FLKM-2KS50/BFI/SPT/CS
   - 
  Passive module
    
      2321813
      
      
    
  
      Termination board for Yokogawa ADV 151, ADV 161, ADV 551 and ADV 561 I/O modules with a fuse for cable protection (5 x 20) and fuse failure display (LED) per channel. Redundant system connection.
Product details
| Product type | Interface module | 
| No. of channels | 32 | 
| Operating mode | 100% operating factor | 
| Insulation characteristics | |
| Insulation | Functional insulation | 
| Overvoltage category | II | 
| Pollution degree | 2 | 
| Nominal voltage UN | 24 V DC | 
| 19.2 V DC ... 26.4 V DC | |
| Max. current carrying capacity per branch | 100 mA (observe derating) | 
| Max. total current of all branches | 4 A (observe derating) | 
| Rated insulation voltage | 50 V DC | 
| Rated surge voltage | 0.5 kV | 
| Supported controller YOKOGAWA CS3000 CentumVP | |
| Suitable I/O card | ADV151 | 
| ADV161 | |
| ADV551 | |
| ADV561 | |
| Supported controller YOKOGAWA STARDOM | |
| Suitable I/O card | NFDV151 | 
| NFDV161 | |
| NFDV551 | |
| NFDV561 | |
| Contact switching type | 1 N/O contact | 
| Type of switch contact | Double contact | 
| Contact material | AgNi, 5 µm hard gold-plated | 
| Maximum switching voltage | < 25 V AC | 
| 48 V DC | |
| Limiting continuous current | 1 A | 
| Min. switching current | 1 mA | 
| Interrupting rating (ohmic load) max. | 24 W (24 V DC) | 
| 48 W (48 V DC) | |
| 25 VA (25 V AC) | |
| Mechanical service life | approx. 2x 107 cycles | 
| Field level | |
| Connection method | Spring-cage connection | 
| Conductor cross-section rigid | 0.2 m² ... 4 mm² | 
| Conductor cross-section flexible | 0.2 mm² ... 2.5 mm² | 
| Conductor cross-section AWG | 24 ... 12 | 
| Controller level | |
| Connection method | Yokogawa, KS compatible | 
| Number of connections | 2 | 
| Number of positions | 50 | 
| Note | Usable system cables: Phoenix Contact YUC50, Yokogawa AKB331 | 
| Tightening torque | 0.5 Nm | 
| Status display | LED (red) | 
| Status display present | yes, if the fuse fails | 
| Operating voltage display | Green LED | 
| Item dimensions | |
| Width | 343.4 mm | 
| Height | 125.4 mm | 
| Depth | 70.8 mm | 
| Ambient conditions | |
| Degree of protection | IP00 | 
| Ambient temperature (operation) | -20 °C ... 50 °C | 
| Ambient temperature (storage/transport) | -20 °C ... 70 °C | 
| Altitude | ≤ 2000 m | 
| Standards/regulations | EN IEC 60664-1 | 
| Mounting type | DIN rail mounting | 
| Assembly note | in rows with zero spacing | 
| Mounting position | any | 
| Notes on operation | Voltage monitoring on the module does not work in combination with upstream HESILED fuse terminal blocks with integrated LED display. | 
| Notes on operation | Do not connect adjacent channels to SELV/ PELV and voltages dangerous to the touch. | 
| Notes on operation | No additional touch protection is required when using a SELV/PELV voltage (≤ 25 V AC or 60 V DC). | 
| Notes on operation | Against adjacent modules in the support rail direction at least one functional insulation on the output-side is complied with. If the application has higher requirements on the insulation (basic insulation or reinforced insulation), then these must be realized through suitable measures (e. g. partition plates). | 
| Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. | 
| Item number | 2321813 | 
| Packing unit | 1 pc | 
| Minimum order quantity | 1 pc | 
| Note | Made to order (non-returnable) | 
| Sales key | C421 | 
| Product key | DK218N | 
| GTIN | 4046356340595 | 
| Weight per piece (including packing) | 805.6 g | 
| Weight per piece (excluding packing) | 797 g | 
| Customs tariff number | 85369010 | 
| Country of origin | DE | 
ECLASS
| ECLASS-13.0 | 27141152 | 
| ECLASS-15.0 | 27141152 | 
ETIM
| ETIM 9.0 | EC002780 | 
UNSPSC
| UNSPSC 21.0 | 39121400 | 
| EU RoHS | |
| Fulfills EU RoHS substance requirements | Yes | 
| Exemption | 6(c), 7(a), 7(c)-I | 
| China RoHS | |
| Environment friendly use period (EFUP) | EFUP-50 An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required. | 
| EU REACH SVHC | |
| REACH candidate substance (CAS No.) | Hexahydromethylphthalic anhydride (CAS: n/a) | 
| Lead (CAS: 7439-92-1) | |
| SCIP | 8bc9c985-ebc2-4e94-844a-076df46a10e1 | 
Compatible products
- 
    
