Sensor/actuator cable, 2-position, Variable cable type, shielded, Plug straight M12 SPEEDCON, coding: A, on free cable end, cable length: Free input (0.2 ... 40.0 m), For railway applications


Product Details




General Further products with variable cable type and variable cable length can be found in the accessories section

Product type Sensor/actuator cable
Number of positions 2
Application Railway applications
No. of cable outlets 1
Shielded yes
Coding A - standard
Insulation characteristics
Overvoltage category II
Degree of pollution 3

Color Handle area black
Flammability rating according to UL 94 V0
Material of grip body PA 6.6
Contact material CuSn
Contact surface material Ni/Au
Contact carrier material PA 6.6
Cable gland material Zinc die-cast, nickel-plated
Standards/regulations PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)

Contact resistance ≤ 5 mΩ
Insulation resistance ≥ 100 MΩ
Nominal voltage UN 250 V AC
250 V DC
Nominal current IN 4 A
Protective circuit unwired

Conductor connection
Tightening torque 0.4 NmM12 connector

Insertion/withdrawal cycles ≥ 100
Header 1
Head design Plug
Head cable outlet straight
Head thread type M12
Head locking type SPEEDCON
Coding A
Head 2
Head design free cable end

Status display No
Status display present No

Cable length Free input (0.2 ... 40.0 m)
Shielded black RADOX® [28R]
Dimensional drawing
Shielded yes
Cable weight 42 kg/km
Cable type Shielded black RADOX®
Cable type (abbreviation) 28R
External cable diameter 4.8 mm ±0.3 mm
Outer sheath, material PE-X
External sheath, color black
Conductor material Tin-plated Cu litz wires
Conductor structure signal line 19x 0.18 mm
AWG signal line 20
Conductor cross section 2x 0.5 mm²
Material wire insulation PE-X
Wire diameter incl. insulation 1.4 mm
Single wire, color White 1, white 2
Overall twist 2 wires, twisted
Shielding Tinned copper braided shield
Nominal voltage, cable 600 V AC (Core-ground, U0)
1000 V AC (Core-ground, U)
≤ 720 V AC (core-ground)
≤ 1200 V AC (Core-ground, Um)
≤ 900 V DC (Core-ground, V0)
≤ 1500 V DC (core-core)
Test voltage, cable 3500 V AC (50 Hz, 5 min.)
8400 V DC (50 Hz, 5 min.)
Conductor resistance ≤ 40.1 Ω/km
Minimum bending radius, fixed installation 3 x D
Minimum bending radius, flexible installation 4 x D
Fire protection in rail vehicles BS 6853 (Category Ia, Ib, II)
GM/RT 2130 (Category Ia, Ib, II)
EN 45545 (Risk level HL1 - HL3)
DIN 5510 (Fire protection level 1, 2, 3, 4)
NF F16-101 (Category A1, A2, B)
NF F16-101 (Class C/F0)
NFPA 130
UNI CEI 11170 (Risk level LR1 - LR4)
Halogen-free According to EN 50267-2-1
Resistance to oil according to IRM 902, 72 h at 100 °C
Concentration of fumes BS 6853 D.8.7
EN 61034-2
UL 1685, 12 (FT4)
Fume toxicity BS 6853 B.1
EN 50305, 9.2
Fume corrosiveness EN 50267-2-2
Flame resistance EN 60332-1-2
EN 50266
EN 50305, 9.1.2
NF C32-070, 2.1
NF C32-070, 2.2
UL 1685, 12 (FT4)
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Other resistance Resistance to fuels according to IRM 903, 168 h at 70 °C
Ambient temperature (operation) -25 °C ... 90 °C (Cable, flexible installation)
-50 °C ... 120 °C (cable, fixed installation)
RADOX® black shielded 0.75 mm² [29R]
Dimensional drawing
Shielded yes
Cable weight 48 kg/km
Cable type RADOX® black shielded 0.75 mm²
Cable type (abbreviation) 29R
External cable diameter 5 mm ±0.3 mm
Outer sheath, material PE-X
External sheath, color black
Conductor material Tin-plated Cu litz wires
Conductor structure signal line 19x 0.22 mm
