Proxy - FL NP PND-4TX IB
2985974

Proxy for PROFINET-RT-IRT, G4 functionality, INTERBUS proxy with integrated 4-port switch

Downloads

Product Details


The latest generation of INTERBUS proxies seamlessly integrate a complete INTERBUS system together with all its functions into a higher-level control system with PROFINET functionality. Using GSDML files, the parameterization can be integrated perfectly into the higher-level engineering system.

The devices offer the following features:
- Data exchange, diagnostics, and parameterization are via the PROFINET protocol
- They can be integrated and parameterized in any controller using the PROFINET functionality
- LLDP support for topology detection
- PROFINET update rates ≥ 1 ms



Type Stand-alone
Product type Gateways/Proxies

Maximum power dissipation for nominal condition 8.4 W
Supply
Supply voltage 24 V DC
Supply voltage range 18.5 V DC ... 30.2 V DC
Power supply connection Via COMBICON, max. conductor cross section 2.5 mm²
Residual ripple 3.6 VPP (within the permitted voltage range)
Typical current consumption typ. 350 mA

Ethernet
Connection method RJ45 jack
Transmission speed 10/100 Mbps
Transmission length 100 m
No. of channels 4
INTERBUS (Master)
Bus system INTERBUS
Connection method 9-pos. D-SUB socket
Transmission speed 500 kbps / 2 Mbps (can be switched)
No. of channels 1

INTERBUS-Master
Amount of process data 512 words
Number of supported devices max. 512 (Depending on the control class and data direction)
Number of devices with parameter channel max. 126 (512 words)
INTERBUS-Slave
Amount of process data 512 words
Number of PCP words 512 words

Status display 7-segment display/ diagnostics LEDs

Functionality
Number of I/O nodes 8192

Width 128 mm
Height 95 mm
Depth 69 mm

Ambient conditions
Degree of protection IP20
Ambient temperature (operation) -25 °C ... 60 °C
Ambient temperature (storage/transport) -25 °C ... 70 °C
Permissible humidity (operation) 10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing)
Vibration (operation) 5g, accordance to IEC 60068-2-6
Air pressure (operation) 80 kPa ... 108 kPa (2000 m above sea level)
Air pressure (storage/transport) 66 kPa ... 108 kPa (3000 m above sea level)

Conformance with EMC directives Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, all interfaces 1 kVCriterion B, all interfaces 2 kV
Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, supply lines DC: 0.5 kV/0.5 kV (symmetrical/asymmetrical), fieldbus cable shield 1 kV
Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
Noise emission test in accordance with EN 61000-6-4/IEC 61000-6-4 EN 55011 Class A
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU

Mounting type DIN rail mounting

Item number 2985974
Packing unit 1 pc
Minimum order quantity 1 pc
Sales Key DREBAA
Product Key DREBAA
Catalog Page Page 358 (C-6-2019)
GTIN 4046356168939
Weight per Piece (including packing) 770.8 g
Weight per Piece (excluding packing) 737.6 g
Customs tariff number 85176200
Country of origin DE


ECLASS

ECLASS-9.0 19170103
ECLASS-10.0.1 19170405
ECLASS-11.0 19170405

ETIM

ETIM 8.0 EC001478

UNSPSC

UNSPSC 21.0 43222600

EAC

Approval ID: RU*DE*08.B.00731/19

UL Listed

Approval ID: FILE E 140324

cUL Listed

Approval ID: FILE E 140324

cULus Listed


REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads”

Your advantages

PROFINET update rates = 1 ms
Can be integrated and parameterized in any controller using the PROFINET functionality
Data exchange, diagnostics, and parameterization are via the PROFINET protocol
LLDP support for topology detection