      
- 
    
      FLK-MIL50/EZ-DR/KS/2000/YCS - Cable 2314820
- 
    
      FLK-MIL50/EZ-DR/KS/3000/YCS - Cable 2901018
- 
    
      FLK-MIL50/EZ-DR/KS/3500/YCS - Cable 2901019
- 
    
      FLK-MIL50/EZ-DR/KS/4000/YCS - Cable 2901020
- 
    
      FLK-MIL50/EZ-DR/KS/4500/YCS - Cable 2902909
- 
    
      FLK-MIL50/EZ-DR/KS/8000/YCS - Cable 2321868
- 
    
      FLK-MIL50/EZ-DR/KS/ 200/YCS - Cable 2314590
- 
    
      FLK-MIL50/EZ-DR/KS/ 300/YCS - Cable 2314781
- 
    
      FLK-MIL50/EZ-DR/KS/ 400/YCS - Cable 2314794
- 
    
      FLK-MIL50/EZ-DR/KS/1000/YCS - Cable 2314804
- 
    
      FLK-MIL50/EZ-DR/KS/1200/YCS - Cable 2909875
- 
    
      FLK 50-PA/EZ-DR/KS/ 100/YUC - Front adapter 2900991
- 
    
      FLK 50-PA/EZ-DR/KS/ 200/YUC - Front adapter 2314299
- 
    
      FLK 50-PA/EZ-DR/KS/ 300/YUC - Front adapter 2314309
- 
    
      FLK 50-PA/EZ-DR/KS/ 400/YUC - Front adapter 2314312
- 
    
      FLK 50-PA/EZ-DR/KS/ 500/YUC - Front adapter 2321499
- 
    
      FLK 50-PA/EZ-DR/KS/ 600/YUC - Front adapter 2314927
- 
    
      FLK 50-PA/EZ-DR/KS/ 700/YUC - Front adapter 2321509
- 
    
      FLK 50-PA/EZ-DR/KS/ 800/YUC - Front adapter 2314930
- 
    
      FLK 50-PA/EZ-DR/KS/ 900/YUC - Front adapter 2321512
- 
    
      FLK 50-PA/EZ-DR/KS/1000/YUC - Front adapter 2314325
- 
    
      FLK 50-PA/EZ-DR/KS/1100/YUC - Front adapter 2321389
- 
    
      FLK 50-PA/EZ-DR/KS/1200/YUC - Front adapter 2321525
- 
    
      FLK 50-PA/EZ-DR/KS/1300/YUC - Front adapter 2321392
- 
    
      FLK 50-PA/EZ-DR/KS/1400/YUC - Front adapter 2321402
- 
    
      FLK 50-PA/EZ-DR/KS/1500/YUC - Front adapter 2314338
- 
    
      FLK 50-PA/EZ-DR/KS/1600/YUC - Front adapter 2321538
- 
    
      FLK 50-PA/EZ-DR/KS/1700/YUC - Front adapter 2321541
- 
    
      FLK 50-PA/EZ-DR/KS/1800/YUC - Front adapter 2321554
- 
    
      FLK 50-PA/EZ-DR/KS/1900/YUC - Front adapter 2321567
- 
    
      FLK 50-PA/EZ-DR/KS/2000/YUC - Front adapter 2314503
- 
    
      FLK 50-PA/EZ-DR/KS/2500/YUC - Front adapter 2314516
- 
    
      FLK 50-PA/EZ-DR/KS/3000/YUC - Front adapter 2314529
- 
    
      FLK 50-PA/EZ-DR/KS/5000/YUC - Front adapter 2318981
- 
    
      FLK 50-PA/EZ-DR/HF/KS/ 100/YUC - Front adapter 2904739
- 
    
      FLK 50-PA/EZ-DR/HF/KS/ 200/YUC - Front adapter 2904740
- 
    
      FLK 50-PA/EZ-DR/HF/KS/ 300/YUC - Front adapter 2904741
- 
    
      FLK 50-PA/EZ-DR/HF/KS/ 400/YUC - Front adapter 2904742
- 
    
      FLK 50-PA/EZ-DR/HF/KS/ 500/YUC - Front adapter 2904636
- 
    
      FLK 50-PA/EZ-DR/HF/KS/ 600/YUC - Front adapter 2904743
- 
    
      FLK 50-PA/EZ-DR/HF/KS/ 700/YUC - Front adapter 2904744
- 
    
      FLK 50-PA/EZ-DR/HF/KS/ 800/YUC - Front adapter 2904745
- 
    
      FLK 50-PA/EZ-DR/HF/KS/ 900/YUC - Front adapter 2904746
- 
    
      FLK 50-PA/EZ-DR/HF/KS/1000/YUC - Front adapter 2904637
- 
    
      FLK 50-PA/EZ-DR/HF/KS/1500/YUC - Front adapter 2904638
- 
    
      FLK 50-PA/EZ-DR/HF/KS/2000/YUC - Front adapter 2904487
- 
    
      FLK 50-PA/EZ-DR/HF/KS/2500/YUC - Front adapter 2904639
- 
    
      FLK 50-PA/EZ-DR/HF/KS/3000/YUC - Front adapter 2904640
- 
    
      FLK 50-PA/EZ-DR/HF/KS/3500/YUC - Front adapter 2904641
- 
    
      FLK 50-PA/EZ-DR/HF/KS/4000/YUC - Front adapter 2904642
- 
    
      FLK 50-PA/EZ-DR/HF/KS/4500/YUC - Front adapter 2904643
- 
    
      FLK 50-PA/EZ-DR/HF/KS/5000/YUC - Front adapter 2904644
PHOENIX CONTACT
        
        586 Fulling Mill Road, Middletown, PA 17057