Router - CLOUD CLIENT 2002T-4G EU
1234355

Industrial VPN gateway for mGuard Secure Cloud, IPsec communication via 4G (LTE), EU device, 2-port switch, antenna connections: 2 SMA cellular communication, 4 DI, 2 DO


Product Details




MTTF 384 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
180 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
64 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)

Electrical isolation VCC // LTE // Ethernet // PE
Mains type Cellular communication
Supply
Supply voltage range 10 V DC ... 30 V DC (Via pluggable Push-in terminal block)
Typical current consumption < 180 mA (24 V DC)
≤ 3 mA (With activated energy-saving mode)
Max. current consumption 1.5 A
Connection method Push-in spring connection
Function
Management Web-based management
SNMPv1/v2/v3
Data storage Micro SDHC card

Digital
Description of the input Digital input
Number of inputs 4
Voltage input signal 10 V DC ... 30 V DC
Switching level "0" signal < 8 V DC
Switching level "1" signal 10 V DC ... 30 V DC

Signal
Output name Digital output
Number of outputs 2
Voltage output signal 10 V DC ... 30 V DC (depending on the operating voltage)
Current output signal ≤ 50 mA (Not short-circuit proof)

Supply
Connection method Push-in spring connection
Conductor cross section flexible, with ferrule without plastic sleeve 0.25 mm² ... 1.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve 0.25 mm² ... 0.75 mm²
Conductor cross section, flexible 0.14 mm² ... 1.50 mm²
Conductor cross section, rigid 0.14 mm² ... 1.50 mm²
Conductor cross section AWG 26 ... 16
Stripping length 9 mm

Data: Ethernet interface, 10/100Base-T(X) in accordance with IEEE 802.3
Serial transmission speed 10/100 Mbps, auto negotiation
Connection method RJ45 jack, shielded
No. of channels 2
Transmission length 100 m (shielded twisted pair)
Protocols supported TCP/IP, UDP/IP, HTTP(S), (S)FTP, TFTP, SCEP, RADIUS, IPsec
Network Discovery: LLDP, CDP, FDP, SONMP, EDP, IRDP
Auxiliary protocols ARP, DHCP, DNS, DynDNS, PING (ICMP), SMTP(S), NTP, SSL/TLS, STARTTLS, SMS
Wireless
Interface description GSM / GPRS / EDGE / UMTS / HSPA / LTE (FDD)
Frequency range 800 MHz (LTE B20)
850 MHz (LTE B5)
900 MHz (LTE B8)
1800 MHz (LTE B3)
2100 MHz (LTE B1)
2600 MHz (LTE B7)
850 MHz (UMTS/HSPA B5)
900 MHz (UMTS/HSPA B8)
1900 MHz (UMTS/HSPA B2)
2100 MHz (UMTS/HSPA B1)
850 MHz (2 W (EGSM))
900 MHz (2 W (EGSM))
1800 MHz (1 W (EGSM))
1900 MHz (1 W (EGSM))
Data rate ≤ 150 Mbps (LTE (DL))
≤ 50 Mbps (LTE (UL))
Antenna 50 Ω impedance SMA antenna socket
Antenna connection method SMA (female)
SIM Interface Micro SIM (3FF)
eSIM (several profiles)
GPRS Class 12, Class B
CS1 ... CS4
EDGE Multislot Class 12
UMTS HSPA 3GPP R8
LTE CAT4
Country support Europe

Dimensional drawing
Width 45 mm
Height 130 mm
Depth 130 mm

Color gray
Housing material Polycarbonate

Ambient conditions
Degree of protection IP20
Ambient temperature (operation) -40 °C ... 70 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Altitude ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
Permissible humidity (operation) 10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing)

CE
Certificate CE-compliant

Electromagnetic compatibility Conformance with RED Directive 2014/53/EU
Noise immunity EN 61000-6-2
Electrostatic discharge
Standards/regulations EN 61000-4-2
Electrostatic discharge
Contact discharge ± 6 kV (Test Level 3)
Discharge in air ± 8 kV (Test Level 3)
Comments Criterion B
Electromagnetic HF field
Standards/regulations EN 61000-4-3
Electromagnetic HF field
Frequency range 80 MHz ... 3 GHz (Test Level 3)
Field intensity 10 V/m
Comments Criterion A
Fast transients (burst)
Standards/regulations EN 61000-4-4
Fast transients (burst)
Input ± 2 kV (Test Level 3)
Signal ± 2 kV (Ethernet)
Comments Criterion B
Surge current load (surge)
Standards/regulations EN 61000-4-5
Surge current load (surge)
Input ± 0.5 kV (symmetrical)
± 1 kV (asymmetrical)
Signal ± 1 kV (Data line, asymmetrical)
Comments Criterion B
Conducted interference
Standards/regulations EN 61000-4-6
Conducted interference
Frequency range 0.15 MHz ... 80 MHz
Comments Criterion A
Voltage 10 V
Emitted interference
Radio interference voltage in acc. with EN 55011 Class B, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011 Class B, area of application: Industry and residential
Criterion A Normal operating behavior within the specified limits.
Criterion B Temporary impairment to operational behavior that is corrected by the device itself.

Mounting type DIN rail mounting

Order Key 1234355
Packing unit 1 pc
Minimum order quantity 1 pc
Sales Key DNC
Product Key DNC422
GTIN 4063151338350
Customs tariff number 85176200
Country of origin DE


ECLASS

ECLASS-9.0 19170103
ECLASS-10.0.1 19170502
ECLASS-11.0 19170502

China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Your advantages

Industrial 4G cellular router (LTE)
Fallback to 3G (UMTS/HSPA) and 2G (GPRS/EDGE)
Virtual dedicated line to connect networks via cellular network
Configuration via web-based management or microSD card
Two local Ethernet connections
Switchable energy-saving mode
Integrated logbook
Extended temperature range, -40 ºC ... +70 ºC
Micro SIM and eSIM for maximum network availability
Four digital inputs
Two digital outputs