Lightning/surge arrester type 1/2 - VAL-MS-T1/T2 600DC-PV/2+V-FM
2801164

Lightning current arrester / surge protective device for 2-pos. isolated and grounded 600 V DC PV voltage systems, for DIN rail mounting, 3-pos. base element with remote indication contact, three pluggable temperature-monitored protective elements, status message at each plug.


Product Details




General
Note The device is intended for touch proof installation in a housing. Ensure that there is a gap of at least 8 mm between the active and grounded parts in the connection area.

IEC test classification PV I / II
PV T1 / T2
EN type T1 / T2
IEC power supply system DC
Type DIN rail module, two-section, divisible
Distance between live and grounded parts 8 mm
Product type PV arrester
Installation location Interior
Installation location of the disconnect device Internal
Accessibility Accessible
Connection configuration Y configuration
SPD failure behavior OCFM (Open-Circuit Failure Mode)
Surge protection fault message Optical, remote indicator contact
Insulation characteristics
Overvoltage category III
Pollution degree 2

Indicator/remote signaling
Connection name Remote fault indicator contact
Switching function Changeover contact
Operating voltage 5 V AC ... 250 V AC
30 V DC
Operating current 5 mA AC ... 1.5 A AC
1 A DC

Connection method Screw connection
Screw thread M5
Tightening torque 3 Nm (1.5 mm² ... 16 mm²)
4.5 Nm (25 mm² ... 35 mm²)
Stripping length 16 mm
Conductor cross section flexible 1.5 mm² ... 25 mm²
Conductor cross section solid 1.5 mm² ... 35 mm²
Conductor cross section AWG 15 ... 2
Connection method Fork-type cable lug
Conductor cross section flexible 1.5 mm² ... 16 mm²
Remote fault indicator contact
Connection method Plug-in/screw connection via COMBICON
Screw thread M2
Tightening torque 0.25 Nm
Conductor cross section flexible 0.14 mm² ... 1.5 mm²
Conductor cross section solid 0.14 mm² ... 1.5 mm²
Conductor cross section AWG 28 ... 16

Dimensional drawing
Width 53.4 mm
Height 98.7 mm
Depth 65.7 mm (incl. DIN rail 7.5 mm)
Horizontal pitch 3 Div.

Color jet black RAL 9005
Flammability rating according to UL 94 V-0
CTI value of material 600
Insulating material PA 6.6-FR
PBT-FR
Material group I
Housing material PA 6.6-FR
PBT-FR

Mechanical data
Open side panel No

Mode of protection (L+) - (L-)
(L+) - PE
(L-) - PE
Direction of action (L+)-PE & (L-)-PE & (L+)-(L-)
Rated load current IL 80 A
Residual current IPE ≤ 20 µA DC
≤ 350 µA AC
Standby power consumption PC ≤ 25 mVA
Nominal discharge current In (8/20) µs 15 kA
Maximum discharge current Imax (8/20) µs 40 kA
Impulse discharge current (10/350) µs, charge 2.5 As
Impulse discharge current (10/350) µs, specific energy 6.25 kJ/Ω
Impulse discharge current (10/350) µs, peak value limp 5 kA
Total discharge current Itotal (8/20) µs 40 kA
Total discharge current Itotal (10/350) µs 7 kA
Voltage protection level Up ≤ 2.6 kV
Residual voltage Ures ≤ 2.6 kV (at In)
≤ 2 kV (at 5 kA)
≤ 2.3 kV (at 10 kA)
≤ 2.8 kV (at 20 kA)
≤ 3.1 kV (at 30 kA)
≤ 3.6 kV (at 40 kA)
Response time tA ≤ 25 ns
PV protective circuit
Connection configuration Y configuration
SPD failure behavior OCFM (Open-Circuit Failure Mode)
Protective circuit DC voltage side (DC)
Open circuit voltage UOCSTC ≤ 600 V DC
Maximum discharge current Imax (8/20) µs 40 kA
Response time tA ≤ 25 ns
Impulse discharge current (10/350) µs, charge 2.5 As
Impulse discharge current (10/350) µs, specific energy 6.25 kJ/Ω
Impulse discharge current (10/350) µs, peak value limp 5 kA
Total discharge current Itotal (8/20) µs 40 kA
Total discharge current Itotal (10/350) µs 7 kA
Insulation resistance Riso > 5 GΩ (at 500 V DC)
Nominal discharge current In (8/20) µs 15 kA
Rated load current IL 80 A
Continuous operating current ICPV < 20 µA
Maximum continuous operating voltage UCPV 720 V DC
Short-circuit current rating ISCPV 2000 A
Residual voltage Ures ≤ 2.6 kV (at In)
≤ 2 kV (at 5 kA)
≤ 2.3 kV (at 10 kA)
≤ 2.8 kV (at 20 kA)
≤ 3.1 kV (at 30 kA)
≤ 3.6 kV (at 40 kA)
Residual current IPE ≤ 20 µA DC
≤ 350 µA AC
Voltage protection level Up ≤ 2.6 kV
Standby power consumption PC ≤ 25 mVA

Ambient conditions
Degree of protection IP20 (only when all terminal points are used)
Ambient temperature (operation) -40 °C ... 80 °C
Ambient temperature (storage/transport) -40 °C ... 80 °C
Altitude ≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation) 5 % ... 95 %
Shock (operation) 60g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation) 7.5g (5-500 Hz/2.5 h/XYZ)

UL specifications
Maximum continuous operating voltage MCOV 800 V DC
Short-circuit current rating (SCCR) 50 kA
Voltage protection rating VPR 2 kV
Nominal discharge current In 20 kA
Mode of protection (L+) - (L-)
(L+) - G
(L-) - G
Nominal voltage 800 V DC
Power distribution system DC PV
SPD Type 1
UL indicator/remote signaling
AC operating voltage 125 V AC
AC operating current 1 A AC
UL connection data
Tightening torque 30 lbf-in.
Conductor cross section AWG 14 ... 2

Standards/specifications EN 61643-31
Standards/specifications IEC 61643-31

Mounting type DIN rail: 35 mm

Item number 2801164
Packing unit 1 pc
Minimum order quantity 1 pc
Sales Key C06
Product Key CL1152
Catalog Page Page 50 (C-4-2019)
GTIN 4046356714297
Weight per Piece (including packing) 371 g
Weight per Piece (excluding packing) 340.62 g
Customs tariff number 85363030
Country of origin DE


ECLASS

ECLASS-9.0 27130802
ECLASS-10.0.1 27130802
ECLASS-11.0 27130802

ETIM

ETIM 8.0 EC000381

UNSPSC

UNSPSC 21.0 39121600

EAC

Approval ID: RU C-DE.*09.B.00169

KEMA-KEUR

Approval ID: 71-123544 REV.2

UL Listed

Approval ID: FILE E 330181

cUL Listed

Approval ID: FILE E 330181

IECEE CB Scheme

Approval ID: NL-81006/A1

CCA

Approval ID: NTR-NL 7937
Approval Specification Data
Nominal Voltage UN Nominal Current IN Cross Section AWG Cross Section mm2

cULus Listed


China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Compatible Products

Your advantages

Quality proven millions of times over in the widest range of applications
Rapid installation with bridges, thanks to industry-standard overall width of 1 HP
Easy testing and insulation measurement, thanks to pluggable protection modules