Temperature measuring transducer - MACX MCR-EX-TS-I-OLP
2908660

Ex i, Output loop-powered temperature transducer for transmitting up to 2 sensor signals from RTD and TC sensors, as well as from resistance and voltage sensors via 4 mA ... 20 mA. HART, Standard configuration, Safety Integrity Level (SIL, IEC 61508): 2, Systematic Capability: 3, Screw connection

Downloads

Product Details




Product type Temperature transmitter
Type Ex i signal conditioners with SIL functional safety
Insulation characteristics
Overvoltage category II
Pollution degree 2

Step response (0–99%) 0.8 s (TC)
Electrical isolation Input/output
Test voltage 2 kV AC (50 Hz, 60 s)
Supply
Supply voltage range 12 V DC ... 42 V DC (Standard)
12 V DC ... 32 V DC (SIL active)
12 V DC ... 30 V DC (Ex)

Signal
Input signal Temperature
Measurement
Number of inputs 2
Input voltage range -20 mV ... 100 mV
Sensor types (RTD) that can be used Pt, Ni, Cu sensors: 2, 3, 4-wire
Sensor types that can be used (TC) A, B, C, D, E, J, K, L, N, R, S, T, U
Temperature measuring range -250 °C ... 2500 °C (Range depending on the sensor type)
-200 °C ... 850 °C (Pt 100)
Temperature measuring range > 10 K (RTD)
> 50 K (TC)
Linear resistance measuring range 10 Ω ... 2000 Ω (Minimum measuring span: 10 Ω)

Signal: Current
Output name Current output
Configurable/programmable no
Current output signal 4 mA ... 20 mA
20 mA ... 4 mA
Max. current output signal 23 mA
Load (UL - 11 V) / 0,023 A
HART coding FSK ± 0.5 mA
HART version 7
Transmission speed 1200 Baud
Mains frequency filter 50/60 Hz
Communication resistance ≥ 250 Ω
Switch-on delay  10 s (HART)
 28 s (Measured value)

Connection method Screw connection
Stripping length 7 mm
Screw thread M3
Conductor cross section solid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 14
Torque 0.5 Nm ... 0.6 Nm

Data communication (bypass)
Protocols supported HART

Width 12.5 mm
Height 112.5 mm
Depth 113.7 mm
114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715)

Ambient conditions
Degree of protection IP20 (not assessed by UL)
Ambient temperature (operation) -40 °C ... 85 °C
-40 °C ... 70 °C (SIL active)
Ambient temperature (storage/transport) -40 °C ... 100 °C
Altitude ≤ 4000 m (Above sea level)
Climatic class B2
Permissible humidity (operation) 5 % ... 95 % (non-condensing)

CE
Certificate CE-compliant
CE
Identification  II 2 (1) G Ex ib [ia Ga] IIC T6...T4 Gb
Certificate EPS 17 ATEX 1 130 X
CE
Identification Ex ib [ia Ga] IIC T6...T4 Gb
Certificate IECEx EPS 17.0076X
CE
Identification UL 61010 Recognized
CE
Identification Exia / Class I / Div. 1, 2 / Group ABCD
NI, Class I, Div. 2, Groups A, B, C, D
CE
Identification AIS / Class I / Div. 1 / ABCD
NI / Class I / Div. 2 / ABCD T6/T5/T4
CE
Certificate DNV GL TAA00002GX
CE
Identification 2
CE
Identification 3
DNV GL data
Temperature D
Humidity B
Vibration A
EMC B
Enclosure A

Mounting type DIN rail mounting

Item number 2908660
Packing unit 1 pc
Minimum order quantity 1 pc
Note Made to Order (non-returnable)
Sales Key CK3
Product Key CK3322
Catalog Page Page 190 (C-5-2019)
GTIN 4055626355429
Weight per Piece (including packing) 208 g
Weight per Piece (excluding packing) 208 g
Customs tariff number 85437090
Country of origin DE


ECLASS

ECLASS-9.0 27210129
ECLASS-10.0.1 27210129
ECLASS-11.0 27210129

ETIM

ETIM 8.0 EC002919

UNSPSC

UNSPSC 21.0 41112100

cUL Recognized

Approval ID: FILE E 198586

UL Recognized

Approval ID: FILE E 198586

DNV GL

Approval ID: TAA00002GX

Functional Safety

Approval ID: Z10 029429 0021

IECEx

Approval ID: IECEx EPS 17.0076X

CSA

Approval ID: 70107976
X

ATEX

Approval ID: EPS 17 ATEX 1 130 X

FM approved

Approval ID: FM17US0110X

cULus Recognized


REACh SVHC Lead 7439-92-1
China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values