Digital module - AXL SE DO16/1
1088129

Axioline Smart Elements, Digital output module, Digital outputs: 16, 24 V DC, 500 mA, connection technology: 1-conductor, degree of protection: IP20

This product needs further products for operation. Mandatory Accessories
Free Download available. Downloads

Product Details


You can integrate Axioline Smart Elements into systems with the Smart Element interface. This Smart Element emits digital signals.



Dimensional drawing
Width 14.9 mm
Height 62.2 mm
Depth 62 mm

Utilization restriction
EMC note EMC: class A product, see manufacturer's declaration in the download area

Color traffic grey A RAL 7042

Smart Element interface
Number of interfaces 1
Connection method Card edge connector
Transmission speed See system in which you use the Smart Element.
Start time until ready to operate < 500 ms

Module
ID code (hex) none
Process data channel 16 Bit
Input address area 0 Byte
Output address area 2 Byte
Required parameter data 9 Byte
Required configuration data 6 Byte

Digital
Output name Digital outputs
Connection method Push-in connection
Connection technology 1-conductor
Number of outputs 16
Protective circuit Short-circuit and overload protection; electronic
Output voltage 24 V
Maximum output current per module 6 A (Also make sure that the maximum permissible current of 6 A is not exceeded.)
Nominal output voltage 24 V DC
Output voltage when switched off max. 1 V
Output current when switched off max. 300 µA
Nominal load, inductive 12 VA (1.2 H, 48 Ω, with nominal voltage)
Nominal load, lamp 12 W (at nominal voltage)
Nominal load, ohmic 12 W (48 Ω, with nominal voltage)
Switching frequency max. 1200 per second (With resistive load, at least 50 mA load current)
max. 1 per second (with inductive load)
max. 16 per second (with nominal lamp load)
Reverse voltage resistance to short pulses limited protection up to 0.5 A for 1 s
Behavior with overload Shutdown with automatic restart
Behavior with inductive overload Output can be destroyed

Type modular
Product type I/O component
Mounting position See the system in which the Smart Element is used.
Insulation characteristics
Overvoltage category II (IEC 60664-1, EN 60664-1)
Pollution degree 2 (IEC 60664-1, EN 60664-1)

Potentials: Communications power supply of the Smart Elements (USE)
Supply voltage using card edge connectors
Potentials: I/O supply (UP)
Supply voltage 24 V DC (using card edge connectors)
Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current draw max. 6 A
Current consumption min. 40 mA (without connected peripherals)
Power consumption max. 180 W (of which 1.1 W internal losses)
min. 288 mW
Protective circuit Surge protection; electronic (35 V, 0.5 s)
Reverse polarity protection; parallel diode

Connection technology
Connection name I/O
Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline Smart Elements” user manual.
With a small conductor cross section and high current, the terminal point temperature can reach up to 45 K above the ambient temperature.
When selecting the cables, observe the permissible operating temperature in accordance with IEC or UL.
Conductor connection
Connection method Push-in connection
Conductor cross section solid 0.25 mm² ... 1.5 mm²
Conductor cross section flexible 0.25 mm² ... 1.5 mm²
Conductor cross section AWG 24 ... 16
Conductor cross section flexible, with ferrule without plastic sleeve 0.25 mm² ... 1.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve 0.25 mm² ... 1.5 mm²
Stripping length 8 mm
I/O
Connection method Push-in connection
Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline Smart Elements” user manual.
With a small conductor cross section and high current, the terminal point temperature can reach up to 45 K above the ambient temperature.
When selecting the cables, observe the permissible operating temperature in accordance with IEC or UL.
Conductor cross section, rigid 0.25 mm² ... 1.5 mm²
Conductor cross section, flexible 0.25 mm² ... 1.5 mm²
Conductor cross section AWG 24 ... 16
Conductor cross section, flexible, with ferrule, with plastic sleeve 0.25 mm² ... 1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve 0.25 mm² ... 1.5 mm²
Stripping length 8 mm

Ambient temperature (operation) -25 °C ... 60 °C
Degree of protection IP20
Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Permissible humidity (operation) 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)

Protection class III (IEC 61140, EN 61140, VDE 0140-1)

Mounting type Smart Element slot
Mounting position See the system in which the Smart Element is used.

Item number 1088129
Packing unit 1 pc
Minimum order quantity 1 pc
Sales Key DRIB32
Product Key DRIB32
GTIN 4055626888101
Weight per Piece (including packing) 38.9 g
Weight per Piece (excluding packing) 35 g
Customs tariff number 85389091
Country of origin DE


ECLASS

ECLASS-9.0 27242604
ECLASS-10.0.1 27242604
ECLASS-11.0 27242604

ETIM

ETIM 8.0 EC001599

UNSPSC

UNSPSC 21.0 32151600

UL Listed

Approval ID: FILE E 238705

cUL Listed

Approval ID: FILE E 238705

cULus Listed


REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads”

Your advantages

16 digital outputs
24 V DC, 500 mA
Connection of actuators in 1-conductor technology
Substitute value behavior of the outputs can be parameterized for the Smart Element
Device rating plate stored