Feed-through terminal block, with six-lobe screw, nom. voltage: 1000 V, nominal current: 57 A, connection method: Screw connection, Rated cross section: 10 mm2, cross section: 0.5 mm2 - 16 mm2, mounting type: NS 35/7,5, NS 35/15, color: gray
Product type | Feed-through terminal block |
Number of connections | 2 |
Number of rows | 1 |
Potentials | 1 |
Insulation characteristics | |
Overvoltage category | III |
Degree of pollution | 3 |
Rated surge voltage | 8 kV |
Maximum power dissipation for nominal condition | 1.82 W |
Number of connections per level | 2 |
Nominal cross section | 10 mm² |
Level 1 above 1 below 1 | |
Screw thread | M4 |
Tightening torque | 1.5 ... 1.8 Nm |
Stripping length | 10 mm |
Internal cylindrical gage | A6 |
Connection in acc. with standard | IEC 60947-7-1 |
Conductor cross section solid | 0.5 mm² ... 16 mm² |
Cross section AWG | 20 ... 6 |
Conductor cross section flexible | 0.5 mm² ... 16 mm² |
Conductor cross section, flexible [AWG] | 20 ... 6 |
Flexible conductor cross section flexible (ferrule, w/o plastic sleeve) | 0.5 mm² ... 10 mm² |
Flexible conductor cross section (ferrule with plastic sleeve) | 0.5 mm² ... 10 mm² |
2 conductors with same cross section, solid | 0.5 mm² ... 4 mm² |
2 conductors with same cross section, flexible | 0.5 mm² ... 4 mm² |
2 conductors with same cross section, flexible, with ferrule without plastic sleeve | 0.5 mm² ... 2.5 mm² |
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve | 0.5 mm² ... 6 mm² |
Nominal current | 57 A |
Maximum load current | 76 A (with 16 mm² conductor cross section) |
Nominal voltage | 1000 V |
Note | Note: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area. |
Nominal cross section | 10 mm² |
Rated data (ATEX/IECEx) | |
ATEX certificate | KEMA 04 ATEX 2048 U |
IEC Ex certificate | IECEx KEM 06.0027 U |
Identification | Ex eb IIC Gb |
Operating temperature range | -60 °C ... 110 °C |
Ex-certified accessories | 3047028 D-UT 2,5/10 |
1205066 SZS 1,0X4,0 VDE | |
3022276 CLIPFIX 35-5 | |
3022218 CLIPFIX 35 | |
Plug-in bridge / FBS 2-10 / 3005947 | |
Plug-in bridge / FBS 5-10 / 3005948 | |
Bridge data | 54 A / 10 mm² |
Ex temperature increase | 40 K (60.1 A / 10 mm²) |
Rated voltage | 630 V |
for bridging with bridge | 690 V |
Rated insulation voltage | 630 V |
Ex level General | |
Rated current | 54 A |
Maximum load current | 69 A |
Contact resistance | 0.16 mΩ |
Ex connection data General | |
Torque range | 1.5 Nm ... 1.8 Nm |
Nominal cross section | 10 mm² |
Rated cross section AWG | 8 |
Connection capacity rigid | 0.5 mm² ... 16 mm² |
Connection capacity AWG | 20 ... 6 |
Connection capacity flexible | 0.5 mm² ... 10 mm² |
Connection capacity AWG | 20 ... 8 |
2 conductors with same cross section, solid | 0.5 mm² ... 4 mm² |
2 conductors with the same cross-section AWG rigid | 20 ... 12 |
2 conductors with same cross section, stranded | 0.5 mm² ... 4 mm² |
2 conductors with the same cross-section AWG flexible | 20 ... 12 |
Width | 10.2 mm |
End cover width | 2.2 mm |
Height | 46.9 mm |
Height NS 35/15 | 55 mm |
Height NS 35/7,5 | 47.5 mm |
Length | 47.7 mm |
Color | gray |
Flammability rating according to UL 94 | V0 |
Insulating material group | I |
Insulating material | PA |
Static insulating material application in cold | -60 °C |
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 125 °C |
Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
Calorimetric heat release NFPA 130 (ASTM E 1354) | 27,5 MJ/kg |
Surface flammability NFPA 130 (ASTM E 162) | passed |
Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
Surge voltage test | |
Result | Test passed |
Temperature-rise test | |
Requirement temperature-rise test | Increase in temperature ≤ 45 K |
Result | Test passed |
Power-frequency withstand voltage | |
Test voltage setpoint | 2.2 kV |
Result | Test passed |
Mechanical data | |
Open side panel | Yes |
Mechanical strength | |
Result | Test passed |
Attachment on the carrier | |
DIN rail/fixing support | NS 35 |
Test force setpoint | 5 N |
Result | Test passed |
Aging | |
Temperature cycles | 192 |
Needle-flame test | |
Time of exposure | 30 s |
Result | Test passed |
Oscillation/broadband noise | |
Specification | DIN EN 50155 (VDE 0115-200):2018-05 |
Spectrum | Service life test category 2, bogie-mounted |
Frequency | f1 = 5 Hz to f2 = 250 Hz |
ASD level | 6.12 (m/s²)²/Hz |
Acceleration | 3.12g |
Test duration per axis | 5 h |
Test directions | X-, Y- and Z-axis |
Shocks | |
Pulse shape | Half-sine |
Acceleration | 30g |
Shock duration | 18 ms |
Number of shocks per direction | 3 |
Test directions | X-, Y- and Z-axis (pos. and neg.) |
Ambient conditions | |
Ambient temperature (operation) | -60 °C ... 105 °C (max. short-term operating temperature RTI Elec.) |
Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
Ambient temperature (assembly) | -5 °C ... 70 °C |
Ambient temperature (actuation) | -5 °C ... 70 °C |
Permissible humidity (storage/transport) | 30 % ... 70 % |
Connection in acc. with standard | IEC 60947-7-1 |
Mounting type | NS 35/7,5 |
NS 35/15 |
Item number | 3064247 |
Packing unit | 50 pc |
Minimum order quantity | 50 pc |
Sales Key | BE1111 |
Product Key | BE1111 |
GTIN | 4046356289856 |
Weight per Piece (including packing) | 17.085 g |
Weight per Piece (excluding packing) | 17.085 g |
Customs tariff number | 85369010 |
Country of origin | DE |
ECLASS-9.0 | 27141120 |
ECLASS-10.0.1 | 27141120 |
ECLASS-11.0 | 27141120 |
ETIM 8.0 | EC000897 |
UNSPSC 21.0 |
China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
No hazardous substances above threshold values |