High-availability PLCnext controller for PROFINET networks with S2 system redundancy functionality.
When it comes to high-availability, distributed, and modular automation, PLCnext controllers with IEC 61131 control intelligence, redundancy technology, and network connection are the ideal solution. Thanks to the integrated FO-based redundancy function, you can reduce system downtimes, work cost effectively, and also avoid potential hazards. Virtual IP technology enables easy and user-friendly connection of SCADA systems. The integrated OPC UA server/client function allows for a cascaded topology of redundancy levels.
Please note that this controller type does not currently support the “Download Changes” function.
RFC 4072R
-
Controller
1136419
High-availability PLCnext controller with redundancy functionality
Free download available.
Downloads
Product details
Note on application | |
Note on application | Only for industrial use |
Product type | Controller |
Product family | PLCnext Control |
Type | Stand-Alone |
Data management status | |
Article revision | 03 |
Insulation characteristics | |
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Pollution degree | 2 (when installed in a control cabinet or housing with IP54 degree of protection or higher) |
Display | |
Diagnostics display | yes |
Processor | Intel®Core™ i5-6300U, 2x 2.4 GHz (Standard) |
Flash memory | 100 Mbyte (internal flash memory) |
SD card from Phoenix Contact (for external flash memory, see accessories) | |
Retentive data storage | 2 Mbyte |
IEC 61131 runtime system | |
Program memory | 16 Mbyte |
Data storage system | 32 Mbyte |
PROFINET | |
Device function | PROFINET-Controller |
Number of supported devices | max. 256 |
Vendor ID | 00B0hex / 176dez |
Function | |
Diagnostics display | yes |
Controller redundancy | yes |
Safety function | no |
Functionality | |
Programming languages supported | Instruction list (IL) |
Symbolic flowchart (SFC) | |
Ladder diagram (LD) | |
Function block diagram (FBD) | |
Structured text (ST) | |
C++ | |
C# | |
Java | |
Python® | |
Simulink® | |
System requirements | |
Engineering tool | PLCnext Engineer |
Eclipse® | |
Visual Studio® | |
MATLAB®/ Simulink® | |
Application interface | OPC UA® |
OPC UA Pub/Sub |
Power consumption | typ. 25 W (Without fan module) |
max. 35 W (With fan module) | |
Maximum power dissipation for nominal condition | 25 W (Without fan module) |
Transmission medium | Copper |
FO | |
Supply | |
Supply voltage | 24 V DC |
Supply voltage range | 18 V DC ... 32.1 V DC (including ripple (3.6 VPP)) |
Power supply connection | Via COMBICON, max. conductor cross section 2.5 mm² |
Real-time clock | |
Realtime clock | integrated (capacitive buffering) |
Description realtime clock | 1.73 s/day = 20 ppm at 25 °C |
Potentials | |
Protective circuit | Surge protection of the supply voltage; electronic |
Polarity reversal protection of the supply voltage; electronic |
Tightening torque | 0.5 ... 0.6 Nm |
COMBICON connector | |
Conductor cross section, rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section, flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 12 |
Web server | yes |
USB | |
Number of interfaces | 1 |
Connection method | USB type A, socket |
Ethernet | |
Bus system | RJ45 |
Number of interfaces | 4 |
Connection method | RJ45 jack |
Note on the connection method | Auto negotiation and auto crossing, auto polarity exchange |
Transmission speed | 10/100/1000 Mbps (LAN 1/LAN 2, half duplex or full duplex) |
10/100 Mbps (LAN3.1/LAN3.2 (internally switched), half duplex or full duplex) |
External dimensions | |
Width / Height / Depth | 122 mm / 182 mm / 173 mm (without fan module) |
122 mm / 220 mm / 173 mm (With fan module) |
Color | gray (RAL 7042) |
Ambient conditions | |
Degree of protection | IP20 |
Ambient temperature (operation) | 0 °C ... 60 °C up to 2000 m above mean sea level (recommended: above 50°C with fan module) |
0 °C ... 55 °C 2000 m ... 3000 m above mean sea level (With fan module only) | |
