The Wireless MUX transmits 16 digital and 2 analog signals bidirectionally. The Wireless MUX is supplied ready to use: Unpack – connect – switch on – and you have a working wireless path.
ILB BT ADIO MUX-OMNI
-
Wireless set
2884208
Wireless MUX set, two modules with 16 digital inputs and outputs and 2 analog inputs and outputs (0 ... 20 mA, 0 ... 10 V) each, RSMA (female) antenna connection, incl. omnidirectional antennas with 1.5 m cable
Product details
Note on application | |
Note on application | Only for industrial use |
Utilization restriction | |
EMC note | EMC: class A product, see manufacturer's declaration in the download area |
Product type | Wireless module |
Product family | Inline |
Application | I/O |
Type | Block design |
MTTF | 1458 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
557 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) | |
219 Years (SN 29500 standard, temperature 40°C, operating cycle 100%) | |
MTBF | 465 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
140 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) | |
Diagnostics messages | Short-circuit or overload of the digital outputs LED |
Wireless connection FS LED | |
Logic and actuator voltage LED | |
Link quality of the wireless connection 4 LEDs | |
Insulation characteristics | |
Overvoltage category | II |
Pollution degree | 2 |
Times | |
Switch-on time | ≤ 3 s (Until the wireless connection is established) |
Delay time | ≤ 10 ms (Latency, typical) |
≤ 800 ms (Failsafe function for wireless interruption) | |
Data management status | |
Article revision | 12 |
Maximum power dissipation for nominal condition | 2.4 W |
Supply: Module electronics | |
Connection method | Inline connector |
Supply voltage | 24 V DC |
Supply voltage range | 19.2 V DC ... 30.5 V DC (via power connector) |
Current consumption | 60 mA (Communications power at 24 V DC, 25 °C) |
25 mA (Actuator supply, +load current Digital OUT (8 A)) | |
Protective circuit | Polarity protection, surge protection |
Analog: | |
Input name | Analog inputs |
Description of the input | Single ended |
Number of inputs | 2 |
Current input signal | 0 mA ... 20 mA |
Input resistance current input | 50 Ω |
Voltage input signal | 0 V ... 10 V |
Input resistance of voltage input | 130 kΩ |
Measured value resolution | 12 bits |
Protective circuit | Surge voltage; Suppressor diodes in the analog inputs, current limitation via internal protective circuit |
Digital: | |
Input name | Digital inputs |
Number of inputs | 16 |
Connection method | Spring-cage connection |
Connection technology | 1-conductor |
Input voltage range "0" signal | < 5 V |
Input voltage range "1" signal | > 15 V |
Nominal input voltage UIN | 24 V DC |
Typical input current per channel | 2.3 mA |
Input frequency | ≤ 10 Hz |
Analog: | |
Output name | Analog outputs |
Number of outputs | 2 |
Protective circuit | Transient protection |
DAC resolution | 12 bit |
Current output signal | 0 mA ... 20 mA |
Load/output load current output | ≤ 500 Ω |
Voltage output signal | 0 V ... 10 V |
Load/output load voltage output | ≥ 2 kΩ |
Digital: | |
Output name | Digital outputs |
Connection method | Spring-cage connection |
Connection technology | 1-conductor |
Number of outputs | 16 |
Protective circuit | Short-circuit protection, overload protection, protected against reverse voltages |
Output current | 8 A (Total) |
Maximum output current per channel | 500 mA |
Nominal output voltage | 24 V DC |
Output current when switched off | ≤ 10 µA (When not loaded, a voltage can be measured even at an output that is not set.) |
Nominal load, inductive | 12 VA (1.2 H, 50 Ω) |
Nominal load, lamp | 12 W |
Nominal load, ohmic | 12 W (48 Ω) |
Reverse voltage resistance to short pulses | Reverse voltage proof |
Behavior with overload | Auto restart |
Behavior with inductive overload | Output can be destroyed |
Behavior at voltage switch-off | The output follows the power supply without delay |
Overcurrent shut-down | ≥ 0.7 A |
Conductor cross section, rigid | 0.2 mm² ... 1.5 mm² |
Conductor cross section, flexible | 0.2 mm² ... 1.5 mm² |
Conductor cross section, flexible [AWG] | ... 16 |
Stripping length | 8 mm |
Functions | |
Wireless licenses | Europe, USA, Canada, additional countries in the e-shop |
