Extension module - PSR-MC82-5NO-1NC-1DO-24DC-SC
2702382

Contact extension up to SIL 3, Cat. 4, PL e in conjunction with suitable evaluation device, 5 enabling current paths, US = 24 V DC, plug-in screw terminal block

Downloads

Product Details




Product type Safety relays
Application Extension module
Relay type Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Insulation characteristics
Overvoltage category III
Times
Typical response time < 50 ms (Monitored/manual and auto-start)
Typ. starting time with Us < 50 ms (when controlled via A1/A2)
Typical release time < 25 ms (when controlled via A1/A2)
Recovery time < 100 ms

Maximum power dissipation for nominal condition 15.2 W (at US = 30 V, IL² = 64 A²)
Nominal operating mode 100% operating factor
Designation A1/A2
Rated control circuit supply voltage US 19.2 V DC ... 30 V DC
Rated control circuit supply voltage US 24 V DC -20 % / +25 %
Rated control supply current IS typ. 80 mA
Power consumption at US typ. 1.92 W
Inrush current typ. 125 mA (Δt = 7 ms at Us)
Filter time 4 ms (at A1 in the event of voltage dips at Us)
max. 1 ms (at A1/A2, test pulse width, blanking pulses/dark test)
5 ms (at A1/A2, test pulse rate, blanking pulses/dark test)
Where test pulse width < 1 ms: test pulse rate = 5 x test pulse width
max. 1 ms (at A1/A2, test pulse width, switch-on pulses/light test)
10 ms (at A1/A2; test pulse rate; switch-on pulses/light test)
Deactivate the switch-on pulses for safety applications.
Protective circuit Surge protection; Suppressor diode
Reverse polarity protection; Universal diode
Rated insulation voltage 250 V AC
Rated insulation voltage 250 V AC
Rated surge voltage/insulation  

Relay: Enabling current paths (23/24 ... 63/64)
Output description safety-related N/O contacts
Number of outputs 5 (undelayed)
Contact type 5 enabling current paths
Contact material AgSnO2
Switching voltage min. 5 V AC/DC
max. 24 V DC (Enabling current path 23/24)
max. 250 V AC/DC (all other enabling current paths, observe load curve)
Switching capacity min. 50 mW (5 V / 10 mA)
Inrush current min. 10 mA
max. 20 A (≤ 100 ms)
Switching capacity according to IEC 60947-5-1 3 A (24 V (DC13))
3 A (250 V (AC15))
Limiting continuous current 6 A (observe derating)
Sq. Total current 64 A2 (observe derating)
Switching frequency max. 0.5 Hz
Mechanical service life 10x 106 cycles
Output fuse 10 A gL/gG
6 A gL/gG (for low-demand applications)
Relay: Confirmation current path (11/12)
Output description Safety-related N/C contacts
Number of outputs 1 (undelayed)
Contact type 1 confirmation current path
Contact material AgSnO
Switching voltage min. 5 V AC/DC
max. 24 V DC
Switching capacity min. 50 mW
Inrush current min. 10 mA
max. 100 mA
Limiting continuous current 100 mA
Switching frequency max. 0.5 Hz
Mechanical service life 10x 106 cycles
Output fuse 1 A gL/gG
Signal: M1
Output description non-safety-related
Number of outputs 1 (digital, PNP)
Voltage typ. 23 V DC (US - 1 V)
Current max. 100 mA
Maximum inrush current 500 mA (Δt = 1 ms at Us)
Short-circuit protection Yes

Connection technology
pluggable yes
Conductor connection
Connection method Screw connection
Conductor cross section solid 0.2 mm² ... 2.5 mm²
Conductor cross-section AWG 24 ... 12
Screw thread M3

Status display 2 x green LEDs

Width 17.5 mm
Height 112.2 mm
Depth 114.5 mm

Housing material Polyamide
Housing color yellow

Safety data
Stop category 0
Safety data: EN ISO 13849
Category 4 (In conjunction with suitable evaluating device)
Performance level (PL) e (In conjunction with suitable evaluating device)
Safety data: IEC 61508 - High demand
Equipment type Type A
Safety Integrity Level (SIL) 3 (In conjunction with suitable evaluating device)
SFFTwo-channel 100 %
MTBF 93.52 Years
λSU 651.49 FIT
λSD 49.29 FIT
λDU 0.03 FIT
λDD 6.49 FIT
Probability of a hazardous failure per hour (PFHD) 1.00 x 10-9
Proof test interval 240 Months
Duration of use 240 Months
Safety data: IEC 61508 - Low demand
Equipment type Type A
Safety Integrity Level (SIL) 3 (In conjunction with suitable evaluating device)
Safe Failure Fraction (SFF) 99.72 %
MTBF 51.3 Years
λSU 2005.99 FIT
λSD 45.18 FIT
λDU 5.76 FIT
λDD 0 FIT
Probability of a hazardous failure on demand (PFDAVG) 1.2 x 10-4
1.2 x 10-4
Proof test interval 38 Months
Duration of use 240 Months

Ambient conditions
Degree of protection IP20
Min. degree of protection of inst. location IP54
Ambient temperature (operation) -20 °C ... 60 °C (observe derating)
Ambient temperature (storage/transport) -40 °C ... 80 °C
Maximum altitude max. 2000 m (Above sea level)
Max. permissible humidity (storage/transport) 75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation) 75 % (on average, 85% infrequently, non-condensing)
Shock 15g (In the event of stress caused by shock, contact reactions are possible for up to 6 ms.)
Vibration (operation) 10 Hz ... 150 Hz, 2g (In the event of stress caused by vibration, contact reactions are possible for up to 1 ms.)

CE
Certificate CE-compliant

Air clearances and creepage distances between the power circuits
Standards/regulations EN 60947-1

Mounting type DIN rail mounting
Assembly instructions See derating curve
Mounting position vertical or horizontal

Item number 2702382
Packing unit 1 pc
Minimum order quantity 1 pc
Sales Key C18
Product Key DNA181
Catalog Page Page 228 (C-6-2019)
GTIN 4055626145471
Weight per Piece (including packing) 217.9 g
Weight per Piece (excluding packing) 215 g
Customs tariff number 85371098
Country of origin DE


ECLASS

ECLASS-9.0 27371819
ECLASS-10.0.1 27371819
ECLASS-11.0 27371819

ETIM

ETIM 8.0 EC001449

UNSPSC

UNSPSC 21.0 39122200

UL Listed

Approval ID: FILE E 140324

cUL Listed

Approval ID: FILE E 140324

Functional Safety

Approval ID: 44-205-15124303

cULus Listed


REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads”

Your advantages

Up to Cat. 4/PL e in accordance with ISO 13849-1, SIL 3 in accordance with IEC 62061 in conjunction with suitable evaluation device
Low housing width of just 17.5 mm
1- and 2-channel control
5 enabling current paths, 1 confirmation current path, 1 digital signal output
Automatic activation