System connection - PLC-V8/FLK14/IN/M
2304115

V8 adapter for 8 x PLC-INTERFACE (6.2 mm), controller: PLC system cabling of input cards, connection 1: Screw connection 1x, connection 2: IDC/FLK pin strip 1x 14-position, connection 3: Plug-in connection (Can be snapped onto 8x PLC-INTERFACE terminals), number of channels: 8, control logic: minusschaltend

This product needs further products for operation. Mandatory Accessories

Product Details




Product type Controller board
Number of positions 14
No. of channels 8
Insulation characteristics
Overvoltage category II
Pollution degree 2

No. of channels 8
Max. permissible operating voltage 30 V DC
Nominal voltage UN 24 V DC
Max. current carrying capacity per branch 1 A (per signal path)
Max. total current of voltage supply 3 A
Rated insulation voltage 50 V
Rated surge voltage 0.5 kV (Functional insulation)
Supported controller SIEMENS S7-1500
Suitable I/O card 6ES7521-1BH50-0AA0
Supported controller ABB S800 I/O
Suitable I/O card DI814
Supported controller Emerson DeltaV
Suitable I/O card VE4001S2T2B3 Series 2
VE4001S5T2B5
VE4001S2T2B5
Supported controller MITSUBISHI MELSEC Q
Suitable I/O card QY41P
QY42P
QH42P
Supported controller MITSUBISHI MELSEC L
Suitable I/O card LY41NT1P
LY42NT1P

Supply
Connection method Screw connection
Stripping length 8 mm
Screw thread M3
Number of connections 1
Conductor cross section solid 0.2 mm² ... 4 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 12
Supply
Connection method IDC/FLK pin strip
Number of connections 1
Number of positions 14
Pitch 2.54 mm
Supply
Connection method Plug-in connection
Note Can be snapped onto 8x PLC-INTERFACE terminals

Status display Green LED
Status display present yes

Width 50 mm
Height 39 mm
Depth 56 mm

Flammability rating according to UL 94 V0
Housing insulation material Polyamide PA non-reinforced

Ambient conditions
Degree of protection IP20
Ambient temperature (operation) -40 °C ... 70 °C
Ambient temperature (storage/transport) -40 °C ... 70 °C

UL, USA / Canada
Identification Class I, Div. 2, Groups A, B, C, D T4
UL, USA / Canada
Identification Class I, Zone 2, Ex nA IIC Gc T4 X
UL, USA / Canada
Identification Class I, Zone 2, AEx nA IIC T4
UL, USA / Canada
Certificate TAE0000196
DNV GL data
Temperature D
Humidity A
Vibration C
Enclosure Required protection according to the Rules shall be provided upon installation on board

Standards/regulations IEC 60664
DIN EN 50178

Mounting type Plug-on assembly
Assembly instructions in rows with zero spacing
Mounting position any

Item number 2304115
Packing unit 1 pc
Minimum order quantity 1 pc
Sales Key 086
Product Key CK21C1
Catalog Page Page 427 (C-5-2019)
GTIN 4017918924423
Weight per Piece (including packing) 110,6 g
Weight per Piece (excluding packing) 107,9 g
Customs tariff number 85369010
Country of origin DE


ECLASS

ECLASS-9.0 27141152
ECLASS-10.0.1 27141152
ECLASS-11.0 27141152

ETIM

ETIM 8.0 EC002780

UNSPSC

UNSPSC 21.0 39121400

cUL Recognized

Approval ID: FILE E 238705
Approval Specification Data
Nominal Voltage UN Nominal Current IN Cross Section AWG Cross Section mm2
24 V 1 A

UL Recognized

Approval ID: FILE E 238705
Approval Specification Data
Nominal Voltage UN Nominal Current IN Cross Section AWG Cross Section mm2
24 V 1 A

DNV GL

Approval ID: TAE0000196
Approval Specification Data
Nominal Voltage UN Nominal Current IN Cross Section AWG Cross Section mm2

PRS

Approval ID: TE/2109/880590/16

UL Listed

Approval ID: FILE E 172140

cUL Listed

Approval ID: FILE E 172140

cUL Listed

Approval ID: FILE E 199827

UL Listed

Approval ID: FILE E 199827

cULus Recognized

cULus Listed

cULus Listed


REACh SVHC Lead 7439-92-1
Hexahydromethylphthalic anhydride
China RoHS Environmentally Friendly Use Period = 50 years
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads”

Compatible Products