |
| Designation | Supply |
| Supply voltage | 24 V DC |
| Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Current consumption | max. 8.25 A |
| 100 mA (without external load) | |
| 150 mA (with display) | |
| Electrical isolation/isolation of the voltage ranges | |
| Test voltage: Extension bus/communications | 500 V AC, 50 Hz, 1 min |
| Test voltage: Logic/functional ground | 500 V AC, 50 Hz, 1 min |
| Connection technology | |
| Connection name | Connections 1 ... 19 (digital and universal outputs) |
| Connections 1 ... 19 (digital and universal outputs) | |
| Connection method | Push-in connection |
| Conductor cross-section, flexible | 0.2 mm² ... 4 mm² |
| Conductor cross-section AWG | 24 ... 12 |
| Conductor cross-section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 2.5 mm² |
| Conductor cross-section, flexible, with ferrule, without plastic sleeve | 0.25 mm² ... 2.5 mm² |
| Stripping length | 10 mm |
| Conductor cross-section, rigid | 0.2 mm² ... 4 mm² (Conductor connection with open terminal point) |
| 0.5 mm² ... 4 mm² (Push-in connection) | |
| Nominal cross section | 4 mm² |
| Connections 31 ... 62 (power supply, link bus, universal inputs) | |
| Connection method | Push-in connection |
| Conductor cross-section, flexible | 0.5 mm² ... 1.5 mm² |
| Conductor cross-section AWG | 24 ... 16 |
| Conductor cross-section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 1.5 mm² |
| Conductor cross-section, flexible, with ferrule, without plastic sleeve | 0.25 mm² ... 1.5 mm² |
| Stripping length | 10 mm |
| Conductor cross-section, rigid | 0.2 mm² ... 1.5 mm² (Conductor connection with open terminal point) |
| 0.34 mm² ... 1.5 mm² (Push-in connection) | |
| Nominal cross section | 1.5 mm² |
| Ambient conditions | |
| Ambient temperature (operation) | -5 °C ... 50 °C (up to 3000 m above mean sea level) |
| Degree of protection | IP20 |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 58 kPa ... 106 kPa (up to 4500 m above mean sea level) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
| Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
| Mounting type | DIN rail mounting (in accordance with DIN EN 60715) |
| Mounting position | horizontal |
| Item number | 1818583 |
| Packing unit | 1 pc |
| Minimum order quantity | 1 pc |
| Product key | DRHAFA |
| GTIN | 4067923448759 |
| Weight per piece (including packing) | 215.66 g |
| Weight per piece (excluding packing) | 192.91 g |
| Country of origin | Country of origin will be provided upon delivery. |
ECLASS
| ECLASS-13.0 | 27242604 |
| ECLASS-15.0 | 27242604 |
ETIM
| ETIM 9.0 | EC001599 |
Compatible products
Your advantages
Space and cost savings due to high I/O density and flexible configurability
Control of analog actuators such as valves and fans with 0 V ... 10 V interface
Commissioning and maintenance supported by the plug-in display for local operation
High-performance extension bus also enables distributed installation
Digital twin as the basis for smart buildings
PHOENIX CONTACT
586 Fulling Mill Road, Middletown, PA 17057