Network cable - NBC-FSD SCO RAIL/.../...
1412181

Network cable, PROFINET CAT5 (100 Mbps), Ethernet CAT5 (100 Mbps), 4-position, Variable cable type, shielded, free cable end, on Socket straight M12 SPEEDCON / IP65, coding: D, cable length: Free input (0.2 ... 40.0 m), For railway applications


Product Details




General Further products with variable cable type and variable cable length can be found in the accessories section

Product type Data cable preassembled
Number of positions 4
Application Railway applications
No. of cable outlets 1
Shielded yes
Coding D - data
Insulation characteristics
Overvoltage category II
Degree of pollution 3

Bus system PROFINET
Ethernet
Signal type/category PROFINET CAT5 (IEC 11801), 100 Mbps
Ethernet CAT5 (IEC 11801), 100 Mbps

Status display No
Status display present No

Nominal voltage UN 48 V AC
60 V DC
Nominal current IN 4 A
Transmission medium Copper

Color Handle area black
Flammability rating according to UL 94 V0

Header 1
Type free cable end
Head 2
Type Socket straight M12 SPEEDCON / IP65
Number of positions 4
Coding type D (Data)
Shielded yes
Handle color black
Material CuSn (Contact)
Ni/Au (Contact surface)
PA 6.6 (Contact carriers)
PA 6.6 (Grip)
Zinc die-cast, nickel-plated (Screw connection)
NBR (Seal)
Standards/regulations PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)
Insertion/withdrawal cycles ≥ 100
Contact resistance ≤ 5 mΩ
Insulation resistance ≥ 100 MΩ
Tightening torque 0.4 Nm
Ambient temperature (operation) -40 °C ... 85 °C

