The safety relay PSR-MC73 is designed to monitor various items of safety equipment, e.g., emergency stop, safety doors, or light grids. Despite its compact overall width of 22.5 mm, the device offers the option of setting release or on delays with high accuracy in the range from 0.2 s to 300 s. In addition, the delay time can be reset using the adjustable retrigger function when the safety function is demanded.
PSR-MC73-5NO-1DO-24DC-SC
-
Safety relays
1015533
Safety relay for emergency stop, safety doors, light grids up to SIL 3, Cat. 4, PL e, 1- or 2-channel operation, cross-circuit detection, can be retriggered, off-/on delay of 0.2 s to 300 s, 5 enabling current paths, US = 24 V DC, plug-in screw terminal block
Free download available.
Downloads
Product details
| Note on application | |
| Note on application | Only for industrial use |
| Product type | Safety relays |
| Product family | PSRcompact |
| Application | Emergency stop |
| Safety door | |
| Light grid | |
| Control | 1 and 2 channel |
| Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
| Insulation characteristics | |
| Overvoltage category | III |
| Degree of pollution | 2 |
| Times | |
| Typical response time | < 50 ms (automatic start) |
| < 50 ms (manual, monitored start) | |
| Typ. starting time with Us | 500 ms (with Us when controlled via A1) |
| Typical release time | < 25 ms (when controlled via S12 and S22 (only for undelayed contacts)) |
| < 10 ms (when controlled via A1; applicative deactivation via A1/A2 is not permitted) | |
| Delay time range | 0.2 s ... 300 s ±5 % (can be set for 47/48, 57/58) |
| Restart time | < 1 s (Boot time) |
| Recovery time | 500 ms (following demand of the safety function) |
| 100 ms (Availability time after activating the sensor circuit during manual start) | |
| Start pulse length | min. 500 ms (manual start) |
| Maximum power dissipation for nominal condition | 9.91 W (at US = 30 V, IL² = 144 A²) |
| Nominal operating mode | 100% operating factor |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage/insulation | See data sheet, section “Insulation coordination”. |
| Supply | |
| Designation | A1/A2 |
| Rated control circuit supply voltage US | 24 V DC -20 % / +25 % |
| Rated control supply current IS | typ. 80 mA |
| Power consumption at US | typ. 1.92 W |
| Inrush current | typ. 28 A (Δt = 30 µs at Us) |
| Filter time | 1 ms (For the logic. At A1 in the event of voltage dips at Us ) |
| Protective circuit | Serial protection against polarity reversal |
| Suppressor diode | |
| Digital: Sensor circuit (S12, S22) | |
| Description of the input | safety-related sensor inputs |
| Number of inputs | 2 |
| Input voltage range "0" signal | 0 V DC ... 5 V DC |
| Input voltage range "1" signal | 11 V DC ... 30 V DC |
| Input current range "0" signal | 0 mA ... 2 mA |
| Inrush current | < 11 mA (typ. with US) |
| Filter time | max. 3 ms (Test pulse width of low test pulses) |
| min. 21 ms (Test pulse rate for low test pulse) | |
| Concurrence | ∞ |
| Limit frequency | min. 0 Hz |
| max. 1 Hz | |
| Max. permissible overall conductor resistance | 150 Ω |
| Protective circuit | Varistor |
| Current consumption | < 4.5 mA (typ. with US) |
| Digital: Start circuit (S34) | |
| Description of the input | non-safety-related |
| Number of inputs | 1 |
| Input voltage range "0" signal | 0 V DC ... 5 V DC |
| Input voltage range "1" signal | 11 V DC ... 30 V DC |
| Input current range "0" signal | 0 mA ... 2 mA |
| Inrush current | < 8.6 mA (typ. with US) |
| Filter time | max. 1 ms (Test pulse width of low test pulses) |
| min. 21 ms (Test pulse rate for low test pulse) | |
| Limit frequency | min. 0 Hz |
| max. 1 Hz | |
| Max. permissible overall conductor resistance | 150 Ω |
| Protective circuit | Varistor |
| Current consumption | < 3.2 mA (typ. with US) |
| Relay: Enabling current paths (13/14, 23/24/34, 47/48, 57/58) | |
| Output description | 2 N/O contacts each in series, safety-related, floating |
| Number of outputs | 3 (undelayed: 13/14, 23/24/34) |
| 2 (delayed: 47/48, 57/58) | |
| Contact switching type | 5 enabling current paths |
| Contact material | AgCuNi +0.2 µm ... 0.4 µm Au / AgSnO2 +0.2 µm Au |
