MINI MCR-2-T-I-PT
   - 
  Temperature measuring transducer
    
      2908829
      
      
    
  
      Temperature transducer for converting and transmitting intrinsically signals from RTD and TC sensors to a load. Standard configuration, Push-in connection
      Free download available.
      Downloads
    
  Product details
| Product type | Temperature transmitter | 
| Product family | MINI Analog Pro | 
| Application | Temperature | 
| Configuration | Software | 
| App | 
| Functionality | |
| Configuration | Software | 
| App | |
| Electrical isolation between input and output | yes | 
| Step response (0–99%) | ≤ 250 ms | 
| Maximum temperature coefficient | 0.01 % | 
| Maximum transmission error | 0.1 % | 
| Electrical isolation | |
| Overvoltage category | II (≤ 5000 m) | 
| Pollution degree | 2 (≤ 5000 m) | 
| Electrical isolation Input/output/power supply IEC/EN 61010-1 | |
| Standards/regulations | IEC/EN 61010-1 | 
| Rated insulation voltage | 300 Vrms | 
| Test voltage | 2.5 kV AC (50 Hz, 60 s) | 
| Insulation | Double/reinforced insulation | 
| Electrical isolation Input/output/power supply IEC/EN 60079-7 | |
| Standards/regulations | IEC/EN 60079-7 | 
| Rated insulation voltage | 251 Vrms | 
| Supply | |
| Nominal supply voltage | 24 V DC | 
| Supply voltage range | 19.2 V DC ... 30 V DC | 
| Power consumption | ≤ 900 mW | 
| Measurement | |
| Sensor types (RTD) that can be used | Pt, Ni, Si, Cu sensors | 
| Sensor types that can be used (TC) | J, K, B, E, N, R, S, T, C, A, L, U, A-1, A-2, A-3, Lr, M | 
| Temperature measuring range | -200 °C ... 850 °C (Range depending on the sensor type) | 
| Connection technology | 2-, 3-, 4-conductor | 
| Linear resistance measuring range | 0 Ω ... 40 kΩ (Minimum measuring span: 10% of the selected measuring range) | 
| Potentiometer resistance range | 0 Ω ... 40 kΩ (Minimum measuring span: 10% of the selected measuring range) | 
| Linear mV signal range | -1000 mV ... 1000 mV | 
| Max. permissible overall conductor resistance | ≤ 25 Ω (adjustable, 3-, 4-conductor, per cable) | 
| ≤ 50 Ω (adjustable, 2-conductor) | |
| Signal: Current | |
| Number of outputs | 1 | 
| Configurable/programmable | Yes | 
| Current output signal | 4 mA ... 20 mA (NE 43) | 
| 0 mA ... 20 mA | |
| 20 mA ... 0 mA | |
| 0 mA ... 21 mA (freely adjustable) | |
| 21 mA ... 0 mA (freely adjustable) | |
| Load/output load current output | ≤ 600 Ω | 
| Connection method | Push-in connection | 
| Stripping length | 10 mm | 
| Conductor cross-section rigid | 0.2 mm² ... 1.5 mm² (with ferrule) | 
| 0.14 mm² ... 2.5 mm² (without ferrule) | |
| Conductor cross-section flexible | 0.14 mm² ... 2.5 mm² | 
| Conductor cross-section AWG | 24 ... 12 (flexible) | 
| Ex installation (EPL) | Gc | 
| Div. 2 | 
| Connection method | S-PORT | 
| Status display | Green LED (supply voltage) | 
| Red LED (error messages) | 
| Width | 6.2 mm | 
| Height | 109.81 mm | 
| Depth | 119.2 mm | 
| Color | gray (RAL 7042) | 
| Housing material | PBT | 
| Ambient conditions | |
| Degree of protection | IP20 | 
| Ambient temperature (operation) | -40 °C ... 70 °C (Any mounting position) | 
| Ambient temperature (storage/transport) | -40 °C ... 85 °C | 
| Permissible humidity (operation) | 5 % ... 95 % (at 25 °C, non-condensing) | 
| Altitude range (IEC/EN 61010-1) | |
| Height range | > 2000 m ... 3000 m | 
| Ambient temperature (operation) | -40 °C ... 63 °C | 
| Rated insulation voltage | 300 Vrms (Input/output/power supply) | 
| Insulation | Double/reinforced insulation | 
| Altitude range (IEC/EN 61010-1) | |
| Height range | > 3000 m ... 4000 m | 
| Ambient temperature (operation) | -40 °C ... 56 °C | 
| Rated insulation voltage | 300 Vrms (Input/output/power supply) | 
| Insulation | Double/reinforced insulation | 
| Altitude range (IEC/EN 61010-1) | |
| Height range | > 4000 m ... 5000 m | 
| Ambient temperature (operation) | -40 °C ... 49 °C | 
| Rated insulation voltage | 150 Vrms (Input/output/power supply) | 
| Insulation | Double/reinforced insulation | 
| Altitude range (IEC/EN 60079-7) | |
| Height range | > 2000 m ... 3000 m | 
| Ambient temperature (operation) | -40 °C ... 63 °C | 
| Rated insulation voltage | 162 Vrms (Input/output/power supply) | 
| Altitude range (IEC/EN 60079-7) | |
| Height range | > 3000 m ... 4000 m | 
| Ambient temperature (operation) | -40 °C ... 56 °C | 
| Rated insulation voltage | 60 Vrms (Input/output/power supply) | 
| Altitude range (IEC/EN 60079-7) | |
| Height range | > 4000 m ... 5000 m | 
| Ambient temperature (operation) | -40 °C ... 49 °C | 
| Rated insulation voltage | 60 Vrms (Input/output/power supply) | 
| CE | |
| Certificate | CE-compliant | 
| ATEX | |
| Identification |  II 3 G Ex ec ic IIC T4 Gc | 
| Certificate | IBExU 21 ATEX B007 X | 
| IECEx | |
| Identification | Ex ec ic IIC T4 Gc | 
| Certificate | IECEx IBE 21.0017 X | 
| CCC / China-Ex | |
| Identification | Ex ec IIC T4 Gc | 
| Certificate | 2023122310116238 | 
| UL, USA/Canada | |
| Identification | UL 61010-2-201 Listed | 
| Shipbuilding approval | |
| Certificate | DNV TAA00003FZ | 
| INMETRO | |
| Identification | Ex ec IIC T4 Gc | 
| Certificate | DNV 23.0187 X | 
| Shipbuilding data | |
| Temperature | B | 
| Humidity | B | 
| Vibration | A | 
| EMC | A | 
| Enclosure | Required protection according to the Rules shall be provided upon installation on board | 
| Electromagnetic compatibility | Tested in accordance with the following standards and regulations: EN 61326-1 For industrial use, NAMUR NE 21 | 
| Noise immunity | EN 61000-6-2 | 
| Noise emission | |
| Standards/regulations | EN 61000-6-4 | 
| GB Standard | |
| Standards/regulations | GB/T 3836.1 | 
| GB/T 3836.3 | |
| GB/T 3836.4 | |
| Mounting type | DIN rail mounting | 
| Mounting position | any | 
| Item number | 2908829 | 
| Packing unit | 1 pc | 
| Minimum order quantity | 1 pc | 
| Sales key | DK1125 | 
| Product key | DK1125 | 
| GTIN | 4055626364766 | 
| Weight per piece (including packing) | 118.8 g | 
| Weight per piece (excluding packing) | 118.8 g | 
| Country of origin | DE | 
ECLASS
| ECLASS-13.0 | 27210129 | 
| ECLASS-15.0 | 27210129 | 
ETIM
| ETIM 9.0 | EC002919 | 
UNSPSC
| UNSPSC 21.0 | 41112105 | 
| EU RoHS | |
| Fulfills EU RoHS substance requirements | Yes | 
| Exemption | 7(a), 7(c)-I | 
| China RoHS | |
| Environment friendly use period (EFUP) | EFUP-50 An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required. | 
| EU REACH SVHC | |
| REACH candidate substance (CAS No.) | Lead (CAS: 7439-92-1) | 
| 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol (CAS: 79-94-7) | |
Compatible products
- 
    
