Repeater power supply - MACX MCR-SL-RPSSI-2I
2924825

Measuring transducer repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4…20 mA electrically isolated signals from the field to two loads. 4-way electrical isolation, screw connection, SIL, PL.


Product Details




Utilization restriction
EMC note EMC: class A product, see manufacturer's declaration in the download area

Product type Repeater power supplies
No. of channels 1
Type Signal conditioners with SIL and PL Functional Safety
Insulation characteristics
Overvoltage category II
Pollution degree 2

No. of channels 1
Electrical isolation 3-way isolation
Electrical isolation between input and output yes
Maximum power dissipation for nominal condition 1.45 W (24 V DC / 20 mA)
Step response (10-90%) 1.3 ms (for jump 4 mA ... 20 mA, typical)
Maximum temperature coefficient < 0.01 %/K
Maximum transmission error < 0.1 % (of final value)
Transmission error, typical < 0.05 % (of final value)
Electrical isolation Input/output/power supply
Rated insulation voltage 300 Vrms
Test voltage 2.5 kV AC (50 Hz, 60 s)
Insulation Safe isolation in accordance with IEC/EN 61010-1
Electrical isolation Output 1/output 2
Test voltage 1.5 kV AC (50 Hz, 60 s)
Supply
Designation Repeater power supply operation
Nominal supply voltage 24 V DC
Supply voltage range 19.2 V DC ... 30 V DC (24 V DC, -20 % ... +25  %)
Max. current consumption < 75 mA (24 V DC / 20 mA)
Power dissipation < 1.45 W (24 V DC / 20 mA)
Supply
Designation Signal conditioner operation
Nominal supply voltage 24 V DC
Nominal supply voltage range 19.2 V DC ... 30 V DC (24 V DC, -20 % ... +25  %)
Max. current consumption < 46 mA (24 V DC / 20 mA)
Power dissipation < 1.2 W (24 V DC / 20 mA)

Signal
Description of the input Repeater power supply operation
Number of inputs 1
Current input signal 4 mA ... 20 mA
Transmitter supply voltage > 21.5 V (20 mA)
> 21 V (23 mA)
Underload/overload signal range 0 mA ... 24 mA (Extended transmission range for diagnostics)
Signal
Description of the input Signal conditioner operation
Current input signal 0 mA ... 20 mA
4 mA ... 20 mA
Voltage drop < 3.9 V (in input isolating amplifier operation)
Underload/overload signal range 0 mA ... 24 mA (Extended transmission range for diagnostics)

Signal: Repeater power supply operation
Output description Repeater power supply operation
Number of outputs 2
Current output signal 4 mA ... 20 mA (active)
0 mA ... 20 mA
Load/output load current output < 450 Ω (20 mA)
< 380 Ω (23 mA)
Output ripple < 20 mVrms
Output behavior in the event of an error 0 mA (Cable break in the input)
≥ 23 mA (Cable short-circuit in the input)
Underload/overload signal range 0 mA ... 24 mA (Extended transmission range for diagnostics)
Signal: Signal conditioner operation
Output description Signal conditioner operation
Current output signal 0 mA ... 20 mA (active)
4 mA ... 20 mA (active)
Load/output load current output < 450 Ω (20 mA)
< 380 Ω (23 mA)
Output ripple < 20 mVrms
Output behavior in the event of an error 0 mA (Cable break in the input)
0 mA (Cable short-circuit in the input)
Underload/overload signal range 0 mA ... 24 mA (Extended transmission range for diagnostics)

Connection method Screw connection
Stripping length 7 mm
Screw thread M3
Conductor cross section solid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 14
Torque 0.5 Nm ... 0.6 Nm
Max. diameter 2.3 mm

Data communication (bypass)
HART function Yes
Protocols supported HART

Status display Green LED (supply voltage)

Width 12.5 mm
Height 112.5 mm
Depth 113.7 mm
114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715)

Flammability rating according to UL 94 V0 (Housing)
Housing material PA 6.6-FR

Ambient conditions
Degree of protection IP20 (not assessed by UL)
Ambient temperature (operation) -20 °C ... 60 °C (Any mounting position)
Ambient temperature (storage/transport) -40 °C ... 80 °C
Altitude ≤ 2000 m
Permissible humidity (operation) 10 % ... 95 % (non-condensing)

CE
Certificate CE-compliant
Note and EN 61326-1
CE
Identification  II 3 G Ex nA IIC T4 Gc X
Certificate PxCCIF11ATEX2924825
CE
Identification  II 3 G Ex nA IIC T4 Gc
Certificate PxCIF21UKEX2924825X
CE
Identification UL 508 Listed
UL 61010 Listed
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Groups IIC, IIB, IIA T4
CE
Identification UL 61010 Listed
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Group IIC T4
CE
Identification C, EMC2
Certificate DNV GL TAA000020C
CE
Identification 2
CE
Identification d
CE
Identification  2Ex nA IIC T4 Gc
Certificate BY/112 02.01 TP012 103.01 00078
DNV GL data
Temperature B
Humidity B
Vibration A
EMC A
Enclosure Required protection according to the Rules shall be provided upon installation on board

Electromagnetic compatibility Conformance with EMC directive
Noise emission EN 61000-6-4
Noise immunity EN 61000-6-2
Note When being exposed to interference, there may be minimal deviations.
Electromagnetic HF field
Designation Electromagnetic RF field
Standards/regulations EN 61000-4-3
Typical deviation from the measuring range final value 3 %
Fast transients (burst)
Designation Fast transients (burst)
Standards/regulations EN 61000-4-4
Typical deviation from the measuring range final value 3 %
Conducted interference
Designation Conducted interferences
Standards/regulations EN 61000-4-6
Typical deviation from the measuring range final value 3 %

Electrical isolation 3-way isolation

Mounting type DIN rail mounting

Item number 2924825
Packing unit 1 pc
Minimum order quantity 1 pc
Sales Key C01
Product Key CK1111
Catalog Page Page 121 (C-5-2019)
GTIN 4046356572040
Weight per Piece (including packing) 249 g
Weight per Piece (excluding packing) 158 g
Customs tariff number 85437090
Country of origin DE


ECLASS

ECLASS-9.0 27210120
ECLASS-10.0.1 27210120
ECLASS-11.0 27210120

ETIM

ETIM 8.0 EC002653

UNSPSC

UNSPSC 21.0 39121000

DNV GL

Approval ID: TAA000020C

UL Listed

Approval ID: FILE E 330267

cUL Listed

Approval ID: FILE E 330267

Functional Safety

Approval ID: BVS PB 13-10-04

EAC Ex

Approval ID: RU C-DE.AB72.B.02066

ATEX

Approval ID: PxCIF11ATEX2924825X

cUL Listed

Approval ID: FILE E 199827

UL Listed

Approval ID: FILE E 199827

cULus Listed

cULus Listed


REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads”

Your advantages

Power supply possible via DIN rail connector
Up to SIL 2 according to EN 61508
Installation in zone 2, protection type "n" (EN 60079-15) permitted
Two electrically isolated 0/4 mA ... 20 mA (active) outputs
Bidirectional transmission of digital HART communication signals (both outputs)
Plug-in screw or spring-cage connection technology (Push-in technology), with integrated sockets for HART communicators
Input: 0/4 mA ... 20 mA (powered or not powered)
4-way electrical isolation