Repeater power supply - MACX MCR-EX-SL-RPSSI-2I-SP
2924236

Ex i measuring transducer power supply and input signal conditioner, HART-transparent. Transfers supplied or active 0/4 mA ... 20 mA electrical isolation signals from the Ex area to two loads in the safe area. 4-way electrical isolation, Push-in connection, SIL, PL.


Product Details




Utilization restriction
EMC note EMC: class A product, see manufacturer's declaration in the download area

Product type Repeater power supplies
No. of channels 1
Type Ex i signal conditioners with SIL and PL Functional Safety
Insulation characteristics
Overvoltage category II
Pollution degree 2

No. of channels 1
Electrical isolation 3-way isolation
Electrical isolation between input and output yes
Step response (10-90%) 1.3 ms (for jump 4 mA ... 20 mA, typical)
Maximum temperature coefficient < 0.01 %/K
Maximum transmission error < 0.1 % (of final value)
Transmission error, typical < 0.05 % (of final value)
Electrical isolation Input/output/power supply
Rated insulation voltage 300 Vrms
Test voltage 2.5 kV AC (50 Hz, 60 s)
Insulation Safe isolation in accordance with IEC/EN 61010-1
Electrical isolation Input/output
Electrical isolation 375 V (Peak value in accordance with IEC/EN 60079-11)
Electrical isolation Input/power supply
Electrical isolation 375 V (Peak value in accordance with IEC/EN 60079-11)
Electrical isolation Output 1/output 2
Test voltage 1.5 kV AC (50 Hz, 60 s)
Supply
Designation Repeater power supply operation
Nominal supply voltage 24 V DC
Supply voltage range 19.2 V DC ... 30 V DC (24 V DC, -20 % ... +25  %)
Max. current consumption < 75 mA (24 V DC / 20 mA)
Power dissipation < 1.45 W (24 V DC / 20 mA)
Supply
Designation Signal conditioner operation
Nominal supply voltage 24 V DC
Nominal supply voltage range 19.2 V DC ... 30 V DC (24 V DC, -20 % ... +25  %)
Max. current consumption < 46 mA (24 V DC / 20 mA)
Power dissipation < 1.2 W (24 V DC / 20 mA)

Signal
Description of the input Repeater power supply operation
Number of inputs 1
Current input signal 4 mA ... 20 mA
Transmitter supply voltage > 16 V (20 mA)
> 15.1 V (23 mA)
Polarization and surge protection Yes
Underload/overload signal range 0 mA ... 24 mA (Extended transmission range for diagnostics)
Signal
Description of the input Signal conditioner operation
Current input signal 0 A ... 20 mA
4 mA ... 20 mA
Voltage drop < 3.9 V (in input isolating amplifier operation)
Underload/overload signal range 0 mA ... 24 mA (Extended transmission range for diagnostics)

Signal: Repeater power supply operation
Output description Repeater power supply operation
Number of outputs 2
Current output signal 4 mA ... 20 mA (Output 1 and output 2 active)
Load/output load current output < 450 Ω (20 mA)
< 380 Ω (23 mA)
Output ripple < 20 mVrms
Output behavior in the event of an error 0 mA (Cable break in the input)
≥ 23 mA (Cable short-circuit in the input)
Underload/overload signal range 0 mA ... 24 mA (Extended transmission range for diagnostics)
Signal: Signal conditioner operation
Output description Signal conditioner operation
Current output signal 0 mA ... 20 mA (active)
4 mA ... 20 mA (active)
Load/output load current output < 450 Ω (20 mA)
< 380 Ω (23 mA)
Output ripple < 20 mVrms
Output behavior in the event of an error 0 mA (Cable break in the input)
0 mA (Cable short-circuit in the input)
Underload/overload signal range 0 mA ... 24 mA (Extended transmission range for diagnostics)

Connection method Push-in connection
Stripping length 8 mm
Conductor cross section solid 0.2 mm² ... 1.5 mm²
Conductor cross section flexible 0.2 mm² ... 1.5 mm²
Conductor cross section AWG 24 ... 16

Safety data: Repeater power supply operation
Note Repeater power supply operation
Max. output voltage Uo 25.2 V
Max. output current Io 93 mA
Max. output power Po 587 mW
Safety-related maximum voltage Um 253 V AC
125 V DC
IIC (simple circuit): Max. external inductivity Lo / Max. external capacitance Co 300 mH / 3.6 µF
IIC (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co 100 mH / 510 nF
50 mH / 580 nF
5 mH / 600 nF
1 mH / 600 nF
10 µH / 600 nF
IIB/IIIC (simple circuit): Max. external inductivity Lo / Max. external capacitance Co 1000 mH / 26 µF
IIB/IIA/IIIC (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co 100 mH / 1 µF
5 mH / 1 µF
1 mH / 1 µF
10 µH / 1 µF
IIA (simple circuit): Max. external inductivity Lo / Max. external capacitance Co 1000 mH / 210 µF
Safety data: Signal conditioner operation
Note Signal conditioner operation
Input voltage Ui ≤ 30 V
Input current Ii ≤ 150 mA
Max. internal inductance Li negligible
Max. internal capacitance Ci negligible
Safety-related maximum voltage Um 253 V AC
125 V DC
Safety data: Repeater power supply operation
Note Repeater power supply operation
Max. output voltage Uo 25.2 V
Max. output current Io 93 mA
Max. output power Po 587 mW
Safety-related maximum voltage Um 253 V AC
125 V DC
IIC (simple circuit): Max. external inductivity Lo / Max. external capacitance Co 300 mH / 3.6 µF
IIC (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co 100 mH / 510 nF
50 mH / 580 nF
5 mH / 600 nF
1 mH / 600 nF
10 µH / 600 nF
IIB/IIIC (simple circuit): Max. external inductivity Lo / Max. external capacitance Co 1000 mH / 26 µF
IIB/IIA/IIIC (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co 100 mH / 1 µF
5 mH / 1 µF
1 mH / 1 µF
10 µH / 1 µF
IIA (simple circuit): Max. external inductivity Lo / Max. external capacitance Co 1000 mH / 210 µF
Safety data: Signal conditioner operation
Note Signal conditioner operation
Input voltage Ui ≤ 30 V
Input current Ii ≤ 150 mA
Max. internal inductance Li negligible
Max. internal capacitance Ci negligible
Safety-related maximum voltage Um 253 V AC
125 V DC