AWG signal line 18
Conductor cross section 2x 0.75 mm²
Material wire insulation PE-X
Wire diameter incl. insulation 1.63 mm
Single wire, color White 1, white 2
Overall twist 2 wires, twisted
Shielding Tinned copper braided shield
Nominal voltage, cable 600 V AC (Core-ground, U0)
1000 V AC (Core-ground, U)
≤ 720 V AC (core-ground)
≤ 1200 V AC (Core-ground, Um)
≤ 900 V DC (Core-ground, V0)
≤ 1500 V DC (core-core)
Test voltage, cable 3500 V AC (50 Hz, 5 min.)
8400 V DC (50 Hz, 5 min.)
Conductor resistance ≤ 26.7 Ω/km
Minimum bending radius, fixed installation 3 x D
Minimum bending radius, flexible installation 4 x D
Fire protection in rail vehicles BS 6853 (Category Ia, Ib, II)
GM/RT 2130 (Category Ia, Ib, II)
EN 45545 (Risk level HL1 - HL3)
DIN 5510 (Fire protection level 1, 2, 3, 4)
NF F16-101 (Category A1, A2, B)
NF F16-101 (Class C/F0)
NFPA 130
UNI CEI 11170 (Risk level LR1 - LR4)
Halogen-free According to EN 50267-2-1
Resistance to oil according to IRM 902, 72 h at 100 °C
Concentration of fumes BS 6853 D.8.7
EN 61034-2
UL 1685, 12 (FT4)
Fume toxicity BS 6853 B.1
EN 50305, 9.2
Fume corrosiveness EN 50267-2-2
Flame resistance EN 60332-1-2
EN 50266
EN 50305, 9.1.2
NF C32-070, 2.1
NF C32-070, 2.2
UL 1685, 12 (FT4)
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Other resistance Resistance to fuels according to IRM 903, 168 h at 70 °C
Ambient temperature (operation) -25 °C ... 90 °C (Cable, flexible installation)
-50 °C ... 120 °C (cable, fixed installation)
RADOX® black shielded 1.0 mm² [30R]
Dimensional drawing
Shielded yes
Cable weight 60 kg/km
Cable type RADOX® black shielded 1.0 mm²
Cable type (abbreviation) 30R
External cable diameter 5.6 mm ±0.3 mm
Outer sheath, material PE-X
External sheath, color black
Conductor material Tin-plated Cu litz wires
Conductor structure signal line 19x 0.25 mm
AWG signal line 17
Conductor cross section 2x 1 mm²
Material wire insulation PE-X
Wire diameter incl. insulation 1.75 mm
Single wire, color White 1, white 2
Overall twist 2 wires, twisted
Shielding Tinned copper braided shield
Nominal voltage, cable 600 V AC (Core-ground, U0)
1000 V AC (Core-ground, U)
≤ 720 V AC (core-ground)
≤ 1200 V AC (Core-ground, Um)
≤ 900 V DC (Core-ground, V0)
≤ 1500 V DC (core-core)
Test voltage, cable 3500 V AC (50 Hz, 5 min.)
8400 V DC (50 Hz, 5 min.)
Conductor resistance 20 Ω/km
Minimum bending radius, fixed installation 3 x D
Minimum bending radius, flexible installation 4 x D
Fire protection in rail vehicles BS 6853 (Category Ia, Ib, II)
GM/RT 2130 (Category Ia, Ib, II)
EN 45545 (Risk level HL1 - HL3)
DIN 5510 (Fire protection level 1, 2, 3, 4)
NF F16-101 (Category A1, A2, B)
NF F16-101 (Class C/F0)
NFPA 130
UNI CEI 11170 (Risk level LR1 - LR4)
Halogen-free According to EN 50267-2-1
Resistance to oil according to IRM 902, 72 h at 100 °C
Concentration of fumes BS 6853 D.8.7
EN 61034-2
UL 1685, 12 (FT4)
Fume toxicity BS 6853 B.1
EN 50305, 9.2
Fume corrosiveness EN 50267-2-2
Flame resistance EN 60332-1-2
EN 50266
EN 50305, 9.1.2
NF C32-070, 2.1
NF C32-070, 2.2
UL 1685, 12 (FT4)
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Other resistance Resistance to fuels according to IRM 903, 168 h at 70 °C
Ambient temperature (operation) -25 °C ... 90 °C (Cable, flexible installation)
-50 °C ... 120 °C (cable, fixed installation)
Note This item is a sensor/actuator cable with a freely selectable cable type. The technical data for all possible cable types is listed in the table below.