Wireless | |
Modulation type | GFSK (Gaussian Frequency Shift Keying) |
Antenna connection method | RSMA (female) |
No. of channels | 40 |
Frequency range | 2.402 GHz ... 2.48 GHz (ISM bandwidth) |
Frequency band | 2.4 GHz |
Wireless standard | Bluetooth |
Transmission power | 5 dBm |
Receiver sensitivity | -95.00 dBm |
Diagnostic messages | |
Diagnostics | Short-circuit or overload of the digital outputs |
Message | LED |
Diagnostic messages | |
Diagnostics | Wireless connection |
Message | FS LED |
Diagnostic messages | |
Diagnostics | Logic and actuator voltage |
Message | LED |
Diagnostic messages | |
Diagnostics | Link quality of the wireless connection |
Message | 4 LEDs |
Dimensional drawing | |
Width | 95 mm |
Height | 123.4 mm |
Depth | 57 mm |
Note on dimensions | with connectors |
Color (Housing) | green (RAL 6021) |
Material (Housing) | PA 6.6-FR |
Ambient conditions | |
Ambient temperature (operation) | -25 °C ... 60 °C |
Degree of protection | IP20 |
Air pressure (operation) | 795 hPa ... 1080 hPa (up to 2000 m above sea level) |
Air pressure (storage/transport) | 66 kPa ... 108 kPa (up to 3500 m above sea level) |
Ambient temperature (storage/transport) | -25 °C ... 85 °C |
Permissible humidity (operation) | 95 % (non-condensing) |
Permissible humidity (storage/transport) | 95 % |
CE | |
Certificate | CE-compliant |
UL, USA/Canada | |
Identification | 508 Listed |
Wireless approval, Europe | |
Note | RED 2014/53/EU |
Wireless approval USA, FCC | |
Identification | YG3ADIOMUX |
Note | FCC directive, part 15.247 |
Wireless approval India, WPC | |
Certificate | NR-ETA/5957 |
Wireless approval Japan, MIC | |
Identification | Japan MIC (RF) ID:202-LSF002 |
Wireless approval Canada, IC | |
Certificate | 4720B-ADIOMUX |
Note | ISC directive RSS 210 |
Wireless approval Mexico, IFT | |
Certificate | IFT RCPPHIL19-2130 |
Wireless approval South Africa, ICASA | |
Certificate | TA-2006/032 |
KC approval for South Korea | |
Certificate | MSIP-CRI-PCK-2884208 |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Electrostatic discharge | |
Standards/regulations | EN 61000-4-2 |
Electrostatic discharge | |
Contact discharge | ± 6 kV (Test Level 3) |
Discharge in air | ± 8 kV (Test Level 3) |
Indirect discharge | ± 6 kV |
Comments | Criterion B |
Electromagnetic HF field | |
Standards/regulations | EN 61000-4-3 |
Electromagnetic HF field | |
Frequency range | 26 MHz ... 3 GHz (Test Level 3) |
Field intensity | 10 V/m |
Comments | Criterion A |
Fast transients (burst) | |
Standards/regulations | EN 61000-4-4 |
Fast transients (burst) | |
Input | ± 2 kV (Test Level 3) |
Signal | ± 2 kV (Signal line) |
Comments | Criterion B |
Surge current load (surge) | |
Standards/regulations | EN 61000-4-5 |
Surge current load (surge) | |
Input | ± 0.5 kV (symmetrical) |
± 1 kV (asymmetrical) | |
Signal | ± 1 kV (Signal line, asymmetrical) |
Comments | Criterion B |
Conducted interference | |
Standards/regulations | EN 61000-4-6 |
Conducted interference | |
Frequency range | 0.15 MHz ... 80 MHz |
Comments | Criterion A |
Voltage | 10 V |
Emitted interference | |
Emitted radio interference in acc. with EN 55011 | EN 55016-2-3 Class A industrial applications |
Criteria | |
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Protection class | III |
Free from substances that could impair the application of coating | VDMA 24364:2018-05 |
Standard designation | RED directive 2014/53/EU |
Standards/specifications | EN 300328 |
EN 61000-6-4 | |
EN 61000-6-2 | |
EN 62311 | |
EN 60950 |
Mounting type | DIN rail mounting |
Item number | 2884208 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Sales key | DNC662 |
Product key | DNC662 |
Catalog page | Page 386 (C-6-2019) |
GTIN | 4046356049597 |
Weight per piece (including packing) | 914 g |
Weight per piece (excluding packing) | 885 g |
Country of origin | DE |
ECLASS
ECLASS-11.0 | 27242602 |
ECLASS-12.0 | 27242602 |
ECLASS-13.0 | 27242602 |
ETIM
ETIM 9.0 | EC001597 |
UNSPSC
UNSPSC 21.0 | 32151600 |
EU RoHS | |
Fulfills EU RoHS substance requirements | Yes |
Exemption | 6(c), 7(a), 7(c)-I |
China RoHS | |
Environment friendly use period (EFUP) |
EFUP-50
An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required.
