I/O component - AXL F AO4 XC 1H
2702153

Axioline F XC, Analog output module, Analog outputs: 4, 0 V ... 5 V, -5 V ... 5 V, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, connection technology: 2-conductor, transmission speed in the local bus: 100 Mbps, Extreme conditions version, degree of protection: IP20, including bus base module and Axioline F connectors


Product Details


The module is designed for use within an Axioline F station.It is used to output analog voltage and current signals.



Dimensional drawing
Width 35 mm
Height 126.1 mm
Depth 54 mm
Note on dimensions The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).

Color traffic grey A RAL 7042

Axioline F local bus
Number of interfaces 2
Connection method Bus base module
Transmission speed 100 Mbps

Analog
Output name Analog outputs
Connection method Push-in connection
Connection technology 2-conductor
Note regarding the connection technology shielded, twisted pair
Number of outputs 4
D/A converter resolution 16 bit
Protective circuit Short-circuit and overload protection; electronic
Transient protection; Suppressor diode
Data formats IB IL, S7-compatible
Representation of output values 16 bits (15 bits + sign)
Process data update 140 µs
Current output signal 0 mA ... 20 mA
4 mA ... 20 mA
Load/output load current output ≤ 500 Ω
Voltage output signal 0 V ... 5 V
-5 V ... 5 V
0 V ... 10 V
-10 V ... 10 V
Load/output load voltage output ≥ 1 kΩ
Precision typ. 0.1 % (of output range final value)

Type modular
Axioline
Mounting position any (no temperature derating)
Scope of delivery including bus base module and Axioline F connectors
Insulation characteristics
Overvoltage category II (IEC 60664-1, EN 60664-1)
Pollution degree 2 (IEC 60664-1, EN 60664-1)

Potentials: Axioline F local bus supply (UBus)
Supply voltage 5 V DC (via bus base module)
Current draw max. 150 mA
typ. 120 mA
Power consumption max. 0.75 W
typ. 0.6 W
Potentials: Supply for analog modules (UA)
Supply voltage 24 V DC
Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current draw max. 125 mA (4 current channels, 24 mA output, 500 Ω load)
typ. 60 mA (4 voltage channels, 10 V output)
max. 85 mA (4 voltage channels, 10 V output)
max. 110 mA (4 current channels, 20 mA output, 500 Ω load)
Power consumption max. 3 W
Protective circuit Surge protection; electronic (35 V, 0.5 s)
Reverse polarity protection; Polarity protection diode
Transient protection; Suppressor diode

Connection technology
Connection name Axioline F connector
Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor connection
Connection method Push-in connection
Conductor cross section solid 0.2 mm² ... 1.5 mm²
Conductor cross section flexible 0.2 mm² ... 1.5 mm²
Conductor cross section AWG 24 ... 16
Stripping length 8 mm
Axioline F connector
Connection method Push-in connection
Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section, rigid 0.2 mm² ... 1.5 mm²
Conductor cross section, flexible 0.2 mm² ... 1.5 mm²
Conductor cross section AWG 24 ... 16
Stripping length 8 mm

Ambient temperature (operation) -25 °C ... 60 °C (Standard, applications with UL approval, use in zone 2 potentially explosive area)
-40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
Degree of protection IP20
Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Permissible humidity (operation) 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)

Protection class III (IEC 61140, EN 61140, VDE 0140-1)

Conformity/Approvals
ATEX  II 3 G Ex ec IIC T4 Gc
EU-type examination certificate UL 20 ATEX 2241X
IECEx Ex ec IIC T4 Gc
IECEx certificate IECEx ULD 20.0026X
UL, USA / Canada cULus
Class I, Zone 2, AEx ec IIC T4, Ex ec IIC T4 Gc X
Class I, Div. 2, Groups A, B, C, D T4

Mounting type DIN rail
Mounting position any (no temperature derating)

Order Key 2702153
Packing unit 1 pc
Minimum order quantity 1 pc
Sales Key CNI
Catalog Page Page 85 (C-6-2019)
GTIN 4046356991315
Weight per Piece (including packing) 199,2 GRM
Weight per Piece (excluding packing) 199,0 GRM
Customs tariff number 85389091
Country of origin DE


ECLASS

ECLASS-9.0 27242601
ECLASS-10.0.1 27242601
ECLASS-11.0 27242601

ETIM

ETIM 6.0 EC001596

UNSPSC

UNSPSC 19.0 32151602
UNSPSC 20.0 32151602
UNSPSC 21.0 32151602

DNV GL

LR

KR

NK

BV

PRS

UL Listed

cUL Listed

RINA

IECEx

ATEX

cULus Listed


REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Your advantages

4 analog output channels for the connection of either voltage or current signals
Bipolar voltage outputs, unipolar current outputs
Connection of actuators in 2-conductor technology
Voltage ranges: 0 V ... 10 V, ±10 V, 0 V ... 5 V, ±5 V
Current ranges: 0 mA ... 20 mA, 4 mA ... 20 mA
Short-circuit-proof outputs
No derating in all ranges
Short signal rise times
Driving of high loads
Device rating plate stored
Can be used under extreme ambient conditions
Extended temperature range of -40 °C ... +70 °C (see “Tested successfully: use under extreme ambient conditions” in the data sheet)
Partially coated PCBs