| Switching voltage | min. 12 V AC/DC |
| max. 250 V AC/DC | |
| Switching power | min. 60 mW |
| Inrush current | min. 5 mA |
| max. 6 A | |
| Switching capacity | 4 A (24 V (DC13)) |
| 3 A (230 V (AC 15)) | |
| Limiting continuous current | 6 A |
| Sq. Total current | 144 A2 (observe derating) |
| Switching frequency | 0.1 Hz (depending on the set delay time) |
| Mechanical service life | 10x 106 cycles |
| Output fuse | 6 A gL/gG |
| 4 A gL/gG (for low-demand applications) | |
| Signal: M1 | |
| Output description | PNP |
| non-safety-related | |
| Number of outputs | 1 |
| Voltage | approx. 23 V DC (US - 1 V) |
| Current | max. 100 mA |
| Maximum inrush current | 500 mA (Δt = 100 ms at Us) |
| Ohmic load | min. 192 Ω (max. 100 mA) |
| Switching frequency | 0.1 Hz (depending on the set delay time) |
| Protective circuit | Suppressor diode |
| Short-circuit protection | Yes |
| Discharging circuit | no |
| Clock: S11, S21 | |
| Output description | PNP |
| non-safety-related | |
| Number of outputs | 2 |
| Voltage | corresponds to US |
| Current | max. 100 mA |
| Maximum inrush current | 500 mA (Δt = 100 ms at Us) |
| Protective circuit | Suppressor diode |
| Short-circuit protection | Yes |
| Discharging circuit | no |
| Connection technology | |
| pluggable | yes |
| Conductor connection | |
| Connection method | Screw connection |
| Conductor cross-section rigid | 0.2 mm² ... 2.5 mm² |
| Conductor cross-section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross-section AWG | 24 ... 12 |
| Stripping length | 7 mm |
| Screw thread | M3 |
| Tightening torque | 0.5 Nm ... 0.6 Nm |
| Status display | 4 x LED (green, yellow, red) |
| Operating voltage display | 1 x LED (green, yellow, red) |
| Width | 22.5 mm |
| Height | 112.7 mm |
| Depth | 111.7 mm |
| Color (Housing) | yellow (RAL 1018) |
| Housing material | PA |
| Safety data | |
| Stop category (EN 60204-1) | 0 (Undelayed contacts) |
| Stop category | 1 (delayed contacts) |
| Safety data: EN ISO 13849 | |
| Performance level (PL) | e (4 A DC13; 3 A AC15; 8760 switching cycles/year) |
| Safety data: IEC 61508 - High demand | |
| Safety Integrity Level (SIL) | 3 |
| Safety data: IEC 61508 - Low demand | |
| Safety Integrity Level (SIL) | 3 |
| Safety data: EN IEC 62061 | |
| Safety Integrity Level (SIL) | 3 |
| Ambient conditions | |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Ambient temperature (operation) | -35 °C ... 55 °C (observe derating) |
| -35 °C ... 60 °C (mounted in the horizontal mounting position with ≥ 10 mm spacing) | |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Maximum altitude | ≤ 2000 m (Above sea level) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Shock | 10g (operation), 15g (transport) |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g |
| Mounting type | DIN rail mounting |
| Assembly note | See derating curve |
| Mounting position | vertical or horizontal |
| Item number | 1015533 |
| Packing unit | 1 pc |
| Minimum order quantity | 1 pc |
| Sales key | DN01 |
| Product key | DNA181 |
| GTIN | 4055626496740 |
| Weight per piece (including packing) | 245.4 g |
| Weight per piece (excluding packing) | 223.1 g |
| Customs tariff number | 85371098 |
| Country of origin | DE |
ECLASS
| ECLASS-13.0 | 27371819 |
| ECLASS-15.0 | 27371819 |
ETIM
| ETIM 10.0 | EC001449 |
UNSPSC
| UNSPSC 21.0 | 39122200 |
| EU RoHS | |
| Fulfills EU RoHS substance requirements | Yes |
| Exemption | 7(a), 7(c)-I |
| China RoHS | |
| Environment friendly use period (EFUP) |
EFUP-50
An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required.
|
| EU REACH SVHC | |
| REACH candidate substance (CAS No.) | Lead (CAS: 7439-92-1) |
| 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol (CAS: 79-94-7) | |
| SCIP | 3bb6380a-3506-4e07-921f-eefa21a54032 |
Compatible products
Your advantages
Up to Cat. 4/PL e in accordance with EN ISO 13849-1, SIL 3 in accordance with EN IEC 62061
Low housing width of only 22.5mm
1 or 2-channel control
2 enabling current paths (adjustable, retriggerable release or on delay), 1 digital signal output
Adjustable delay time from 0.2 s ... 300 s
PHOENIX CONTACT
586 Fulling Mill Road, Middletown, PA 17057