|
EU REACH SVHC | |
REACH candidate substance (CAS No.) | Lead (CAS: 7439-92-1) |
SCIP | 82710383-ad84-4f18-bc08-99d7dfd2aa2d |
EF3.0 Climate Change | |
CO2e kg | 22.86 kg CO2e |
Compatible products
-
IB IL SCN 6-SHIELD-TWIN - Inline shield connector 2740245
-
IB IL SCN-PWR IN-CP - Inline connector 2727637
-
IB IL SCN-8 - Inline connector 2726337
-
IB IL FIELD 2 - Marking field 2727501
-
ESL 62X10 - Insert strip 0809492
-
ZBFM 6/WH:UNBEDRUCKT - Flat zack marker sheet 0803618
-
CLIPFIX 35-5 - End bracket 3022276
-
ANT-OMNI-2459-04 - Antenna 1284780
-
RAD-ISM-2400-ANT-OMNI-2-1-RSMA - Antenna 2701362
-
RAD-ISM-2400-ANT-VAN-3-0-RSMA - Antenna 2701358
-
RAD-ISM-2459-ANT-FOOD-6-0-N - Antenna 2702898
-
ANT-OMNI-0671-02 - Antenna 1396318
-
ANT-OMNI-0671-01 - Antenna 1396316
-
RAD-ISM-2400-ANT-OMNI-6-0 - Antenna 2885919
-
ANT-DIR-2459-01 - Antenna 2701186
-
RAD-PIG-EF316-N-RSMA - Antenna cable 2701402
-
RAD-PIG-RSMA/N-0.5 - Antenna cable 2903263
-
RAD-PIG-RSMA/N-1 - Antenna cable 2903264
-
RAD-PIG-RSMA/N-2 - Antenna cable 2903265
-
RAD-PIG-RSMA/N-3 - Antenna cable 2903266
-
RAD-PIG-RSMA/N-5 - Antenna cable 2702140
-
NBC-COX-CNM/3.0-L/COX-CNM - Coaxial cable 1340123
-
NBC-COX-CNM/5.0-L/COX-CNM - Coaxial cable 1340124
-
NBC-COX-CNM/10.0-L/COX-CNM - Coaxial cable 1340125
-
NBC-COX-CNM/15.0-L/COX-CNM - Coaxial cable 1340126
-
NBC-COX-CNM/30.0-L/COX-CNM - Coaxial cable 1340127
-
CN-UB-70DC-6-BB - Surge protection device 2803166
-
RAD-ADP-N/F-N/F - Adapter 2867843
-
RAD-ADP-RSMA/M-RSMA/F-90 - Adapter 2904790
-
RAD-TAPE-SV-19-3 - Weather protection tape 2903182
Your advantages
Wireless diagnostics by means of bar graph
Range of 50 m ... 100 m in industrial halls with omnidirectional antennas and up to 400 m outdoors with directional antennas
Quick connection establishment and signal transmission
Current Bluetooth 4.0 technology
Plug and play - startup without configuration
It couldn't be simpler: unpack – connect – switch on
PHOENIX CONTACT Ltd
Unit 15C, 906-930 Great South Road, Penrose, Auckland 1061, New Zealand