Circular connectors (device side) - SACCBP-MSD-4CON-PG9/5,0-931SCO 1437753

Bus system flush-type plug, Ethernet, 4-pos., M12 SPEEDCON, shielded, D-coded, rear/screw mounting with Pg9 thread, with 5.0 m bus cable, 2 x 2 x 0.2 mm2

Product Details




Mounting type Rear wall/screw mounting

Cable length 5
Shielded yes
UL AWM Style 20963 (80°C/30 V)
Cable weight 42 kg/km
Electrical properties
Current carrying capacity of cable 2 A (according to DIN VDE 0891-1)
Nominal voltage, cable ≤ 100 V (Peak value, not for high-power applications)
Test voltage Core/Core 700 V (50 Hz, 1 min.)
Test voltage Core/Shield 700 V (50 Hz, 1 min.)
Cable insulation resistance ≥ 500 MΩ*km
Coupling resistance ≤ 100.00 mΩ/m (at 10 MHz)
Wave impedance 100 Ω ±5 Ω (at 100 MHz)
Loop resistance ≤ 290.00 Ω/km
Cable capacity approx. 45 nF/km (at 1 kHz)
Signal runtime 5.3 ns/m
Cable structure
Cable abbreviation 02YS(ST)C11Y
Cable type Ethernet flexible CAT5, 2-pair
Cable type (abbreviation) 93E
Signal type/category Ethernet CAT5 (IEC 11801), 100 Mbps
Cable structure 2x2xAWG26/7; SF/UTP
External cable diameter 6.4 mm ±0.2 mm
Outer sheath, material PUR
External sheath, color water blue RAL 5021
Thickness, outer sheath 1.2 mm
Conductor material Bare Cu litz wires
Conductor structure signal line 7x 0.16 mm
AWG signal line 26
Material wire insulation Foamed PE
Wire diameter incl. insulation 0.98 mm
Single wire, color white/orange-orange, white/green-green
Twisted pairs 2 cores to the pair
Overall twist Two pairs with two fillers to the core
Shielding Aluminum-coated foil, tinned copper braided shield
Optical shield covering 70 %
Mechanical properties
Minimum bending radius, fixed installation 4 x D
Minimum bending radius, flexible installation 8 x D
Tensile strength ≤ 80 N
Attenuation
Damping 3.2 dB (with 1 MHz)
Damping 6 dB (at 4 МHz)
Damping 9.5 dB (at 10 MHz)
Damping 12.1 dB (at 16 MHz)
Damping 13.6 dB (at 20 МHz)
Damping 17.1 dB (at 31.25 МHz)
Damping 24.8 dB (at 62.5 МHz)
Damping 32 dB (at 100 MHz)
Near end crosstalk attenuation (NEXT) 65.3 dB (with 1 MHz)
Near end crosstalk attenuation (NEXT) 56.3 dB (at 4 МHz)
Near end crosstalk attenuation (NEXT) 50.3 dB (at 10 MHz)
Near end crosstalk attenuation (NEXT) 47.2 dB (at 16 MHz)
Near end crosstalk attenuation (NEXT) 45.8 dB (at 20 МHz)
Near end crosstalk attenuation (NEXT) 42.9 dB (at 31.25 МHz)
Near end crosstalk attenuation (NEXT) 38.4 dB (at 62.5 МHz)
Near end crosstalk attenuation (NEXT) 35.3 dB (at 100 MHz)
Power-summated near end crosstalk attenuation (PSNEXT) 62.3 dB (with 1 MHz)
Power-summated near end crosstalk attenuation (PSNEXT) 53.3 dB (at 4 МHz)
Power-summated near end crosstalk attenuation (PSNEXT) 47.3 dB (at 10 MHz)
Power-summated near end crosstalk attenuation (PSNEXT) 44.2 dB (at 16 MHz)
Power-summated near end crosstalk attenuation (PSNEXT) 42.8 dB (at 20 МHz)
Power-summated near end crosstalk attenuation (PSNEXT) 39.9 dB (at 31.25 МHz)
Power-summated near end crosstalk attenuation (PSNEXT) 35.4 dB (at 62.5 МHz)
Power-summated near end crosstalk attenuation (PSNEXT) 32.3 dB (at 100 MHz)
Return loss (RL) 23 dB (at 4 МHz)
Return loss (RL) 24.1 dB (at 8 МHz)
Return loss (RL) 25 dB (at 10 MHz)
Return loss (RL) 25 dB (at 16 MHz)
Return loss (RL) 25 dB (at 20 МHz)
Return loss (RL) 23.6 dB (at 31.25 МHz)
Return loss (RL) 21.5 dB (at 62.5 МHz)
Return loss (RL) 20.1 dB (at 100 MHz)
Ambient conditions
Halogen-free according to IEC 60754-1
Resistance to oil according to EN 60811-2-1
Flame resistance according to IEC 60332-1-2
Flame resistance in acc. to UL VW1
Ambient temperature (operation) -20 °C ... 80 °C (cable, flexible installation)
Ambient temperature (operation) -40 °C ... 80 °C (cable, fixed installation)

Head 2
Type free cable end
Header 1
Type Flush-type plug, straight

Rated surge voltage 2.5 kV AC
Nominal voltage UN 100 V
Nominal current IN 4 A (Plug/socket in accordance with IEC 61076-2-101, cable technical data is to be observed)

Degree of protection IP67 (When plugged in)
Degree of protection IP65 (When plugged in)
Degree of protection IP65/IP67
Ambient temperature (operation) -25 ... -85 (Plug / socket)
Ambient temperature (operation) -20 °C ... 60 °C (cable, fixed installation)
Ambient temperature (operation) 0 °C ... 50 °C (cable, flexible installation)

Connection technology
Connection method Bus line
Conductor connection
Connection method Bus line

Environmental Product Compliance
China RoHS Environmentally Friendly Use Period = 50 years
China RoHS For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Safety note
Safety note WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
Safety note • WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
Safety note • WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product.
Safety note • The products are suitable for applications in plant, controller, and electrical device engineering.
Safety note • When operating the connectors in outdoor applications, they must be separately protected against environmental influences.
Safety note • Assembled products may not be manipulated or improperly opened.
Safety note • Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products).
Safety note • When using the product in direct connection with third-party manufacturers, the user is responsible.
Safety note • For operating voltages > 50 V AC, conductive connector housings must be grounded
Safety note • Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards.
Safety note • Observe the corresponding technical data. You will find information:
o On the product
o On the packing label
o In the supplied documentation
o Online at phoenixcontact.com/products under the product
Safety note • Only use tools recommended by Phoenix Contact
Safety note • Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products
Safety note • Ensure that the protective or functional ground has been properly connected.
Safety note • VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector
Safety note • The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12).

Standards/specifications according to IEC 61076-2-101

Flammability rating according to UL 94 V0
Sealing material NBR
Contact material CuZn
Contact surface material Ni/Au
Contact carrier material PA 6.6
Cable gland material Nickel-plated brass

Number of positions 4
Coding D-coded
Insulation characteristics
Overvoltage category II
Degree of pollution 3


Order Key 1437753
Packing unit 1 pc
Minimum order quantity 1 pc
Note Made to Order (non-returnable)
GTIN 4046356458498
Weight per Piece (including packing) 222.2 GRM
Weight per Piece (excluding packing) 222.2 GRM
Customs tariff number 85444290
Country of origin DE



UL Recognized

Approval Specification Data
Nominal voltage UN 250 V
Nominal current IN 4 A
AWG/kcmil 22
Max. cross section 22 mm²

EAC