TRIO3-UPS/1AC/24DC/5
   - 
  Uninterruptible power supply
    
      1359613
      
      
    
  
      TRIO UPS - UPS with integrated power supply, DIN rail mounting, Push-in connection, output: 24 V DC / 5 A
      This product needs further products for operation.
      Mandatory accessories
    
  Product details
| Input voltage range | 100 V AC ... 240 V AC -15 % ... +10 % | 
| 115 V AC ... 240 V AC ±10 % (UL) | |
| Voltage type of supply voltage | AC | 
| Inrush current integral (I2t) | typ. < 0.5 A2s | 
| Inrush current limitation | typ. < 21 A | 
| Frequency range (fN) | 50 Hz ... 60 Hz ±10 % | 
| Mains buffering time | typ.  45 ms (120 V AC) | 
| Static Boost (IStat.Boost) | 5 A | 
| Switch-on time during battery operation (Bat.-Start) | < 10 ms | 
| Discharge current to PE | < 3.5 mA | 
| Current consumption | typ. 2.29 A (100 V AC) | 
| Current consumption IN (UN, IOUT = IN, Icharge = 0) | 1.2 A (120 V AC) | 
| Current consumption Imax (UN, IOUT = IStat.Boost, ICharge = max) | 2.12 A (120 V AC) | 
| Current consumption INo-Load(UN, IOUT = 0, Icharge = 0) | 0.11 A (120 V AC) | 
| Current consumption Icharge (UN, IOUT = 0, Icharge = max) | 0.92 A (120 V AC) | 
| Power consumption PN (UN, IOUT = IN, Icharge = 0) | 130 W (120 V AC) | 
| Power consumption Pmax (UN, IOUT = IStat.Boost, Icharge = max) | 248 W (120 V AC) | 
| Power consumption PNo-Load (UN, IOUT = 0, Icharge = 0) | 4.3 W (120 V AC) | 
| Power consumption Pcharge (UN, IOUT = 0, Icharge = max) | 101 W (120 V AC) | 
| Input fuse | 6.3 A (internal (device protection)) | 
| Recommended breaker for input protection | 6 A ... 16 A | 
| Efficiency | typ. 92.8 % (120 V AC) | 
| typ. 93.3 % (230 V AC) | |
| Short-circuit-proof | yes | 
| No-load proof | yes | 
| Crest factor | typ. 1.72 (120 V AC) | 
| typ. 1.96 (230 V AC) | |
| Switch-over time | < 3 ms | 
| Output current limit | 5 A | 
| UPS connection in parallel | yes, with diode module uncoupled | 
| UPS connection in series | no | 
| Energy storage device connection in parallel | yes, max. 3 | 
| Energy storage device connection in series | no | 
| Feedback voltage resistance | ≤ 35 V DC | 
| Protection against overvoltage at the output (OVP) | ≤ 35 V DC | 
| Residual ripple | < 25 mV | 
| Rise time | ≤ 1 s (UOut = 10 % ... 90 %) | 
| Mains operation | |
| Output voltage | 24 V DC | 
| Output voltage range | 24 V DC ... 28 V DC (>24 V, performance-limited) | 
| max. 120 W | |
| Output current IN | 5 A | 
| Dynamic BOOST IDyn.Boost (IDyn.Boost) | 7.5 A (5 s) | 
| Output power PN | 120 W | 
| Output power PDyn. Boost | 180 W (5 s) | 
| Maximum no-load power dissipation | ≤ 6 W (120 V AC) | 
| ≤ 6 W (230 V AC) | |
| Power loss nominal load max. | ≤ 10 W (120 V AC) | 
| ≤ 10 W (230 V AC) | |
| Battery operation | |
| Output voltage | UBAT -0.1 V DC | 
| Output voltage range | 19.2 V DC ... 32 V DC | 
| Output current IN | 5 A | 
| Dynamic BOOST IDyn.Boost (IDyn.Boost) | 7.5 A (5 s) | 
| Output power PN | 120 W | 
| Output power PDyn. Boost | 180 W (5 s) | 
| Output power POUT (UN, IOUT = Idyn.Boost) | 180 W (5 s) | 
| Maximum no-load power dissipation | ≤ 1.5 W (120 V AC) | 
| ≤ 1.5 W (230 V AC) | |
| Power loss nominal load max. | ≤ 2 W (120 V AC) | 
| ≤ 2 W (230 V AC) | |
| Nominal voltage UN | 24 V DC | 