Cable length Free input (0.2 ... 40.0 m)
PROFINET RADOX® railway application CAT5 [937]
Dimensional drawing
Shielded yes
Cable weight 70 kg/km
Cable type PROFINET RADOX® railway application CAT5
Cable type (abbreviation) 937
Signal type/category PROFINET CAT5 (IEC 11801), 100 Mbps
EtherCAT® CAT5 (IEC 11801), 100 Mbps
Cable structure 1x4xAWG22/7; SF/TQ
External cable diameter 6.6 mm ±0.4 mm
Outer sheath, material PE-X
External sheath, color black RAL 9005
Thickness, outer sheath approx. 1 mm
Conductor material silver-plated Cu litz wires
Conductor structure signal line 7x 0.25 mm
AWG signal line 22
Conductor cross section 4x 0.34 mm²
Material wire insulation Foamed PE
Wire diameter incl. insulation approx. 1.5 mm
Single wire, color white-blue, orange-yellow
Overall twist Star quad
Shielding Plastic-coated aluminum foil, tinned copper braided shield
Nominal voltage, cable 300 V AC
Test voltage, cable 2000 V AC (50 Hz, 5 minutes)
Conductor resistance ≤ 54.4 Ω/km
Coupling resistance 200.00 mΩ/m (f ≤ 30 MHz)
Wave impedance 100 Ω ±5 Ω (f = 100 MHz)
Working capacitance ≤ 65 pF (core-core)
≤ 100 pF (core-shield)
Signal speed 75 c
Minimum bending radius, fixed installation 6 x D
Damping 2 dB (with 1 MHz)
4.4 dB (at 4 МHz)
7.4 dB (at 10 MHz)
14 dB (at 31.5 МHz)
20 dB (at 62.5 МHz)
26 dB (at 100 MHz)
Remote crosstalk attenuation (FEXT) 78 dB (with 1 MHz)
77 dB (at 4 МHz)
70 dB (at 10 MHz)
65 dB (at 31.5 МHz)
56 dB (at 62.5 МHz)
48 dB (at 100 MHz)
Near end crosstalk attenuation (NEXT) 73 dB (with 1 MHz)
70 dB (at 4 МHz)
65 dB (at 10 MHz)
57 dB (at 31.5 МHz)
52 dB (at 62.5 МHz)
48 dB (at 100 MHz)
Return loss (RL) 25 dB (at 4 МHz)
30 dB (at 10 MHz)
30 dB (at 31.5 МHz)
30 dB (at 62.5 МHz)
28 dB (at 100 MHz)
Shield attenuation 40 dB (30 MHz ≤ f ≤ 100 MHz)
Fire protection in rail vehicles BS 6853 (Category Ia, Ib, II)
GM/RT 2130 (Category Ia, Ib, II)
EN 45545 (Risk level HL1 - HL3)
DIN 5510 (Fire protection level 1, 2, 3, 4)
NF F16-101 (Category A1, A2, B)
NF F16-101 (Class C/F0)
NFPA 130
UNI CEI 11170 (Risk level LR1 - LR4)
Halogen-free According to EN 50267-2-1
Resistance to oil according to IRM 902, 72 h at 100 °C
Concentration of fumes BS 6853 D.8.7
EN 61034-2
UL 1685, 12 (FT4)
Fume toxicity BS 6853 B.1
EN 50305, 9.2
Fume corrosiveness EN 50267-2-2
Flame resistance EN 60332-1-2
EN 50266
EN 60332-3-25
NF C32-070, 2.1
NF C32-070, 2.2
UL 1685, 12 (FT4)
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Other resistance Resistance to fuels according to IRM 903, 168 h at 70 °C
Ambient temperature (operation) -40 °C ... 90 °C (Cable, flexible installation)
-50 °C ... 90 °C (cable, fixed installation)
PROFINET RADOX® railway application CAT5 reinforced [936]
Dimensional drawing
Shielded yes
Cable weight 81 g/m
Cable type PROFINET RADOX® railway application CAT5 reinforced
Cable type (abbreviation) 936
Signal type/category PROFINET CAT5 (IEC 11801), 100 Mbps