Degree of protection IP65
Ambient temperature (operation) -40 °C ... 85 °C (Plug / socket)

Testing
Standards/regulations PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)
M12
Standards/specifications IEC 61076-2-101
Standards/specifications EN 50155

Item number 1412159
Packing unit 1 pc
Minimum order quantity 1 pc
Sales Key BF1
Product Key BF1CIA
GTIN 4046356993500
Customs tariff number 85444290
Country of origin PL


ECLASS

ECLASS-9.0 27060311
ECLASS-10.0.1 27060311
ECLASS-11.0 27060311

ETIM

ETIM 8.0 EC001855

UNSPSC

UNSPSC 21.0

EAC

Approval ID: RU C-DE.BL08.B.00286

REACh SVHC Dechlorane Plus
China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Compatible Products


  1. Sensor/actuator cable SAC-2P-MR SCO RAIL/.../... - 1412160

  2. Torque screwdriver TSD 04 SAC - 1208429

  3. Sensor/actuator cable SAC-2P-FS SCO RAIL/.../... - 1412157

  4. Torque screwdriver TSD-M 1,2NM - 1212224

  5. Adapter insert TSD-M SAC-BIT ADAPTER - 1212600

  6. Tool SAC BIT M12-D15 - 1208432

  7. Sealing cap PROT-M12 FS-PA-CHAIN - 1430873

  8. Locking clip SAC-M12-EXCLIP-M - 1558988

  9. Marker pen B-STIFT - 1051993

  10. Conductor marker carrier PATG HF 3/18 - 1014059

  11. Conductor marker carrier PATG HF 3/23 - 1014060

  12. Conductor marker carrier PATG HF 3/30 - 1014061

  13. Conductor marker carrier PATG HF 4/18 - 1014065

  14. Conductor marker carrier PATG HF 4/23 - 1014066

  15. Conductor marker carrier PATG HF 4/30 - 1014067

  16. Cable marker carrier KMK HP (25X6) - 0830720

  17. Cable marker carrier KMK HP (29X8) - 0830721

  18. Cable marker WMTB HF (40X12)R YE - 0830408

  19. Cable marker WMTB HF (55X15)R YE - 0830410

  20. Cable marker WMTB HF (55X25)R YE - 0830412

  21. Shrink sleeve WMS-2 HF 6,4 (60X10)RL YE - 0801025

  22. Shrink sleeve WMS-2 HF 6,4 (EX10)RL YE - 0833244

  23. Shrink sleeve WMS-2 HF 9,5 (60X16)RL YE - 0801029

  24. Shrink sleeve WMS-2 HF 9,5 (EX16)RL YE - 0833245

  25. Wire marking UCT-WMCO 5,4 (23X8) - 0832105

  26. Wire marking UCT-WMCO 6,1 (23X8) - 0832106

  27. Wire marking UCT-WMCO 6,8 (23X8) - 0832107

  28. Wire marking UCT-WMCO 7,5 (23X8) - 0832108

  29. Cable marker WMTB-AL (40X15) - 0830524

  30. Cable marker WMTB-AL (60X15) - 0830525

  31. Cable marker LS-WMTB-AL (40X15) - 0831501

  32. Cable marker LS-WMTB-AL (40X15) BK - 0831509

  33. Cable marker LS-WMTB-AL (60X15) - 0831502

  34. Cable marker LS-WMTB-AL (60X15) BK - 0831510

  35. Cable marker LS-WMTB-AL (100X15) - 0831503

  36. Cable marker LS-WMTB-AL (100X15) BK - 0831511

  37. Cable-cutting tool CUTFOX 12 - 1212128

  38. Diagonal cutter CUTFOX-S VDE - 1212207

  39. Diagonal cutter MICROFOX-SP-1 - 1212487

  40. Stripping tool WIREFOX 4 - 1212156

  41. Stripping tool WIREFOX-E 4 - 1212704

  42. Stripping tool WIREFOX 10 - 1212150

  43. Connector SACC-MS-4QO-0,75 SH SCO - 1413993

  44. Connector SACC-FS-4QO-0,75 SH SCO - 1413994

  45. Connector SACC-M12MS-4PL SH - 1424666

  46. Connector SACC-M12MR-4PL SH - 1424667

  47. Connector SACC-M12FS-4PL SH - 1424668

  48. Connector SACC-M12FR-4PL SH - 1424669

  49. Connector SACC-M12MS-5CT-CM SH - 1422850

  50. Connector SACC-M12MR-5CT-CM SH - 1422851

  51. Connector SACC-M12FS-5CT-CM SH - 1422852

  52. Connector SACC-M12FR-5CT-CM SH - 1422853

  53. Connector SACC-PO12MS-5CT-CM SH - 1021815

  54. Connector SACC-PO12MR-5CT-CM SH - 1021816


Your advantages

Easy and safe: 100% electrically tested plug-in components
Securely locked by special vibration brake
Resistant to temperature influences – tested for an extended temperature range and for resistance to temperature shocks
Reliable signal transmission – 360° shielding in environments with electromagnetic interference