| Charging voltage | max. 32 V DC | 
| Charging current (Preset) | 1 A | 
| Charging current (Configurable) | 0.2 A ... 3 A (-25 °C ... 55 °C 5K) | 
| Charging current (Reduced) | 3 A ... 2.25 A (55°C ... 65°C  5K) | 
| Charging current (max.) | 3 A | 
| Nominal capacity range | 1.2 Ah ... 40 Ah | 
| Battery technology | VRLA-AGM | 
| Charge characteristic curve | IU0U | 
| Input | |
| Position | 1.x | 
| Connection technology | |
| Position marking | 1.1 (L/+), 1.2 (N/-), 1.3 () | 
| Conductor connection | |
| Connection method | Push-in connection | 
| rigid | 0.2 mm² ... 4 mm² | 
| 1.5 mm² | |
| flexible | 0.2 mm² ... 2.5 mm² | 
| 1.5 mm² | |
| flexible with ferrule without plastic sleeve | 0.25 mm² ... 2.5 mm² | 
| 1.5 mm² | |
| flexible with ferrule with plastic sleeve | 0.25 mm² ... 2.5 mm² | 
| 1.5 mm² | |
| AWG | 24 ... 12 | 
| 16 | |
| Stripping length | 10 mm | 
| Output | |
| Position | 2.x | 
| Connection technology | |
| Position marking | 2.1 (+), 2.2 (+), 2.3 (-), 2.4 (-) | 
| Conductor connection | |
| Connection method | Push-in connection | 
| rigid | 0.2 mm² ... 4 mm² | 
| 1.5 mm² | |
| flexible | 0.2 mm² ... 2.5 mm² | 
| 1.5 mm² | |
| flexible with ferrule without plastic sleeve | 0.25 mm² ... 2.5 mm² | 
| 1.5 mm² | |
| flexible with ferrule with plastic sleeve | 0.25 mm² ... 2.5 mm² | 
| 1.5 mm² | |
| AWG | 24 ... 12 | 
| 16 | |
| Stripping length | 10 mm | 
| Battery | |
| Position | 4.x | 
| Connection technology | |
| Position marking | 4.1 (+), 4.2 (-) | 
| Conductor connection | |
| Connection method | Push-in connection | 
| rigid | 0.2 mm² ... 10 mm² | 
| 2.5 mm² | |
| flexible | 0.2 mm² ... 6 mm² | 
| 2.5 mm² | |
| flexible with ferrule without plastic sleeve | 0.25 mm² ... 6 mm² | 
| 2.5 mm² | |
| flexible with ferrule with plastic sleeve | 0.25 mm² ... 4 mm² | 
| 2.5 mm² | |
| AWG | 24 ... 8 | 
| 14 | |
| Stripping length | 12 mm | 
| Signal | |
| Position | 3.x | 
| Conductor connection | |
| Connection method | Push-in connection | 
| rigid | 0.2 mm² ... 1.5 mm² | 
| 0.5 mm² | |
| flexible | 0.2 mm² ... 1.5 mm² | 
| 0.5 mm² | |
| flexible with ferrule without plastic sleeve | 0.2 mm² ... 1.5 mm² | 
| 0.5 mm² | |
| flexible with ferrule with plastic sleeve | 0.2 mm² ... 0.75 mm² | 
| 0.5 mm² | |
| AWG | 24 ... 16 | 
| 20 | |
| Stripping length | 8 mm | 
| LED signaling | |
| Types of signaling | LED: DC output | 
| Function | Visualization of the operating state of the DC output voltage (DC OK) | 
| Color | red, yellow, green (multicolor LED) | 
| LED off | Device off (Off) | 
| LED on (green), DC OK | Output power in operation < 90% (On (green), DC OK) | 
| LED on (yellow), IOut > 90 % | Output power in operation > 90% (On (yellow), IOut > 90% ) | 
| LED on (red), ISHORT | Output power overload > 150% (On (red), ISHORT) | 
| LED on (flashing red) OVP | UOUT > OVP (Over voltage protection) (on (flashing red 50%)) | 
| LED signaling | |
| Types of signaling | LED: device state | 
| Function | Visual display of the operating state of the UPS | 
| Color | red, yellow, green (multicolor LED) | 
| LED off | Device off (Off) | 
| LED on (green) | Device on (on (green)) | 
| LED on (flashing green 90%) | Remote contact is short-circuited with Output (-). (on (flashing green 90%)) | 