Cable structure 1x4xAWG22/7; SF/TQ
External cable diameter 7.25 mm ±0.3 mm
Outer sheath, material PE-X
External sheath, color black RAL 9005
Thickness, outer sheath ≥ 0.8 mm
Conductor material silver-plated Cu litz wires
Conductor structure signal line 7x 0.25 mm
AWG signal line 22
Conductor cross section 4x 0.34 mm²
Material wire insulation PE-X
Wire diameter incl. insulation 1.95 mm
Single wire, color white-blue, orange-yellow
Overall twist Star quad
Shielding Plastic-coated aluminum foil, tinned copper braided shield
Optical shield covering 100 %
Nominal voltage, cable 300 V AC
Test voltage, cable 2000 V AC (50 Hz, 5 minutes)
Conductor resistance ≤ 54.4 Ω/km
Coupling resistance 200.00 mΩ/m (f ≤ 30 MHz)
Wave impedance 100 Ω ±5 Ω (f = 100 MHz)
Working capacitance ≤ 65 pF (core-core)
≤ 100 pF (core-shield)
Signal speed 66 c
Minimum bending radius, fixed installation 6 x D
Minimum bending radius, flexible installation 10 x D
Damping 2 dB (with 1 MHz)
4 dB (at 4 МHz)
6.5 dB (at 10 MHz)
10.5 dB (at 31.5 МHz)
14 dB (at 62.5 МHz)
18 dB (at 100 MHz)
Remote crosstalk attenuation (FEXT) 80 dB (with 1 MHz)
70 dB (at 4 МHz)
65 dB (at 10 MHz)
58 dB (at 31.5 МHz)
59 dB (at 62.5 МHz)
67 dB (at 100 MHz)
Near end crosstalk attenuation (NEXT) 80 dB (with 1 MHz)
76 dB (at 4 МHz)
67 dB (at 10 MHz)
60 dB (at 31.5 МHz)
56 dB (at 62.5 МHz)
53 dB (at 100 MHz)
Return loss (RL) 35 dB (at 4 МHz)
35 dB (at 10 MHz)
35 dB (at 31.5 МHz)
33 dB (at 62.5 МHz)
33 dB (at 100 MHz)
Shield attenuation 40 dB (30 MHz ≤ f ≤ 100 MHz)
Fire protection in rail vehicles BS 6853 (Category Ia, Ib, II)
GM/RT 2130 (Category Ia, Ib, II)
EN 45545 (Risk level HL1 - HL3)
DIN 5510 (Fire protection level 1, 2, 3, 4)
NF F16-101 (Category A1, A2, B)
NF F16-101 (Class C/F0)
NFPA 130
UNI CEI 11170 (Risk level LR1 - LR4)
Halogen-free According to EN 50267-2-1
Resistance to oil according to IRM 902, 72 h at 100 °C
Concentration of fumes BS 6853 D.8.7
EN 61034-2
UL 1685, 12 (FT4)
Fume toxicity BS 6853 B.1
EN 50305, 9.2
Fume corrosiveness EN 50267-2-2
Flame resistance EN 60332-1-2
EN 50266
EN 60332-3-25
NF C32-070, 2.1
NF C32-070, 2.2
UL 1685, 12 (FT4)
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Other resistance Resistance to fuels according to IRM 903, 168 h at 70 °C
Ambient temperature (operation) -40 °C ... 90 °C (Cable, flexible installation)
-50 °C ... 90 °C (cable, fixed installation)
PROFINET BETAtrans® railway application CAT5 [939]
Dimensional drawing
Shielded yes
Cable weight 71 kg/km
Cable type PROFINET BETAtrans® railway application CAT5
Cable type (abbreviation) 939
Signal type/category PROFINET CAT5 (IEC 11801), 100 Mbps
Cable structure 1x4xAWG22/7; SF/TQ
External cable diameter 6.6 mm ±0.2 mm
Outer sheath, material PE-X
External sheath, color black
Thickness, outer sheath 1 mm
Conductor material Tin-plated Cu litz wires
Conductor structure signal line 7x 0.25 mm
AWG signal line 22