Data communication (bypass)
HART function Yes
Protocols supported HART

Status display Green LED (supply voltage)

Width 12.5 mm
Height 116 mm
Depth 113.7 mm
114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715)

Flammability rating according to UL 94 V0 (Housing)
Housing material PA 6.6-FR

Ambient conditions
Degree of protection IP20 (not assessed by UL)
Ambient temperature (operation) -20 °C ... 60 °C (Any mounting position)
Ambient temperature (storage/transport) -40 °C ... 80 °C
Altitude ≤ 2000 m
Permissible humidity (operation) 10 % ... 95 % (non-condensing)

CE
Certificate CE-compliant
Note and EN 61326
CE
Identification  II (1) G [Ex ia Ga] IIC
 II (1) D [Ex ia Da] IIIC
 II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
Certificate BVS 10 ATEX E 143 X
CE
Identification [Ex ia Ga] IIC
[Ex ia Da] IIIC
Ex nA [ia Ga] IIC T4 Gc
Certificate IECEx BVS 10.0097X
CE
Identification [Ex ia Ga] IIC
[Ex iaD]
Ex nA [ia Ga] IIC T4 Gc
Certificate NEPSI GYJ20.1308X
CE
Identification IS for Class I,II,III, Division 1 and Zone 0
Installation in Class I, Division 2 and Zone 2
Certificate , C.D.-No 83104549
CE
Identification Class I Div 2; IS for Class I, II, III Div 1
Certificate , C.D.-No 83104549
CE
Certificate DNV GL TAA000020C
CE
Identification 2
CE
Identification d
CE
Identification  [Ex ia Ga] IIC
 [Ex ia Da] IIIC
Certificate RU C-DE.AB72.B.00093/19
CE
Identification [Ex ia Ga] IIC
[Ex ia Da] IIIC
Ex nA [ia Ga] IIC T4 Gc
Certificate DNV 18.0139 X
DNV GL data
Temperature B
Humidity B
Vibration A
EMC A
Enclosure Required protection according to the Rules shall be provided upon installation on board

Electromagnetic compatibility Conformance with EMC directive
Noise emission EN 61000-6-4
Noise immunity EN 61000-6-2
Note When being exposed to interference, there may be minimal deviations.

Electrical isolation 3-way isolation
GB Standard
Standards/regulations GB 3626.20
GB 3836.1
GB 3836.4
GB 3836.8
GB 12476.1
GB 12476.4

Mounting type DIN rail mounting

Item number 2924236
Packing unit 1 pc
Minimum order quantity 1 pc
Sales Key C03
Product Key CK3111
Catalog Page Page 143 (C-5-2019)
GTIN 4046356463676
Weight per Piece (including packing) 241.3 g
Weight per Piece (excluding packing) 165 g
Customs tariff number 85437090
Country of origin DE


ECLASS

ECLASS-9.0 27210120
ECLASS-10.0.1 27210120
ECLASS-11.0 27210120

ETIM

ETIM 8.0 EC002653

UNSPSC

UNSPSC 21.0 39121000

DNV GL

Approval ID: TAA000020C

UL Listed

Approval ID: FILE E 330267

CCC

Approval ID: 2020322 316001579

cUL Listed

Approval ID: FILE E 330267

Functional Safety

Approval ID: BVS PB 13-10-04

EAC Ex

Approval ID: RU C-DE.AB72.B.00093

IECEx

Approval ID: IECEx BVS 10.0097X

cUL Listed

Approval ID: FILE E 199827

UL Listed

Approval ID: FILE E 199827

ATEX

Approval ID: BVS 10 ATEX E143 X

INMETRO

Approval ID: DNV 18.0139 X

cULus Listed

cULus Listed


REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads”

Your advantages

0/4 mA ... 20 mA input, intrinsically safe, [Ex ia], powered and not powered
Measuring transducer supply voltage > 16 V
Two electrically isolated 0/4 mA ... 20 mA (active) outputs
Bidirectional HART transmission (both outputs)
Error indication according to NAMUR NE 43
SIL 2 according to IEC/EN 61508
Safe electrical isolation between input, outputs, and supply
Power supply possible via DIN rail connector
Installation in zone 2 permitted
Plug-in connection terminals, push-in connection technology
Housing width: 12.5 mm
Minimal power dissipation
High transmission accuracy