| LED on (flashing green 10 %) | Signaling time after shutdown in battery operation (on (flashing green 10%)) | 
| LED on (yellow) | Battery operation (on (yellow)) | 
| LED on (flashing yellow) | Battery charging (on (flashing yellow 50%)) | 
| LED on (red) | Group alarm, device (on (red)) | 
| LED on (flashing red) | Service mode for battery (on (flashing red 50%)) | 
| LED signaling | |
| Types of signaling | LED: battery condition | 
| Function | Visual display of the operating state of the battery | 
| Color | red, yellow, green (multicolor LED) | 
| LED off | Device off (Off) | 
| LED on (green) | Battery SOH > 6 months (on (green)) | 
| LED on (yellow) | Battery SOH < 6 months (on (yellow)) | 
| LED on (red) | Group alarm, battery (on (red)) | 
| LED on (flashing red) | Battery SOH = 0 months (on (flashing red 50%)) | 
| Signal input Bat.-Start | |
| Signalization designation | Bat.-Start | 
| Position | 3.x | 
| Position marking | 3.6 (Bat.-Start) | 
| Low signal | Connection to Output (-) with < 2.7 kΩ | 
| High signal | Open (> 200 kΩ between Bat.-Start and Output (-)) | 
| Signal input Remote | |
| Signalization designation | Remote | 
| Position | 3.x | 
| Position marking | 3.7 (Remote) | 
| Low signal | Connection to Output (-) with < 2.7 kΩ | 
| High signal | Open (> 200 kΩ between Remote and Output (-)) | 
| Signal input Temp.-Sensor | |
| Signalization designation | Temp.-Sensor | 
| Position | 3.x | 
| Position marking | 3.8 (Temp.-Sensor), 3.9 (Temp.-Sensor) | 
| Voltage | max. 3.5 V (when the sensor is not connected) | 
| Short-circuit current rating | max. 3 mA | 
| Signal output DC OK | |
| Position | 3.x | 
| Signalization designation | DC OK | 
| Position marking | 3.1 (DC OK) | 
| State condition (Contact closed (battery operation)) | UOut > 20.4 V; UOut < 32 V | 
| State condition (Contact open (battery operation)) | UOut < 20.4 V; UOut > 32 V | 
| Switching output | Transistor output, active | 
| Output voltage | 24 V DC | 
| Continuous load current | 20 mA | 
| LED status indicator | green (LED: DC output) | 
| Signal output Battery Mode | |
| Position | 3.x | 
| Signalization designation | Bat.-Mode | 
| Position marking | 3.2 (Bat.-Mode) | 
| State condition (Contact closed) | Device in battery mode | 
| State condition (Contact open) | Device in mains mode or device off | 
| Switching output | Transistor output, active | 
| Output voltage | 24 V DC | 
| Continuous load current | 20 mA | 
| LED status indicator | yellow (LED: device state) | 
| Signal output | |
| Position | 3.x | 
| Signalization designation | Bat.-Service | 
| Position marking | 3.3 (Bat.-Service) | 
| State condition (Contact closed) | Device in battery mode | 
| State condition (Contact open) | Device in mains mode or device off | 
| Switching output | Transistor output, active | 
| Output voltage | 24 V DC | 
| Continuous load current | 20 mA | 
| LED status indicator | red, flashing (LED: device status) | 
| Signal output Alarm | |
| Position | 3.x | 
| Signalization designation | Alarm | 
| Position marking | 3.4 (Alarm) | 
| State condition (Contact closed) | no alarm | 
| State condition (Contact open) | Alarm | 
| Switching output | Transistor output, active | 
| Output voltage | 24 V DC | 
| Continuous load current | 20 mA | 
| LED status indicator | red (LED: battery status) | 