      ME 6,2 TBUS-2 1,5/5-ST-3,81 GY - DIN rail bus connector 2695439
- 
    
      ME 6,2 TBUS-2 1,5/5-ST-3,81 GN - DIN rail bus connector 2869728
- 
    
      MCR-DP - Separating plate 1430594
- 
    
      TC-D37SUB-AIO16-MP-PS-UNI - Module carrier 2906640
- 
    
      TC-D37SUB-ADIO16-MP-P-UNI - Module carrier 2906639
- 
    
      IFS-USB-PROG-ADAPTER - Programming adapter 2811271
- 
    
      IFS-BT-PROG-ADAPTER - Adapter 2905872
- 
    
      MINI MCR-2-V8-FLK 16 - System adapter 2901993
- 
    
      MINI MCR-2-V8-MOD-RTU - Communication module 2905634
- 
    
      MINI MCR-2-V8-MOD-TCP - Communication module 2905635
- 
    
      MINI MCR-2-V8-PB-DP - Communication module 2905636
- 
    
      MINI MCR-2-V8-PN - Communication module 2905637
- 
    
      FASTCON PRO-SET - Connector set 2906227
- 
    
      FASTCON PRO-SET-PT - Connector set 2906228
- 
    
      UCT-EM (30X5) - Marker for end clamp 0801505
- 
    
      UCT-EM (30X5) CUS - Marker for end clamp 0801589
- 
    
      SK 5,0 WH:REEL - Marker strip 0805221
- 
    
      UC-EMLP (15X5) - Plastic label 0819301
- 
    
      UC-EMLP (15X5) YE - Plastic label 0822615
- 
    
      UC-EMLP (15X5) CUS - Plastic label 0824550
- 
    
      UC-EMLP (15X5) YE CUS - Plastic label 0824551
- 
    
      UC-EMLP (15X5) SR - Plastic label 0828095
- 
    
      UC-EMLP (15X5) SR CUS - Plastic label 0828099
- 
    
      US-EMLP (15X5) - Plastic label 0828790
- 
    
      US-EMLP (15X5) YE - Plastic label 0828873
- 
    
      US-EMLP (15X5) SR - Plastic label 0828874
- 
    
      US-EMLP (15X5) CUS - Plastic label 0830076
- 
    
      US-EMLP (15X5) YE CUS - Plastic label 0830077
- 
    
      US-EMLP (15X5) SR CUS - Plastic label 0830078
- 
    
      UCT-EM (30X5) YE - Marker for end clamp 0830340
- 
    
      UCT-EM (30X5) YE CUS - Marker for end clamp 0830348
- 
    
      MINI MCR-2-PTB - Power terminal block 2902066
- 
    
      MINI MCR-2-PTB-PT - Power terminal block 2902067
- 
    
      QUINT4-SYS-PS/1AC/24DC/2.5/SC - Power supply 2904614
- 
    
      MINI MCR-2-FM-RC - Monitoring block 2904504
- 
    
      MINI MCR-2-FM-RC-PT - Monitoring block 2904508
- 
    
      SZS 0,6X3,5 - Screwdriver 1205053
PHOENIX CONTACT Ltd
        