0 °C ... 50 °C 3000 m ... 4000 m above mean sea level (With fan module only) | |
Ambient temperature (storage/transport) | -25 °C ... 70 °C |
Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
Shock (operation) | 20g (in accordance with EN 60068-2-27/IEC 60068-2-27) |
Vibration (operation) | 1g (in accordance with EN 60068-2-6/IEC 60068-2-6) |
Air pressure (operation) | 60 kPa ... 108 kPa (up to 4000 m above mean sea level) |
Air pressure (storage/transport) | 58 kPa ... 108 kPa (up to 4500 m above mean sea level) |
Resistance to gases that may endanger the functions, in acc. with DIN 40046-36, DIN 40046-37 | Use of the device in these ambient conditions is prohibited. |
Conformance with EMC directives | Immunity test in accordance with EN IEC 61000-6-2 Electrostatic discharge (ESD)IEC 61000-4-2 Criterion B, ±6 kV contact discharge, ±8 kV air discharge |
Immunity test in accordance with EN IEC 61000-6-2 Electromagnetic fieldsIEC 61000-4-3 Criterion A, Field intensity: 10 V/m | |
Immunity test in accordance with EN IEC 61000-6-2 Fast transients (burst)IEC 61000-4-4 Criterion B, Supply lines: ±2 kV, Signal/data lines: ±2 kV | |
Immunity test in accordance with EN IEC 61000-6-2 Transient overvoltage (surge)IEC 61000-4-5 Criterion B, supply lines: ±0.5 kV, signal/data cables: ±1 kV | |
Immunity test in accordance with EN IEC 61000-6-2 Conducted interferenceIEC 61000-4-6 Criterion A, Test voltage 10 V | |
Noise emission test in accordance with EN IEC 61000-6-4 Class A | |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Mounting type | DIN rail mounting |
Item number | 1136419 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Sales key | DR09 |
Product key | DRADBA |
GTIN | 4063151072230 |
Weight per piece (including packing) | 3,062 g |
Weight per piece (excluding packing) | 2,000 g |
Customs tariff number | 85371091 |
Country of origin | DE |
ECLASS
ECLASS-11.0 | 27242207 |
ECLASS-12.0 | 27242207 |
ECLASS-13.0 | 27242207 |
ETIM
ETIM 9.0 | EC000236 |
UNSPSC
UNSPSC 21.0 | 32151700 |
EU RoHS | |
Fulfills EU RoHS substance requirements | Yes |
Exemption | 6(a), 6(a)-I, 7(a), 7(c)-I |
China RoHS | |
Environment friendly use period (EFUP) |
EFUP-50
An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required.
|
EU REACH SVHC | |
REACH candidate substance (CAS No.) | Lead (CAS: 7439-92-1) |
SCIP | fb620ac8-c3b8-42b6-9454-fafe7da884fb |
Compatible products
-
SD FLASH 2GB PLCNEXT MEMORY - Program/configuration memory 1043501
-
SD FLASH 8GB PLCNEXT MEMORY - Program/configuration memory 1061701
-
SD FLASH 8GB PLCNEXT MEMORY LIC - Program/configuration memory 1151112
-
SD FLASH 32GB PLCNEXT MEMORY LIC - Program/configuration memory 1151111
-
SD FLASH PLCNEXT MEMORY LIC CFG - Program/configuration memory 1308064
-
PLCNEXT ENGINEER - Programming software 1046008
-
RFC FAN MODULE - Fan 2404085
-
FL SFP SX - Media module 2891754
-
FL SFP LX - Media module 2891767
-
FL SFP LH - Media module 2989912
-
FOC-LC:PA-LC:PA-OM2:D01/1 - FO patch cable 1115633
-
FOC-LC:PA-LC:PA-OM2:D01/2 - FO patch cable 1115634
-
FOC-LC:PA-LC:PA-OM2:D01/5 - FO patch cable 1115637
-
FOC-LC:PA-LC:PA-OS2:D01/1 - FO patch cable 1115636
-
FOC-LC:PA-LC:PA-OS2:D01/2 - FO patch cable 1115629
-
FOC-LC:PA-LC:PA-OS2:D01/5 - FO patch cable 1115626
-
PLCNEXT TECHNOLOGY TOOLCHAIN - Programming software 1639782
Your advantages
Fast startup and automatic configuration of all redundancy functions, thanks to AutoSync technology
Uninterrupted process in the event of failure or when a controller is replaced
Integrated PROFINET controller and PROFINET device
System networking M2M with OPC UA
A distance of up to 10 km between the controllers via fiber optics; cost-optimized thanks to plug-in SFP modules
Automatic switch-over of the visualization by using virtual IP technology
High-resolution display for displaying status and error messages in plain text
PROFINET standards ensure optimum device integration and S2 redundancy for your future-proof Ethernet network
PHOENIX CONTACT
586 Fulling Mill Road, Middletown, PA 17057