| Signal output Ready | |
| Position | 3.x | 
| Signalization designation | Ready | 
| Position marking | 3.5 (Ready) | 
| State condition (Contact closed (mains operation)) | Battery is fully charged | 
| State condition (Contact closed (battery operation)) | As long as output voltage > cut-off voltage | 
| State condition (Contact open (mains operation)) | Battery charging | 
| State condition (Contact open (battery operation)) | Output voltage < cut-off voltage or device is switched off | 
| Switching output | Transistor output, active | 
| Output voltage | 24 V DC | 
| Continuous load current | 20 mA | 
| Product type | DC UPS with integrated power supply | 
| Product family | TRIO UPS | 
| MTBF (IEC 61709, SN 29500) | 1229684 h (25 °C) | 
| 749673 h (40 °C) | |
| 353116 h (60 °C) | |
| Insulation characteristics | |
| Protection class | I | 
| Degree of pollution | 2 | 
| Item dimensions | |
| Width | 68 mm | 
| Height | 135 mm | 
| Depth | 132 mm | 
| Depth (Device depth (DIN rail mounting)) | 125 mm (Device depth (DIN rail mounting)) | 
| Installation dimensions | |
| Installation distance right/left | 0 mm / 0 mm | 
| Installation distance top/bottom | 50 mm / 50 mm | 
| Mounting type | DIN rail mounting | 
| Mounting position | horizontal DIN rail NS 35, EN 60715 | 
| Material (Housing front) | PS | 
| Flammability rating according to UL 94 (housing / terminal blocks) | V0 | 
| Housing material | Aluminum | 
| Ambient conditions | |
| Degree of protection | IP20 | 
| Ambient temperature (operation) | -25 °C ... 70 °C | 
| Ambient temperature (operation) (Output power derating) | > 60 °C (2.5 %/K) | 
| Ambient temperature (storage/transport) | -40 °C ... 85 °C | 
| Maximum altitude | ≤ 5000 m ( 3000 m DIN EN 61558-2-16) | 
| Maximum altitude (Output power derating) | > 2000 m (10 %/1000 m) | 
| Climatic class | 3K3 (EN 60721) | 
| Shock | 18 ms, 30g, per spatial direction | 
| Vibration (operation) | 5 Hz ... 100 Hz, amplitude ±2.5 mm, 2.3g | 
| 30 Hz ... 100 Hz, 2.3g, 90 min. | |
| Overvoltage category | |
| EN 61010-1 | III (≤ 2000 m) / II (≤ 5000 m) | 
| EN 61010-2-201 | III (≤ 2000 m) / II (≤ 5000 m) | 
| Safety of power supply units up to 1100 V (insulation distances) | |
| Standard designation | Safety of power supply units up to 1100 V (insulation distances) | 
| Standards/specifications | DIN EN 61558-2-16 | 
| Electrical safety | |
| Standard designation | Electrical safety | 
| Standards/specifications | IEC 61010-2-201 (SELV) | 
| Electronic equipment for use in power installations | |
| Standard designation | Equipping high voltage installations with electronic equipment | 
| Standards/specifications | EN 50178/VDE 0160 (PELV) | 
| Safety for measurement, control, and laboratory equipment | |
| Standard designation | Safety for equipment for measurement, control, and laboratory use | 
| Standards/specifications | IEC 61010-1 | 
| Protective extra-low voltage | |
| Standard designation | Protective extra-low voltage | 
| Standards/specifications | IEC 61010-1 (SELV) | 
| IEC 61010-2-201 (PELV) | |
| Safe isolation | |
| Standard designation | Safe isolation | 
| Standards/specifications | IEC 61010-2-201 | 
| Limitation of harmonic line currents | |
| Standard designation | Limitation of harmonic line currents | 