Conductor cross section 4x 0.34 mm²
Material wire insulation Cell PE
Wire diameter incl. insulation 1.4 mm ±0.1 mm
Single wire, color white-blue, orange-yellow
Overall twist Star quad
Shielding Aluminum-lined polyester foil, tinned copper braided shield
Nominal voltage, cable 125 V
Test voltage Core/Core 1000 V AC (50 Hz, 1 min.)
Test voltage Core/Shield 1000 V AC (50 Hz, 1 min.)
Conductor resistance ≤ 54.4 Ω/km
Cable insulation resistance ≥ 5 GΩ*km
Coupling resistance < 13.00 mΩ/m (f = 1 MHz)
< 8.00 mΩ/m (f = 10 MHz ... 100 MHz)
Wave impedance 100 Ω ±5 Ω (f = 100 MHz)
Cable capacity 44 nF/km (core-core)
Cable impedance 100 Ω ±15 Ω (f = 0.5 MHz ... 3 MHz)
Signal runtime 4.4 ns/m
Signal speed 0.75 c
Tensile strength ≤ 60 N (temporary)
≤ 15 N (Permanent)
Minimum bending radius, fixed installation 5 x D
Minimum bending radius, flexible installation 6 x D
Damping 1.5 dB (with 1 MHz)
3.3 dB (at 4 МHz)
5.3 dB (at 10 MHz)
6.9 dB (at 16 MHz)
9.9 dB (at 31.25 МHz)
14.5 dB (at 62.5 МHz)
18.8 dB (at 100 MHz)
23.6 dB (at 155 MHz)
27.3 dB (at 200 MHz)
Near end crosstalk attenuation (NEXT) 76 dB (with 1 MHz)
71 dB (at 4 МHz)
64 dB (at 10 MHz)
60 dB (at 16 MHz)
56 dB (at 31.25 МHz)
52 dB (at 62.5 МHz)
48 dB (at 100 MHz)
45 dB (at 155 MHz)
42 dB (at 200 MHz)
Power-summated near end crosstalk attenuation (PSNEXT) 73 dB (with 1 MHz)
68 dB (at 4 МHz)
61 dB (at 10 MHz)
57 dB (at 16 MHz)
53 dB (at 31.25 МHz)
49 dB (at 62.5 МHz)
45 dB (at 100 MHz)
42 dB (at 155 MHz)
39 dB (at 200 MHz)
Return loss (RL) 25 dB (with 1 MHz)
25 dB (at 4 МHz)
28 dB (at 10 MHz)
28 dB (at 16 MHz)
27 dB (at 31.25 МHz)
26 dB (at 62.5 МHz)
25 dB (at 100 MHz)
25 dB (at 155 MHz)
23 dB (at 200 MHz)
Shield attenuation 60 dB (up to 1000 MHz)
Fire protection in rail vehicles BS 6853 (Internal cable Ia, Ib, II/external cable Ia, Ib, II)
DIN 5510-2 (Fire protection level 1, 2, 3, 4)
EN 45545-2 (Risk level HL1 - HL3)
EN 50306-4
NF F16-101 (Classification C/F1)
NF F16-101 (Internal cable A1, A2, B/external cable A1, A2, B)
NFPA 130
PN-K-02511
UIC 564-2 (Class A)
Halogen-free According to EN 50267-2-1
according to EN 60684-2
Resistance to oil according to EN 60684-2, 72 h at 100 °C, IRM 902
Concentration of fumes EN 61034-2
Flame resistance according to EN 60332-1-2
according to EN 50266-2-5
according to ISO 14572 5.21 (UN ECE-R 118.01)
Other resistance Resistant to fuel according to EN 60684-2, 72 h at 100 °C, IRM 903
Resistant to ozone according to EN 50306-4, 72 h at 40 °C, procedure B, volume concentration 200 x 10-6
Ambient temperature (operation) -25 °C ... 70 °C (Cable, flexible installation)
-40 °C ... 85 °C (cable, fixed installation)
Note This item is a network cable with a freely selectable cable type. The technical data for all possible cable types is listed in the table below.
Cable structure
Signal type/category PROFINET CAT5 (IEC 11801), 100 Mbps
Ethernet CAT5 (IEC 11801), 100 Mbps

