EV-HPC-PCU-01
   - 
  Cooling unit
    
      1237881
      
      
    
  
      CHARX connect, CCS type 1, CCS type 2, Cooling unit, Accessories, length: 1.5 m, with variable-speed fan, with variable-speed pump, for cooling the cooling liquid of a Phoenix Contact HPC DC charging cable
Product details
| Product type | Cooling unit | 
| Product family | CHARX connect | 
| Technology | High Power Charging | 
| Combined Charging System | |
| Application | for cooling the cooling liquid of a Phoenix Contact HPC DC charging cable | 
| for installation in e-mobility charging stations (EVSE) | |
| Design | with variable-speed fan | 
| with variable-speed pump | |
| Manufacturer | HYDAC Cooling GmbH | 
| Charging standard | CCS type 1 | 
| CCS type 2 | |
| Charging mode | Mode 4 | 
| Cooling system | |
| Cooling | Liquid-air cooling system (passive) | 
| semi-closed cooling circuit | |
| Coolant | 50% water, 50% glycol (Glysofor N) | 
| Volume range | ≤ 60 db(A) (with free-standing system and 1 m distance) | 
| Supply voltage | 24 V DC (Fan) | 
| 24 V DC (Pump) | |
| Control voltage range | 0.00 V DC ... 10.00 V DC (Fan) | 
| 0.00 V DC ... 10.00 V DC (Pump) | |
| Current consumption | max. 1.97 A (Fan) | 
| max. 1.8 A (Pump) | |
| Function interface: Cooling system | |
| Interface description | Quick release couplings, inflow and return flow, for hoses with an outer diameter of 12 mm | 
| Function interface: Fan | |
| Cable structure | 4 x 0.5 mm² | 
| Single-core wire | Power supply RD | 
| Reference ground BU | |
| Speed output WH | |
| Control input YE | |
| Function interface: Pump | |
| Cable structure | 2 x 0.34 mm² + 5 x 0.14 mm² | 
| Single-core wire | Power supply RD | 
| Reference ground BK | |
| Motor shutoff signal GN | |
| Speed output BN | |
| Control input YE | |
| RS-485 Modbus WH can only be used by the manufacturer | |
| RS-485 Modbus BU can only be used by the manufacturer | |
| Function interface: Level sensor | |
| connection | Plug straight M12 A | 
| Material (Housing) | Aluminum | 
| Stainless steel | 
| Cable length | 1.5 m (Fan) | 
| 1.5 m (Pump) | |
| Cable length | 1.5 m (Fan) | 
| Cable length | 1.5 m (Pump) | 
| Cooling capacity | approx. 0.06 kW/K (at 2 l/min) | 
| Volumetric flow | approx. 2 l/min (at 1 bar) | 
| Coolant | 50% water, 50% glycol (Glysofor N) | 
| Ambient conditions | |
| Degree of protection (Fans) | IP55 (Fan) | 
| Degree of protection (Pump) | IP65 (Pump) | 
| Ambient temperature (operation) | -20 °C ... 50 °C | 
| Ambient temperature (storage/transport) | -25 °C ... 50 °C | 
| Altitude | max. 1000 m (above sea level) | 
| Volume range | ≤ 60 db(A) (with free-standing system and 1 m distance) | 
| Item number | 1237881 | 
| Packing unit | 1 pc | 
| Minimum order quantity | 1 pc | 
| Sales key | XWB | 
| Product key | XWBLNY | 
| GTIN | 4063151344757 | 
| Weight per piece (including packing) | 17 440 g | 
| Weight per piece (excluding packing) | 16 299 g | 
| Customs tariff number | 84195080 | 
| Country of origin | DE | 
ECLASS
| ECLASS-13.0 | 27144792 | 
| ECLASS-15.0 | 27144792 | 
ETIM
| ETIM 9.0 | EC002884 | 
UNSPSC
| UNSPSC 21.0 | 39121500 | 
| EU RoHS | |
| Fulfills EU RoHS substance requirements | Yes | 
| Exemption | 6(a), 6(a)-I, 7(c)-I | 
| China RoHS | |
| Environment friendly use period (EFUP) | EFUP-50 An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required. | 
| EU REACH SVHC | |
| REACH candidate substance (CAS No.) | Lead titanium zirconium oxide (CAS: 12626-81-2) | 
| Lead (CAS: 7439-92-1) | |
| SCIP | 052e4ff5-7318-4019-8f73-22974279b3e6 | 
Compatible products
PHOENIX CONTACT (Pty) Ltd.
        
        36 Lyn Road P.O. Box 916 ZA-Ferndale 2160