Data connector - SACC-MSB-2QO SH PB SCO
1413931

Data connector, PROFIBUS DP (12 Mbps), 2-position, halogen-free, shielded, Plug straight M12 SPEEDCON, Coding: B, Insulation displacement connection, knurl material: Zinc die-cast, nickel-plated, external cable diameter 5 mm ... 9.7 mm


Product Details




Assembly instruction: NOTE: Observe the permissible bending radii when laying conductors, since the degree of protection may be put in jeopardy if the bending forces are too high. Alleviate mechanical loads upstream of the connector, e.g. by using cable ties.

Product type Circular connector (cable-side)
Number of positions 2
No. of cable outlets 1
Shielded yes
Coding B - inverse
Cable outlet straight
Insulation characteristics
Overvoltage category II
Degree of pollution 3

Degree of protection IP65
IP67
Ambient temperature (operation) -40 °C ... 85 °C (Plug / socket)
Ambient temperature (assembly) -5 °C ... 50 °C

Dimensional drawing
Length 58 mm
External dimensions
Outside diameter 5 mm ... 9.7 mm
Housing
Diameter housing 19 mm

Insertion/withdrawal cycles ≥ 100
Header 1
Head design Plug
Head cable outlet straight
Head thread type M12
Head locking type SPEEDCON
Coding B-coded

Rated surge voltage 0.8 kV
Insulation resistance ≥ 100 MΩ
Nominal voltage UN 48 V AC
60 V DC
Nominal current IN 4 A

Flammability rating according to UL 94 V0
Sealing material NBR
Material of grip body Zinc die-cast, nickel-plated
Contact material CuSn
Contact surface material Ni/Au
Contact carrier material PA 6.6
Cable gland material Zinc die-cast, nickel-plated
Standards/regulations PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, R24, and R26 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)
Wire insulation material PVC / PE / PP / rubber

Connection technology
Connection method Insulation displacement connection
Outside diameter 5 mm ... 9.7 mm
Conductor connection
Connection method Insulation displacement connection
Conductor cross section flexible 0.25 mm² ... 0.75 mm²
Cross section AWG 24 ... 18
Pin assignment
Contact | Color (signal designation) | Contact (optional) 2 = GN (A)
4 = RD (B)

Testing
Standards/regulations PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, R24, and R26 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)
M12
Standards/specifications according to IEC 61076-2-101

Cable structure
Signal type/category PROFIBUS DP, 12 Mbps

Item number 1413931
Packing unit 1 pc
Minimum order quantity 1 pc
Sales Key BF2
Product Key BF2CDC
Catalog Page Page 201 (C-6-2019)
GTIN 4055626012223
Weight per Piece (including packing) 40,5 g
Weight per Piece (excluding packing) 40 g
Customs tariff number 85366990
Country of origin DE


ECLASS

ECLASS-9.0 27440102
ECLASS-10.0.1 27440102
ECLASS-11.0 27440102

ETIM

ETIM 8.0 EC002635

UNSPSC

UNSPSC 21.0

EAC

Approval ID: RU C-DE.BL08.B.00511

China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Your advantages

Safe use in the field, thanks to a high degree of protection
Insulation displacement connection: innovative and time-saving assembly without stripping the single wire
Reliable signal transmission - 360° shielding in environments with electromagnetic interference
Save time, thanks to installation with SPEEDCON fast locking system