| Standards/specifications | EN 61000-3-2 | 
| Mains variation/undervoltage | |
| Standard designation | Mains variation/undervoltage | 
| Standards/specifications | SEMI F47 | 
| EN 61000-4-11 | |
| UL | |
| Identification | UL/C-UL Listed UL 61010-1 | 
| UL | |
| Identification | UL/C-UL Listed UL 61010-2-201 | 
| ANSI/UL 121201 | |
| Identification | UL/C-UL Listed ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C | 
| Shipbuilding | |
| Identification | DNV | 
| Shipbuilding | |
| Identification | LR | 
| Shipbuilding | |
| Identification | Nippon Kaiji Kyokai | 
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU | 
| Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC | 
| Interference emission | Interference emission in accordance with EN 61000-6-3 (residential areas), EN 61000-6-4 (industrial areas) and EN 61000-6-8 (commercial areas) | 
| Noise immunity | Immunity in accordance with EN 61000-6-2 (industrial) | 
| Conducted noise emission | |
| Standards/regulations | EN 61000-6-3 | 
| Noise emission | |
| Standards/regulations | EN 61000-6-3 | 
| Harmonic currents | |
| Standards/regulations | EN 61000-3-2 | 
| Flicker | |
| Standards/regulations | EN 61000-3-3 | 
| Electrostatic discharge | |
| Standards/regulations | EN 61000-4-2 | 
| Electrostatic discharge | |
| Contact discharge | 6 kV (Test Level 3) | 
| Discharge in air | 8 kV (Test Level 3) | 
| Electromagnetic HF field | |
| Standards/regulations | EN 61000-4-3 | 
| Electromagnetic HF field | |
| Frequency range | 80 MHz ... 6 GHz | 
| Test field strength | 10 V/m | 
| Frequency range | 1.4 GHz ... 6 GHz | 
| Test field strength | 3 V/m | 
| Fast transients (burst) | |
| Standards/regulations | EN 61000-4-4 | 
| Fast transients (burst) | |
| Input | ± 4 kV (100 kHz) | 
| Output | ± 2 kV (100 kHz) | 
| Signal | ± 2 kV (100 kHz) | 
| Voltage (Battery) | ± 2 kV (100 kHz) | 
| Surge voltage load (surge) | |
| Standards/regulations | EN 61000-4-5 | 
| Surge voltage load (surge) | |
| Input | 2 kV (Test Level 4 - symmetrical) | 
| 4 kV (Test Level 4 - asymmetrical) | |
| Output | 1 kV (Test Level 3 - symmetrical) | 
| 2 kV (Test Level 3 - asymmetrical) | |
| Signal | 1 kV (Test Level 2 - asymmetrical) | 
| Conducted interference | |
| Standards/regulations | EN 61000-4-6 | 
| Conducted interference | |
| Frequency range | 0.15 MHz ... 80 MHz | 
| Voltage | 10 V | 
| Item number | 1359613 | 
| Packing unit | 1 pc | 
| Minimum order quantity | 1 pc | 
| Sales key | CM25 | 
| Product key | CMUD13 | 
| GTIN | 4063151689964 | 
| Weight per piece (including packing) | 999.8 g | 
| Weight per piece (excluding packing) | 920 g | 
| Customs tariff number | 85044095 | 
| Country of origin | CN | 
ECLASS
| ECLASS-13.0 | 27040705 | 
| ECLASS-15.0 | 27040705 | 
ETIM
| ETIM 9.0 | EC000382 | 
UNSPSC
| UNSPSC 21.0 | 39121000 | 
| EU RoHS | |
| Fulfills EU RoHS substance requirements | Yes | 
| Exemption | 34, 6(c), 7(a), 7(c)-I | 
| China RoHS | |
| Environment friendly use period (EFUP) | 
              EFUP-25
               An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required. 
             | 
          
| EU REACH SVHC | |
| REACH candidate substance (CAS No.) | Hexahydromethylphthalic anhydride (CAS: n/a) | 
| Lead (CAS: 7439-92-1) | |