AXL F SSDOR4/2 1F
-
Safety module
2702859
Axioline F, Relay module, Functional safety, Signal inputs: 2, Outputs OUT24V_0 and OUT24V_1: 2, Safe relay outputs: 4 (floating), N/O contact, max. 30 V DC, degree of protection: IP20; The product is being prepared for compliance with the Cyber Resilience Act (CRA).
Free download available.
Downloads
Product details
| Dimensional drawing |
|
| Width | 53.6 mm |
| Height | 126.1 mm |
| Depth | 54 mm |
| Note on dimensions | Housing dimensions |
| Note on application | Only for industrial use |
| Note on application | As things stand now, we are preparing the product so that, as of December 11, 2027, it will comply with the requirements of the EU Cyber Resilience Act (CRA) based on the information currently available regarding the CRA. |
| Mounting type | DIN rail mounting |
| Mounting position | any |
| Color (Housing) | yellow (RAL 1018) |
| Material | PBT |
| Flammability rating according to UL 94 | V-0 |
| Axioline F local bus | |
| Connection method | Bus base module |
| Programming data | |
| Input address area | 8 Byte |
| Output address area | 8 Byte |
| Fieldbus data telegram | |
| Required parameter data | 1 Byte |
| Required configuration data | 7 Byte |
| Digital: | |
| Input name | Signal inputs |
| Number of inputs | 2 |
| Input voltage | Power supply from clock outputs UT1 and UT2 |
| Nominal input current at UIN | typ. 3.2 mA |
| Digital: | |
| Output name | Outputs OUT24V_0 and OUT24V_1 |
| Number of outputs | 2 |
| Nominal output voltage | Power supply from U0 or U1 |
| Relay | |
| Number of outputs | 4 (floating) |
| Contact switching type | N/O contact |
| Contact material | AgSnO2 |
| Switching voltage | min. 12 V AC/DC |
| max. 30 V AC/DC | |
| Switching current | min. 3 mA |
| max. 6 A (30 V DC) | |
| Limiting continuous current | 6 A |
| Switching power | min. 60 mW |
| Switching frequency | max. 1 Hz |
| Output fuse | 6 A gL/gG (See “Application examples” section) |
| Mechanical service life | 10x 106 cycles |
| Product type | I/O component |
| Product family | Axioline F |
| Application | Functional safety |
| Type | modular |
| Mounting position | any |
| Operating mode | SafetyBridge |
| Special properties | The product is being prepared for compliance with the Cyber Resilience Act (CRA) |
| Insulation characteristics | |
| Overvoltage category | II (IEC 60664-1) |
| Pollution degree | 2 (IEC 60664-1) |
| Transmission medium | Copper |
| Potentials | |
| Protection | max. 500 mA slow-blow (for UI) |
| max. 6 A gL/gG (For U0 and U1 respectively) | |
| Protective circuit | Polarity reversal protection of the supply voltage; parallel protection against polarity reversal for a limited period of time |
| Surge voltage detection; at 31 V | |
| Undervoltage detection; at 17 V | |
| Surge protection of the supply voltage; electronic (35 V, 0.5 s) | |
| Potentials: Axioline F local bus supply (UBus) | |
| Supply voltage | 5 V DC (via bus base module) |
| Current draw | max. 163 mA (at UBus 5 V DC) |
| typ. 93 mA (at UBus 5 V DC) | |
| Potentials: Supply voltage UI for EDM | |
| Supply voltage | 24 V DC |
| Supply voltage range | 19.2 V DC ... 30.2 V DC (including all tolerances, including ripple) |
| Current draw | max. 30 mA |
| typ. 10 mA (Power supply from UI with 30 V DC, all inputs set) | |
| Potentials: Feed-in U0 and U1 for safe I/O supply | |
| Supply voltage | 24 V DC |
| Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Current draw | max. 6 A |
| typ. 1.6 mA (Power supply from U0 with 30 V DC, all inputs set without load) | |
| Connection technology | |
| Connection name | I/O |
| Note on the connection method | Note the specification in the section Conductor cross-sections, and stripping and insertion lengths. |
| I/O | |
| Connection method | Push-in connection |
| Note on the connection method | Note the specification in the section Conductor cross-sections, and stripping and insertion lengths. |
| Conductor cross-section, rigid | 0.5 mm² ... 1.5 mm² |
| Conductor cross-section, flexible | 0.5 mm² ... 1.5 mm² |
| Conductor cross-section AWG | 20 ... 16 |
| Stripping length | 8 mm |
| Ambient conditions | |
| Ambient temperature (operation) | -35 °C ... 60 °C |
| Degree of protection | IP20 |
| Degree of protection at installation location | min. IP54 |
| Air pressure (operation) | 70 kPa ... 108 kPa |
| Air pressure (storage/transport) | 66 kPa ... 108 kPa |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Mechanical test | |
| Vibration resistance in accordance with EN 60068-2-6/IEC 60068-2-6 | 2g |
| Shock in accordance with EN 60068-2-27/IEC 60068-2-27 | 15g |
| Continuous shock in accordance with EN 60068-2-27/IEC 60068-2-27 | 10g |
| Protection class | III (IEC 61140-1) |
| Air clearances and creepage distances | |
| Air clearances and creepage distances | IEC 60664-1 |
| Safety data: EN ISO 13849 | |
| Performance level (PL) | c (1-channel assignment) |
| e (2-channel assignment) | |
| Item number | 2702859 |
| Packing unit | 1 pc |
| Minimum order quantity | 1 pc |
| Sales key | DN03 |
| Product key | DNA532 |
| GTIN | 4055626363295 |
| Weight per piece (including packing) | 270 g |
| Weight per piece (excluding packing) | 218 g |
| Customs tariff number | 85371098 |
| Country of origin | DE |
ECLASS
| ECLASS-13.0 | 27242604 |
| ECLASS-15.0 | 27242604 |
| ECLASS-15.0 ASSET | 27250101 |
ETIM
| ETIM 10.0 | EC001599 |
UNSPSC
| UNSPSC 21.0 | 32151600 |
| EU RoHS | |
| Fulfills EU RoHS substance requirements | Yes |
| Exemption | 7(a), 7(c)-I |
| China RoHS | |
| Environment friendly use period (EFUP) |
EFUP-50
An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required.
|
| EU REACH SVHC | |
| REACH candidate substance (CAS No.) | Lead (CAS: 7439-92-1) |
| SCIP | 8db25eb2-3768-4936-8194-eb49c94e7f73 |
Compatible products
Frequently searched
PHOENIX CONTACT
586 Fulling Mill Road, Middletown, PA 17057