Circular connector (cable-side) - SACC-M12MSB-5PL SH IB 1424674

Data connector, INTERBUS (500 kbps), 5-position, shielded, Plug straight M12, Coding: B, Push-in connection, knurl material: Zinc die-cast, nickel-plated, external cable diameter 4 mm ... 8 mm


Product Details




Assembly instruction: NOTE: Observe the permissible bending radii when laying conductors, since the degree of protection may be put in jeopardy if the bending forces are too high. Alleviate mechanical loads upstream of the connector, e.g. by using cable ties.

Number of positions 5
Coding B - inverse
Insulation characteristics
Overvoltage category II
Degree of pollution 3

Degree of protection IP65
IP67
Degree of protection IP65/IP67
Ambient temperature (operation) -40 °C ... 85 °C (Plug / socket)

Dimensional drawing
Length 60 mm
External dimensions
External diameter 4 mm ... 8 mm
Housing
Diameter housing 19 mm

Insertion/withdrawal cycles ≥ 100
Header 1
Type Plug straight

Rated surge voltage 1.5 kV
Contact resistance ≤ 5 mΩ
Insulation resistance ≥ 100 MΩ
Nominal voltage UN 48 V AC
60 V DC
Nominal current IN 4 A (2 A when using 0.14 mm² conductors)

Material TPE-U (Clamping cage, weight: 1.1 g)
PA 6 (Actuation lever)
Flammability rating according to UL 94 V0
Sealing material NBR
Material of grip body Zinc die-cast, nickel-plated
Contact material CuSn
Contact surface material Ni/Au
Contact carrier material PA 6.6
Cable gland material Zinc die-cast, nickel-plated
Standards/regulations PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, R24, R25, and R26 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)
PA 6: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)

Connection technology
Connection method Push-in connection
External diameter 4 mm ... 8 mm
Conductor connection
Connection method Push-in connection
Conductor cross section flexible 0.14 mm² ... 0.75 mm²
Cross section AWG 26 ... 18

Assembly instructions The wires can be connected both with ferrules and without ferrules

Standards/specifications IEC 61076-2-101
EN 50155:2001
Testing
Standards/regulations PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, R24, R25, and R26 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)
PA 6: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)

Cable structure
Signal type/category INTERBUS, 500 kbps
Stripping length of the individual wire 7 mm


Order Key 1424674
Packing unit 1 pc
Minimum order quantity 1 pc
Sales Key BF2
Catalog Page Page 201 (C-6-2019)
GTIN 4055626376011
Weight per Piece (including packing) 37,3 GRM
Weight per Piece (excluding packing) 37,3 GRM
Customs tariff number 85366990
Country of origin DE



EAC

UL Listed

Approval Specification Data
Nominal voltage UN 60 V
Nominal current IN 4 A
AWG/kcmil
Min. cross section 26 mm²
Max. cross section 18 mm²

cUL Listed

Approval Specification Data
Nominal voltage UN 60 V
Nominal current IN 4 A
AWG/kcmil
Min. cross section 26 mm²
Max. cross section 18 mm²

EAC

cULus Listed


China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values


Your advantages

Conveniently connect stranded conductors, thanks to lever
Easy and tool-free connection by means of Push-in Technology
Flexible signal and data cabling
Quick and easy installation, thanks to Push-in connection technology
Reliable and quick connection of electric cables