Degree of protection IP65
Degree of protection IP65
Ambient temperature (operation) -40 °C ... 85 °C (Plug / socket)

M12
Standards/specifications IEC 61076-2-101
Standards/specifications EN 50155

Item number 1412181
Packing unit 1 pc
Minimum order quantity 1 pc
Sales Key BF1
Product Key BF1CJN
GTIN 4046356993791
Customs tariff number 85444290
Country of origin PL


ECLASS

ECLASS-9.0 27060308
ECLASS-10.0.1 27060308
ECLASS-11.0 27060307

ETIM

ETIM 8.0 EC001855

UNSPSC

UNSPSC 21.0

REACh SVHC Dechlorane Plus
China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Compatible Products


  1. Network cable NBC-MSD SCO RAIL/.../... - 1412178

  2. Torque screwdriver TSD 04 SAC - 1208429

  3. Network cable NBC-MRD SCO RAIL/.../... - 1412179

  4. Torque screwdriver TSD-M 1,2NM - 1212224

  5. Network cable NBC-MSD-MSD SCO RAIL/.../... - 1412177

  6. Adapter insert TSD-M SAC-BIT ADAPTER - 1212600

  7. Tool SAC BIT M12-D15 - 1208432

  8. Screw plug PROT-M12 MS-PA-CHAIN - 1430899

  9. Locking clip SAC-M12-EXCLIP-F - 1558991

  10. Marker pen B-STIFT - 1051993

  11. Conductor marker carrier PATG HF 3/18 - 1014059

  12. Conductor marker carrier PATG HF 3/23 - 1014060

  13. Conductor marker carrier PATG HF 3/30 - 1014061

  14. Conductor marker carrier PATG HF 4/18 - 1014065

  15. Conductor marker carrier PATG HF 4/23 - 1014066

  16. Conductor marker carrier PATG HF 4/30 - 1014067

  17. Cable marker carrier KMK HP (25X6) - 0830720

  18. Cable marker carrier KMK HP (29X8) - 0830721

  19. Cable marker WMTB HF (40X12)R YE - 0830408

  20. Cable marker WMTB HF (55X15)R YE - 0830410

  21. Cable marker WMTB HF (55X25)R YE - 0830412

  22. Shrink sleeve WMS-2 HF 6,4 (60X10)RL YE - 0801025

  23. Shrink sleeve WMS-2 HF 6,4 (EX10)RL YE - 0833244

  24. Shrink sleeve WMS-2 HF 9,5 (60X16)RL YE - 0801029

  25. Shrink sleeve WMS-2 HF 9,5 (EX16)RL YE - 0833245

  26. Wire marking UCT-WMCO 5,4 (23X8) - 0832105

  27. Wire marking UCT-WMCO 6,1 (23X8) - 0832106

  28. Wire marking UCT-WMCO 6,8 (23X8) - 0832107

  29. Wire marking UCT-WMCO 7,5 (23X8) - 0832108

  30. Cable marker WMTB-AL (40X15) - 0830524

  31. Cable marker WMTB-AL (60X15) - 0830525

  32. Cable marker LS-WMTB-AL (40X15) - 0831501

  33. Cable marker LS-WMTB-AL (40X15) BK - 0831509

  34. Cable marker LS-WMTB-AL (60X15) - 0831502

  35. Cable marker LS-WMTB-AL (60X15) BK - 0831510

  36. Cable marker LS-WMTB-AL (100X15) - 0831503

  37. Cable marker LS-WMTB-AL (100X15) BK - 0831511

  38. Cable-cutting tool CUTFOX 12 - 1212128

  39. Diagonal cutter CUTFOX-S VDE - 1212207

  40. Diagonal cutter MICROFOX-SP-1 - 1212487

  41. Stripping tool WIREFOX 4 - 1212156

  42. Stripping tool WIREFOX-E 4 - 1212704

  43. Stripping tool WIREFOX 10 - 1212150

  44. Data connector SACC-MSD-4QO SH PN SCO - 1411068

  45. Data connector SACC-FSD-4QO SH PN SCO - 1411071

  46. Data connector SACC-M12MSD-4PL SH PN - 1424682

  47. Data connector SACC-M12MRD-4PL SH PN - 1424684

  48. Data connector SACC-M12FSD-4PL SH PN - 1424683

  49. Data connector SACC-M12FRD-4PL SH PN - 1424685

  50. Data connector SACC-M12MSD-4CT-CM SH PN - 1422846

  51. Data connector SACC-M12MRD-4CT-CM SH PN - 1422847

  52. Data connector SACC-M12FSD-4CT-CM SH PN - 1422848

  53. Data connector SACC-M12FRD-4CT-CM SH PN - 1422849

  54. Data connector SACC-PO12MSD-4CT-CM SH PN - 1021830

  55. Data connector SACC-PO12MRD-4CT-CM SH PN - 1021831

  56. Data connector SACC-MSD-4QO SH ETH SCO - 1411066

  57. Data connector SACC-FSD-4QO SH ETH SCO - 1411069


Your advantages

Easy and safe: 100% electrically tested plug-in components
Securely locked by special vibration brake
Resistant to temperature influences – tested for an extended temperature range and for resistance to temperature shocks
Reliable signal transmission – 360° shielding in environments with electromagnetic interference